NQ5000P S L9TN Intel, NQ5000P S L9TN Datasheet - Page 386

no-image

NQ5000P S L9TN

Manufacturer Part Number
NQ5000P S L9TN
Description
Manufacturer
Intel
Datasheet

Specifications of NQ5000P S L9TN

Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant
Table 5-31. Intel 5000P Chipset Error List (Sheet 6 of 7)
386
M10
M11
M12
M13
M14
M15
in MCH
ERR #
Non-Aliased
Uncorrectable
Mirrored
Demand Data
ECC Error
Non-Aliased
Uncorrectable
Spare-Copy
Data ECC Error
Non-Aliased
Uncorrectable
Patrol Data
ECC Error
Non-Retry or
redundant FB-
DIMM Memory
Alert, or
redundant fast
reset time-out
Non-Retry FB-
DIMM
Configuration
Alert
Non-Retry FB-
DIMM
Northbound
CRC error on
read data
Error Name
In mirrored mode, the MCH
detected uncorrectable or
poisoned data with good
CRC.
The MCH detected
uncorrectable data with
good CRC from the failing
DIMM rank during a sparing
copy.
During a patrol scrub, the
MCH detected uncorrectable
data with good CRC.
The MCH detected an
“Alert” or corrupted write
acknowledgement on the
first attempt at an FB-DIMM
memory access packet or
on the replay of a
redundant FB-DIMM
memory access packet.
The MCH detected an
“Alert” or corrupted write
acknowledgement on the
first attempt at an FB-DIMM
configuration write
command or on the replay
of a redundant FB-DIMM
configuration write
command
The MCH detected a
northbound CRC error on
the first attempt at a
configuration or memory
read or on the replay of a
redundant configuration or
memory read.
Definition
Intel® 5000P/5000V/5000Z Chipset Memory Controller Hub (MCH) Datasheet
Error
Type
Rec
Rec
Rec
Rec
Rec
Rec
FERR_NF_FBD
NERR_NF_FBD
RECMEM
UERRCNT
FERR_NF_FBD
NERR_NF_FBD
RECMEM
UERRCNT
FERR_NF_FBD
NERR_NF_FBD
RECMEM
UERRCNT
FERR_NF_FBD
NERR_NF_FBD
RECMEM
FERR_NF_FBD
NERR_NF_FBD
CFGLOG
FERR_NF_FBD
NERR_NF_FBD
RECFBD
Log Register
First redundant read to
branch X fails.
MCH performs a fast reset on
both branches X and Y.
If both branches pass, then
replay on branch Y.
If branch X fails the disable
branch X and replay on
branch Y.
If both branches fail or
branch Y fails disable branch
X and poison data. Under
these conditions we get an
M1 error.
Second redundant read to
branch X fails with an
uncorrectable error.
Perform fast reset and
disable branch X and replay
on branch Y
Re-read once.
If ECC is uncorrectable with
good CRC after re-read, then
poison the data in the spare
DIMM or the off-line branch.
If correctable after re-read,
then correct the data in the
spare DIMM or the off-line
branch.
Does not include poisoned
northbound data.
The patrol read is dropped.
Non-redundant or 1st
attempt: Fast reset and
Initiate replay.
Redundant replay or fast
reset time-out: auto-
degrade.
1st attempt: Fast reset and
Initiate replay.
Redundant replay: auto-
degrade.
1st redundant memory read:
re-read once from other
image.
Replay redundant memory
read: auto-degrade
All others: fast reset and
initiate replay from the same
image, branch, or channel.
Functional Description
Cause / Actions

Related parts for NQ5000P S L9TN