BZ-2RW824-A2 Honeywell, BZ-2RW824-A2 Datasheet

Basic / Snap Action / Limit Switches Snap Action NO/NC SPDT 15A 0.7N

BZ-2RW824-A2

Manufacturer Part Number
BZ-2RW824-A2
Description
Basic / Snap Action / Limit Switches Snap Action NO/NC SPDT 15A 0.7N
Manufacturer
Honeywell
Series
BZ seriesr
Type
Basicr
Datasheets

Specifications of BZ-2RW824-A2

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Actuator Style
Lever
Current Rating (max)
15A
Terminal Type
Screw
Product Depth (mm)
17.5mm
Operating Force
0.7N
Contact Form
SPDT
Contact Rating
15 Amps
Actuator
Lever
Termination Style
Screw
Actuator Type
Lever
Brand/series
BZ Series
Current, Rating
15/0.5 AAC/ADC
Mounting Hole Size
0.14 "
Number Of Poles
1
Number Of Positions
2
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
-32 to +71 °C
Termination
Screw
Voltage, Rating
600/250 VAC/VDC
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BZ-2RW824-A2
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
Basic Switches
SUBMINIATURE/MINIATURE BASIC SWITCHES
The U Series of subminiature basic switches are our newest line. The US is the
smallest snap-action switch available. The UX and UM are versatile, low cost,
full featured products with ample electrical capacity in a compact package.
SM subminiature basic switches are a versatile collection of small size and
ample electrical capacities, including 11 amp power load handling and
motor load. SX subminiature basic switches are smaller than SM switches,
yet are big in performance and selection. They provide up to 7 amp power
load capacity. V3 miniature basic switches put a 25 amp power load capacity
and a choice of 11 other electrical ratings into a relatively small package with
many choices of actuators, contact materials, and terminal designs. V7 minia-
ture basic switches have electrical ratings up to 15 amps. Both commercial
and European versions are UL recognized and CSA certified. The latter is also
designed to meet all leading European approval agency requirements. TB
miniature basic small double-break units can control 2, 3 or 4 isolated circuits.
STANDARD BASIC SWITCHES
Power load switching and motor handling capacity are among the attractions
of thumb-size BZ/BA standard basic switches. Double-pole double-throw
switching is added by DT switches. Where there’s a need for reliable switch-
ing of high capacity systems involving DC motors and solenoids, MT magnet-
ic blow-out switches do the job. The 3MN has double-break switching. 6AS
assemblies have two tandem mounted standard basic switches under a com-
mon actuator.
SEALED AND HIGH TEMPERATURE BASIC SWITCHES
Specially adapted basic switches include: SE/XE environment-proof switch-
es which protect subminiature SM/SX basic switches within a sealed hous-
ing; HM hermetically sealed switches are interchangeable in operating point
with the SM switches; HS hermetically sealed switches which parallel the size
and mounting scheme of the standard basic switches; and HT high temper-
ature switches for use up to 1000 F.
DOOR SWITCHES
AC, WW and DM switches automatically cut power when a service door or
drawer is opened.
For application help: call 1-800-537-6945.
Sealed/High Temperature Switches
Door Switches
1
4
hp
Honeywell Sensing and Control
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . p. 2
Index by Product Type . . . . . . . . . . . . . . . . . . . . . p. 3
Selection Guides. . . . . . . . . . . . . . . . . . . . . . p. 4 to 7
Catalog Listings/Order Guides . . . . . . . . . p. 8 to 93
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . p. 94
Catalog Listing/Page Number Index . . . . . . . p. 102
Miniature/Subminiature Switches
Standard Basic Switches
1

Related parts for BZ-2RW824-A2

BZ-2RW824-A2 Summary of contents

Page 1

... STANDARD BASIC SWITCHES Power load switching and motor handling capacity are among the attractions of thumb-size BZ/BA standard basic switches. Double-pole double-throw switching is added by DT switches. Where there’s a need for reliable switch- ing of high capacity systems involving DC motors and solenoids, MT magnet- ic blow-out switches do the job ...

Page 2

... Hz (sea level) 20 Honeywell Sensing and Control Circuitry Electrical Data Single-pole S UL rating: double-throw 4 amps, 250 vac. ...

Page 3

... I 10 amps, 125, 250 or 480 vac; double-throw 1 ⁄ hp, 125 vac; 8 unless UL Code L95 otherwise noted in order guide 46 Honeywell Sensing and Control Circuitry Double-pole double-throw Single-pole double-throw unless otherwise noted in order guide *To polarize, connect negative side of line to common terminal ⁄ hp, 250 vac; ...

Page 4

... IN-LINE PLUNGER ACTUATION 94 Honeywell Sensing and Control Free Position (F.P .)—Position of switch plunger or actuator when no external force is applied (other than gravity). Full Overtravel Force—Force required to attain full overtravel of actuator. Operating Position (O.P .)— ...

Page 5

... Honeywell Sensing and Control Direct Current 230 Volts Locked Full Locked Rotor Load Rotor 170.0 8.5 85.0 132.0 6.6 66.0 96.0 4.8 48.0 74 ...

Page 6

... BZ-1R 125 15 15 .010 in. 250 15 15 0,25 mm 277 15 15 460 15 15 *Ampere levels for BZ-3YT applicable only if common terminal is not used and switch is used as a shorting bar switch. 96 Honeywell Sensing and Control Inrush Motor N.C. N.O. N.C. N.O. Ckt. Ckt. Ckt ...

Page 7

... VAC BZ-3R 125 15 15 .036 in. 250 15 15 0,91 mm 277 15 15 460 15 15 VDC BZ- .070 in 1, 125 15 0.75 250 15 0.3 VAC BZ-7R 120 15 15 .070 in. 240 15 15 1,78 mm 277 15 15 460 For (30 C) max. temperature rise at terminals, not opening or closing the load (at sea level). ...

Page 8

... Dead break is expressed in distance of plunger travel during which the non-contact occurs. Manufacturing specifications for most BZ/BA basic switches allow a maximum dead break of 0.00005 in. (0,001 mm) measured at the switch plunger. Switches are evaluated while moving the plunger with the switch installed VDC, 0 ...

Page 9

... Basic Switches Subminiature PC Terminal Version FEATURES MICRO SWITCH’S smallest snap-action switch Choice of low energy or power duty electrical ratings Variety of integral actuators Temperature Range 176 F) Weight: 0.2 grams (.007 oz.) – PC terminal type 0.3 grams (.011 oz.) – solder terminal type Form C single-pole double-throw (SPDT) circuitry ORDER GUIDE SOLDER TERMINALS O ...

Page 10

... Pin plunger (Type A) Left angle terminal (Type 60) Mounting screw size is m 1,4. Maximum tightening torque is 1 kg-cm. For application help: call 1-800-537-6945. Flat lever (Type C) Simulated roller (Type E) Right angle terminal (Type 50) Flat lever (Type C) Simulated roller (Type E) Honeywell Sensing and Control US Series 9 ...

Page 11

... E roller lever 55 simulated 1.94 OTHER TERMINATION TYPES ARE AVAILABLE For PC right angle, change 2nd set of numbers to 50 (Example: UX10C50A01) For PC left angle, change 2nd set of numbers to 60 (Example: UX10C60A01) 10 Honeywell Sensing and Control ELECTRICAL RATINGS (in amps) Voltage 125 VAC* 30 VDC 6 VDC ...

Page 12

... Flat lever (Type C) Mounting screw size is 2 mm. Maximum tightening torque is 1 kg-cm. For application help: call 1-800-537-6945. in. PC board terminals – Type 30 PC board mounting Type 50 Simulated Roller Lever (Type E) Honeywell Sensing and Control UX Series Type 60 11 ...

Page 13

... D flat lever 12 26mm .4 25 .88 45 1.6 12 Honeywell Sensing and Control NC ELECTRICAL RATINGS (in amps) UM50E Silver Contacts Voltage Resistive Inductive 125 VAC 5 3 250 VAC VDC 5 3* *Time constant for DC inductive loads: less than 7 msec. UL File No. E12252, CSA File LR23413M167 R ...

Page 14

... UM10D10H01 UM10D70H01 3,0 .106 UM10E10H01 UM10E70H01 3,5 .123 UM10B10F01 UM10B70F01 1,7 .060 UM10D10F01 UM10D70F01 3,5 .123 UM10E10F01 UM10E70F01 4,0 .141 Honeywell Sensing and Control UM Series O.T. min. D.T. max. O inches inches inches inches 8,5 2,2 2,5 8,8 2,4 .335 .087 .098 ...

Page 15

... For PC Straight international, change 2nd set of numbers to 40 (Example: UM40B40A01) For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM40B50A01) For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM40B60A01) 14 Honeywell Sensing and Control R.F. min. P .T. max. Terminals ...

Page 16

... PC Straight Cross-Line – Type 20 PC Left Angle In-line – Type 60 20mm Flat Lever Type C 18mm Roller Lever Type F 5mm (.197 in.) dia. x 3,2mm (.126 in.) thick roller Honeywell Sensing and Control UM Series PC Straight In-line – Type 40 QC Quick Connect – Type 70 26mm Flat Lever Type D 60mm Type J ...

Page 17

... Form C single-pole double-throw Temperature range 185 F) Weight, approx.: .07 oz. (2g.) for IP50-sealed switches; and .14 oz. (4g.) for IP67-sealed switches, not including leadwires UL, CSA, VDE, and SEMKO marking designations 16 Honeywell Sensing and Control IP67-SEALED ELECTRICAL RATINGS (in amps) Silver Contacts Voltage Resistive Inductive 125 VAC 2.0 2.0 250 VAC 2 ...

Page 18

... UM35E71CS1 3,5 2,8 .123 .110 UM35E71DS1 3,0 3,5 .106 .138 UM35E71ES1 3,5 2,8 .123 .110 UM35E71FS1 4,0 2,5 .141 .098 Honeywell Sensing and Control UM Series O.T. min. D.T. max. O inches inches inches 0,4 0,1 8,4 0,3 .016 .004 .331 .012 0,8 ...

Page 19

... F roller 60 UM10E90FS1 lever 2.1 MOUNTING DIMENSIONS Mounting screw size is m 2,3 (For reference only) mm Maximum torque is 3 kg/cm. in. Pin Plunger Type A PC Terminals 18 Honeywell Sensing and Control R.F. min. P .T. max. O.T. min. grams mm ounces inches inches UM35E90AS1 20 0,6 .705 .024 ...

Page 20

... Lever Actuators 4 mm/.158 in. wide 18 mm Flat Lever Type Flat Lever Type Flat Lever Type D For application help: call 1-800-537-6945 Simulated Roller Lever Type E 2,5 mm radius 18 mm Roller Lever Type F 5 mm/.197 in. dia. x 3,2 mm/.126 in. Thick Roller Honeywell Sensing and Control UM Series Leadwires 19 ...

Page 21

... Mounting torque Round head 2-56 UNC 438 screws— 2 inch pounds max. H391, H392 STRAIGHT PIN 90 FORMED PIN Honeywell Sensing and Control SX Series FEATURES Low operating force to 3 oz. (85 grams) maximum Sensitive differential travel as low as .001 inch maximum Power load switching capability amperes— ...

Page 22

... MIL-S-8805 application (MS24547-1) requirements 21SX39-T2 MIL-S-8805 application (MS24547-4) requirements 91SX39-T .156 wide version M8805/109-01 of standard SX ( Honeywell Sensing and Control Electrical Data and O.F. max. R.F. min. P .T. max. O.T. min. D.T. max. UL Code newtons newtons Page 20 ounces ounces At 1,39 0,28 Left 5 ...

Page 23

... A 2.1 .39 1 Amp 0,58 0,11 D 2.1 .39 5 Amps 0,31 0,05 A 1.1 .18 1 Amp 0,31 0,05 D 1.1 .18 Honeywell Sensing and Control SX Series O inches inches inches inches 1,65 0,36 0,51 8,43 1,14 .065 .014 .020 .332 .045 1,65 0,36 0,51 8,43 1,14 ...

Page 24

... Honeywell Sensing and Control Characteristics: O.F. – Operating Force; R.F. – Release Force; P .T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P . – Operating Position; F.P . – Free Position. ...

Page 25

... Switches are not included with actuator. For application help: call 1-800-537-6945. Fig. 2 Fig. 5 Fig. 8 Fig. 9 Mounting holes accept pins or screws of .087 diameter (2,21 mm). Honeywell Sensing and Control SX Series INTEGRAL LEVERS Dim. ‘‘A’’ 311SX1-T 3,6/.14 311SX2-T 13,0/.51 Fig. 3 Interchangeable with 1SX-1T switch with JX-25 actuator ...

Page 26

... This section covers only 38 of our most popular SM Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 500 other active SM listings will meet your needs. Contact the 800 number. 26 Honeywell Sensing and Control GENERAL INFORMATION SM subminiature switches are slightly larger than the SX switches ...

Page 27

... Amps 0,83-2,09 0,28 0,51 0,13 K 3-7.5 1 .020 .005 1 Amp 0,83-2,09 0,28 0,51 0,13 N 3-7.5 1 .020 .005 Honeywell Sensing and Control SM Series O inches inches 0,1 8,38 .004 .330 0,1 8,38 .004 .330 0,1 8,38 .004 .330 0,1 8,38 .004 .330 ...

Page 28

... Dim. Dwg. Fig Honeywell Sensing and Control Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position. Electrical Data And O.F. max. R.F. max. P .T. max. O.T. min. D.T. max. ...

Page 29

... Amp 1,95 0,56 5, .218 5 Amps 1,95 0,56 5, .219 1 Amp 1,95 0,56 5, .219 Honeywell Sensing and Control SM Series O inches inches inches 0,76 0,76 8,89 0,76 .030 .030 .350 .030 0,76 0,76 8,89 0,76 .030 .030 .350 .030 0,76 0,64 14,3 0,76 .030 ...

Page 30

... See page 79 for other actuators that may be used with SM Switches at higher temperatures. †‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing. 30 Honeywell Sensing and Control Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . ...

Page 31

... INTEGRAL LEAFS Fig. 11 AUXILIARY ACTUATORS Fig. 14 Switches are not included with the actuators. For application help: call 1-800-537-6945. Fig. 2 Fig. 5 Fig. 6 Fig. 9 Mounting holes accept pins or screws of .087 inch (2,21 mm) max. diameter Fig. 12 Fig. 16 Honeywell Sensing and Control SM Series Fig. 7 Fig ...

Page 32

... Lower force 12SE4-T High return force 1SE1-T For customer leading Fig. 2 Honeywell Sensing and Control 1-800-537-6945 USA GENERAL INFORMATION SE and XE switches are the smallest envi- ronment-sealed switches offered by MICRO SWITCH. Both types enclose ba- sic switches within a corrosion resistant aluminum housing to seal precision switch contacts from contamination ...

Page 33

... JE-22 Tandem Roller Lever Fig Honeywell Sensing and Control 1-800-537-6945 USA Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position Characteristics measured with actuators mounted to a 1SE1 Actuator O ...

Page 34

... Listing Description JM-1 Straight leaf Fig. 11 JM-5 Roller leaf Fig. 12 Honeywell Sensing and Control 1-800-537-6945 USA Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; D.T. — Differential Travel; O.P . — Operating Position. Characteristics O.F. R.F. P .T. Electrical max ...

Page 35

... Position Sensors Environment-Sealed Basic Switches SE MOUNTING DIMENSIONS (For reference only) SE switches MOUNTING HOLES WILL ACCEPT PINS OR SCREWS OF 22,1/.087 MAX DIA Fig auxiliary actuators Fig. 3 Fig Honeywell Sensing and Control 1-800-537-6945 USA Fig. 2 Fig. 4 Fig. 7 1-815-235-6847 International 1-416-293-8111 Canada SE Series Fig. 5 Fig. 8 ...

Page 36

... Position Sensors Environment-Sealed Basic Switches XE MOUNTING DIMENSIONS (For reference only) XE switches Fig auxiliary actuators Fig. 11 Honeywell Sensing and Control 1-800-537-6945 USA Fig. 10 Fig. 12 1-815-235-6847 International 1-416-293-8111 Canada XE Series 17 ...

Page 37

... Hz UL-CSA Rating: 1 amp., 115 vac, 60 Hz. 22 Honeywell Sensing and Control 1-800-537-6945 USA GENERAL INFORMATION HS switches are designed for applications where maximum electrical rating and max- imum sealing are essential, and where size and weight requirements are less critical ...

Page 38

... HS MOUNTING DIMENSIONS (For reference only) Mounting holes will accept pins or screws of .139 (3,53mm) diameter. Fig. 1 Fig. 4 Honeywell Sensing and Control 1-800-537-6945 USA Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position. ...

Page 39

... VAC, 400 Hz. APPLICATION NOTES 1. Honeywell does not recommend the use of silver cadmium oxide switch con- tacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. Catalog listings in the 5, 6, 15, and 16HM Series use silver cadmium oxide contacts. If you have specific questions, contact the MICRO SWITCH Application Center at 1-800-537-6945 ...

Page 40

... The force spreading mounting plate used as shown will allow up to 2.5 inch pounds of mounting torque. Honeywell Sensing and Control 1-800-537-6945 USA Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; ...

Page 41

... See optional mounting plate – previous page. 20 Honeywell Sensing and Control 1-800-537-6945 USA Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P . — Operating Position; F.P . — Free Position. ...

Page 42

... Miniature Hermetically Sealed Switches HM MOUNTING DIMENSIONS (For reference only) Pin plunger switches Fig. 1 MOUNTING HOLES WILL ACCEPT PINS OR SCREWS OF 1,9/.08 DIA Fig. 3 Auxiliary actuators Fig. 5 Fig. 7 Honeywell Sensing and Control 1-800-537-6945 USA Fig. 2 Fig. 4 Fig. 6 Fig. 8 1-815-235-6847 International 1-416-293-8111 Canada HM Series 21 ...

Page 43

... Fig MOUNTING DIMENSIONS (For reference only) Fig. 1 Mounting holes will accept pins or screws of .139 (3,53 mm) dia. 24 Honeywell Sensing and Control 1-800-537-6945 USA GENERAL INFORMATION HT switches will withstand temperatures up to 1000F. The switching element is mounted on a ceramic base within a stainless steel enclosure. HT switches are not classified as sealed switches ...

Page 44

... ORDER GUIDE Catalog Listing MT-4R-A28 Pin plunger SPDT Dim. Dwg. Fig Honeywell Sensing and Control FEATURES Arc resistant case Mechanical life of 100,000 operations — 95% survival Temperature tolerance to 180 F (82 C) Mounting interchangeability with Z switches UL recognized ...

Page 45

... Amps 0,76 0,07 K 2.75 0.25 10 Amps 1,25 0, Amps 3,34 0, Amps 3,34 0, Honeywell Sensing and Control MT Series P.T. max. O.T. min. D.T. max. O.P inches inches inches inches 12,7 1,19 2,16 19,1 0.5 .047 .085 .750 8,89 0,79 1,65 30,2 0 ...

Page 46

... Magnetic Blow-out MOUNTING DIMENSIONS (For reference only) PIN PLUNGER Fig. 1 ROLLER LEVER Fig. 3 FLEXIBLE ROLLER LEAF Fig. 5 Mounting holes accept pins or screws of .139 (3,53 mm) diameter. 72 Honeywell Sensing and Control STRAIGHT LEVER Fig. 2 FLEXIBLE LEAF Fig. 4 For application help: call 1-800-537-6945. MT Series ...

Page 47

... This section covers only 60 of our most popular V3 Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 850 other active V3 listings will meet your needs. Contact the 800 number. 32 Honeywell MICRO SWITCH Sensing and Control Obsolete There is a choice of SPDT, SPNC, and SPNO circuitry ...

Page 48

... Amps 32,6 0,33 V 1.285 1.2 11 Amps 32,6 1,11 T 1.285 15.1 Amps 32,6 2,22 U 1.285 15.1 Amps 32,6 0,94 U 1.285 3.4 Honeywell V3 Series R.F. P.T. O.T. min. max. min. D.T. O.P.** inches inches inches inches 0,56 1,2 1,02 0,15-0,41 14,7 2 ...

Page 49

... V3L-2472-D8 V3L-1124-D8 V3L-145-D8 Dim. Dwg. Fig. 4 V3L-14-D8 34 Honeywell MICRO SWITCH Sensing and Control Obsolete Characteristics: O.F. – Operating Force; R.F. – Release Force; P .T. – Pre- travel; O.T. – Overtravel; D.T. – Differential Travel; O.P . – Operating Posi- tion. Electrical Length of O.F. Data And Lever ‘ ...

Page 50

... Honeywell V3 Series P .T. max. O.T. min. D.T. max. O inches inches inches inches 1,2 1,14 0,33 20,6 0,76 .047 .045 .013 .810 .030 1,42 0,86 0,33 20,6 0,76 ...

Page 51

... Travel characteristics on tandem actuators vary with actual basic switch characteristics. These shown are typical for the assembly. † ‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing. Dim. Dwg. Fig Honeywell MICRO SWITCH Sensing and Control Obsolete Characteristics: O.F. — Operating Force; R.F. — Release Force; P .T. — Pretravel; ...

Page 52

... MOUNTING DIMENSIONS (for reference only) PIN PLUNGERS Fig. 1 SIMULATED ROLLER Fig. 3 AUXILIARY ACTUATORS Fig. 11 Fig. 17 For application help: call 1-800-537-6945. Obsolete STRAIGHT LEVER Fig. 4 NOTE: Operate point dimensions taken at top of lever/roller. Honeywell V3 Series Fig. 2 ROLLER LEVER Fig. 7 Fig. 14 MICRO SWITCH Sensing and Control 37 ...

Page 53

... APPROVALS (QC ) CE, CSA, ENEC Type SPDT P I 35,6 15 APPROVAL S CE, ENE C High temperature Type 59, 5 APPROVAL S CE, ENEC Honeywel l www .honeywell .com/sensing 20 .P. ) APPROVALS CE, CSA, ENEC. UL High temperature REFERENCE CE, CSA . ENEC. UL V5CO10BB3B Type (P APPROVALS REFERENC CSA, ENEC . UL Lever position 2 V5B210CB1 C CE ...

Page 54

... Therefore, these products are suitable for secondary circuit use but not primary circuit use which requires a 3mm gap. 38 Honeywell Sensing and Control CUTAWAY V7 MINIATURE BASIC SWITCH GENERAL INFORMATION The V7 Series is available in two versions, the Timesaver series and the International series ...

Page 55

... V7 listings will meet your needs. Contact the 800 number. For application help: call 1-800-537-6945. E8 .187 Wide .020 Thick * International approving agencies will require that switches with these terminals have insulated re- ceptacles or connector. PO1 PO7 Honeywell Sensing and Control V7 Series E9 .250 Wide .032 Thick 39 ...

Page 56

... NOTE: Catalog listings in V7 Order Guides have standard .114 mounting holes. For 3mm size holes, contact the 800 number. 40 Honeywell Sensing and Control Characteristics: O.F. – Operating Force; R.F. – Release Force; P .T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel. ...

Page 57

... C 3 .32 21 Amps 100 7 V 3.5 .25 Catalog Listing 15PA177-V7 Insulator packet (500 pcs.) .018 thick varnished fiberglass. Dimensions shown are for reference only. Honeywell Sensing and Control V7 Series O.T. min. D.T. max inches inches inches 2,79 1,9 0,76 .110 .075 .030 2,79 ...

Page 58

... NOTE: Catalog listings in V7 Order Guides have standard .114 mounting holes. For 3mm size holes, contact the 800 number. Dim. Dwg. Fig Honeywell Sensing and Control Characteristics: O.F. – Operating Force; R.F. – Re- lease Force; P .T. – Pretravel; O.T. – Overtravel; D.T. – Dif- ferential Travel. ...

Page 59

... NOTE: All levers are 0.17 (4,31 mm) wide. Rollers are 0.19 (4,82 mm) wide. NOTE: Operate point dimensions taken at top of lever/roller. For application help: call 1-800-537-6945. Fig. 3 Simulated Roller (Style-263) Fig. 6 Straight Lever (Style-048) Honeywell Sensing and Control V7 Series Fig. 4 Roller Lever (Style-201) Fig. 7 Roller Lever (Style-207) 43 ...

Page 60

... Straight /ever 125/250 Va c Quick connect, solder Gold or silve r SPDT UL/ 10.1 A TERMINATION Quick connect Solder Simulated roller lever 55-53 REFERENC E TERMINATION ZM50E70AO 1 Quick connec t ZM50E1OA0 1 Solder ZM90G2OAO 1 ZM10BI0A01 Honeywell www.honeywell .com/sensin .346 0.287 0. 5 200 0.374 0.205 ELECTRICAL RATIN G ...

Page 61

... D.191 dra 00098 1. 6 8.8 0.4 0.063 0.374 .200 5.8 0 .22 8 REFERENCE TERMINATIO N ELECTRICAL RATING ZX40E30001 ZX40E10001 Solde Quick connect Honeywel l BASIC SWITCHES .114 — . .081 112 5 .08 424 - .049 0228 ELECTRICAL RATING CONTACT TYP E ...

Page 62

... Solder 6. 4 0.252 3.55 0.140 Straight lever I II 90 0.126 REFERENC E ZV50E20FO1 ZV50E70FO1 520 0 .205 TERMINATION Solder Honeywel l www.honeywell .com/sensin Aor5A 0 . .4C 0 .295 094 .3/ 4 19. 8 0.780 ELECTRICAL RATING CONTACT TYPE REFERENC E silve r ZW50F15AD1 . 0.780 ELECTRICAL RATING CONTACT TYPE REFERENC E ...

Page 63

... Roller leve r CON : BLACK NO,CYAN ° .205 0.37 4 19. 8 0.11830 .020 ° 0 .780 I TERMINATION ELECTRICAL RATING CONTACT TYP E Wire leads 0 NC_ 6 .4 0.252 REFERENCE gold ZW10E90FW 1 Honeywel l www.honeywell .com/sensing m ...

Page 64

... Dim. Dwg. Fig. 3 Four-circuit, double- 41TB5-3 break front solder terminals Dim. Dwg. Fig Honeywell Sensing and Control FEATURES Power load switching capability amperes Motor handling capacity of 1 ⁄ horse- 2 power, 125 VAC Two- and four-circuit double-break ...

Page 65

... For use with 1TB1-1 and 1TB1-2 switches JT-1 JT-5 Switches are not included with the actuators. MOUNTING DIMENSIONS (For reference only) Fig. 1 Fig. 3 For application help: call 1-800-537-6945. ORDER GUIDE Catalog Listing JT-1 Leaf actuator JT-5 Roller leaf actuator Honeywell Sensing and Control TB Series Description Fig. 2 Fig ...

Page 66

... UL/CSA Our basic switches are Component Recognized by Underwriters’ Laboratories, Inc. and certified by Canadian Standards Associ- ation. The BA, BZ, and BM line is covered as Special Use Switches to UL Standard 1054; the BE line is covered as an Industrial Motor Controller to UL Standard 508. Agency File References ...

Page 67

... Basic Switches Standard AVAILABLE TERMINALS Most of the BZ/BA catalog listings have A2 type terminals. Several other terminal styles are shown and others are available. Specific information should be requested from the 800 number or local Authorized Distributor. Solder (No suffix) A2 Use up to #14 wire Bottom facing 6-32 NC ...

Page 68

... Basic Switches Standard ORDER GUIDE by ascending electrical capability PIN PLUNGER Catalog Listing Recommended For BZ-2R72-A2 Applications requiring gold alloy contacts BZ/BA TYPE Gold alloy contacts BZ-2R725551-A2 Dustproof and splash resistant seal BZ-2R244-A2 Operating in temp. to 100 hours Lower force BZ-R21-A2 Dim. Dwg. Fig. 1 ...

Page 69

... Amps 2,5-3,61 A 9-13 15 Amps 1,95-2,64 E 7-9 22 Amps 1,95-2,78 F 7-10 1 Amp 2,5-4,17 P 9-15 15 Amps 2,5-4,17 A 9-15 For application help: call 1-800-537-6945. BZ/BA Series P.T. max. O.T. min. D.T. O.P ounces inches inches inches inches 1,11 0,38 1,52 0,01-0,05 21,21 4 .015 .060 ...

Page 70

... BZ-2RQ24-A2 Operating in temperature to 250 F (121 C) Dim. Dwg. Fig. 16 BZ-2RQ172-A2 Applications requiring gold alloy contacts BZ-2RQ1-A2 BZ-2RQ-A2 type applications BZ/BM TYPE with panel mount BZ-2RQ1T04 MIL-S-8805 application (M8805/1-020) requirements BZ-2RQ124-A2 Operating in temperature to 250 F (121 C) ...

Page 71

... ORDER GUIDE Catalog Listing BZ-2RW8072-A2 BZ/BM TYPE BZ-2RW80722555105-A2 BZ-2RW8244-A2 BZ-RW8435-A2 Dim. Dwg. Fig. 21 BZ-2RW876T BZ-2RW80-A2 BZ-2RW84-A2 BA TYPE BZ-2RW805551-A2 BZ-2RWT04 (M8805/1-044) BZ-2RW824-A2 BZ-RW80X Dim. Dwg. Fg. 23 BZ-2RW863-A2 BA-2RV-A2 BM-1RW84-A2 BE-2RV-A4 ADJUSTABLE * Reset characteristics. BZ-2RW899-A2 BZ-2RM-A2 Dim. Dwg. Fg. 22 † From Dim. Dwg. Fig Honeywell Sensing and Control Characteristics: O.F. — ...

Page 72

... Basic Switches Standard SIMULATED ROLLER ORDER GUIDE Catalog Listing BZ-2RW80147-A2 BZ-2RW80196-A2 Dim. Dwg. Fig. 27 ROLLER LEVER BZ-2RW82272-A2 BZ-2RW822725551-A2 BZ/BM TYPE BZ-2RW822-A2 BZ-2RW8222-A2 Dim. Dwg. Fig. 25 BZ-2RW82224-A2 BZ-2RW8225551-A2 BZ-2RW82255-A2-S BA-2RV22-A2 Dim. Dwg. Fig. 28 BM-1RW822-A2 BE-2RV22-A4 BA/BE TYPE BZ-2RW82299-A2 BZ-2RW8299-A2 Dim. Dwg. Fig. 26 For application help: call 1-800-537-6945 ...

Page 73

... Basic Switches Standard ROLLER LEVER ORDER GUIDE Catalog BZ/BM TYPE Listing BZ-2RW82725551-A2 BZ-2RW82-A2 Dim. Dwg. Fig. 29 BZ-2RW825551-A2 BA/BE TYPE BZ-2RW8224-A2 BA-2RV2-A2 BM-1RW82-A2 BE-2RV2-A4 Dim. Dwg. Fig. 30 NOTE: For adjustable operate point and simulated roller lever switches, refer to previous page. BZ-RW922-A2 Dim. Dwg. Fig. 31 ...

Page 74

... Basic Switches Standard FLEXIBLE LEAF ORDER GUIDE Catalog Listing BZ TYPE BZ-2RL-A2 Force and stability of the flexible leaf actuator BZ-2RL5551-A2 Dustproof and splash resistant seal BZ-2RLT04 MIL-S-8805 application Dim. Dwg. Fig. 33 (M8805/1-001) requirements BZ-2RL24-A2 Operating in temperature BA/BE TYPE to BZ-RLX Manual reset. Solder terminals ...

Page 75

... Amps 3,10-5,56 2,78 differential travel Y 11-20 For application help: call 1-800-537-6945. BZ/BA Series provides a single pulse or momentary closure of the contacts with each cycle of operation. Double break versions can interrupt grea- ter inductive loads and feature shorting bar construction. A split contact version allows control of the two isolated circuits. Characteristics: O.F. – ...

Page 76

... U 3.5 As above, with 5 Amps 1,25 0,21 1.9 inch roller lever U 4.5 As above, with 5 Amps 1,95 0,42 1.05 inch roller lever U 7 Honeywell Sensing and Control BZ/BA Series D.T. O inches inches inches inches 0,76 0,13 0,051-0,13 15,9 4 .030 .005 ...

Page 77

... MOUNTING DIMENSIONS (For reference only) PIN PLUNGERS BZ/BM Fig. 1 Fig. 4 PIN PLUNGERS — SPECIAL CIRCUITRY Fig. 5 Fig. 8 Mounting holes accept pins or screws of .139 (3,53 mm) diameter. 58 Honeywell Sensing and Control Fig. 2 Fig. 4-A Fig. 6 Fig. 9 For application help: call 1-800-537-6945. BZ/BA Series BA/BE Fig. 3 Fig. 7 Fig. 10 ...

Page 78

... Basic Switches Standard MOUNTING DIMENSIONS (For reference only) OVERTRAVEL PLUNGERS Fig. 11 Fig. 13 Fig. 15 *Fig Threaded bushings are 15/32-32ns. For application help: call 1-800-537-6945. Fig. 12 Fig. 14 Fig. 16 *Fig. 19 Honeywell Sensing and Control BZ/BA Series *Fig. 17 *Fig ...

Page 79

... Basic Switches Standard MOUNTING DIMENSIONS (For reference only) STRAIGHT LEVERS Fig. 21 Fig Honeywell Sensing and Control Fig. 22 Fig. 25 FLEXIBLE LEAF ACTUATOR Fig. 33 For application help: call 1-800-537-6945. BZ/BA Series Fig. 23 Fig. 26 Fig. 34 ...

Page 80

... Basic Switches Standard MOUNTING DIMENSIONS ROLLER LEVERS Fig. 27 Fig. 30 FLEXIBLE ROLLER LEAF Fig. 35 For application help: call 1-800-537-6945. Fig. 28 Fig. 31 Mounting holes accept pins or screws of .139 (3,53 mm) diameter. Fig. 36 Honeywell Sensing and Control BZ/BA Series Fig. 29 Fig ...

Page 81

... Basic Switches Auxiliary Actuators Standard Basic ORDER GUIDE Roller lever for ‘‘S’’ plunger type BZ and DT switches only. Permits cam operation. Fig. 1 Adjustable roller lever. Tang on top of actuator can be bent to adjust O.P . and F.P . Fig. 2 Straight plunger. Panel mount. ...

Page 82

... BM .125 1.406 1.484 approx. BA 3,18 36,12 37,69 BE .125 1.422 1.484 DT 3,18 35,7 37,69 MT .125 1.406 1.484 BZ 20,62 69,1 70,64 BM .812 2.719 2.781 BA 19,84 69,44 71,42 BE .781 2.734 2.812 DT 18,26 69,1 71,42 MT .719 2.719 2.812 Except where stated* 1,14 mm ...

Page 83

... PLASTIC TERMINAL ENCLOSURES 5PA1 5PA2 Dimensions shown are for reference only. Switches are not included with enclosures. 64 Honeywell Sensing and Control 3PA2* ORDER GUIDE Catalog Listing 3PA1 Side mount enclosure–Can be mounted from either side through .140 (3,55mm) dia. holes on 1 (25,4mm) centers. ...

Page 84

... Catalog Listing 8MA1 Adjustable mounting bracket, adjustment slot on the left. 8MA2 Adjustable mounting bracket, adjustment slot on the right. ‘A’ Dimension for BZ Type 3,6/.14 BA Type 7,8/.31 FEATURES Converts standard basic switches from side to top mount Corrosion resistant Snaps into switch mounting holes— ...

Page 85

... DT-2R-A7 MS25008-1 Dim. Dwg. Fig. 1 DT-2RS1-A7 Dim. Dwg. Fig. 9 DT-2RV3-A7 Dim. Dwg. Fig. 3 DT-2RV-A7 Dim. Dwg. Fig Honeywell Sensing and Control FEATURES Two independent single-pole double- throw circuits on one housing Design permitting several wiring combinations Savings in space and weight Mounting interchangeability with type ...

Page 86

... Reversed lever position J 9-15 Roller lever 10 Amps 1,53-2,64 Reversed lever position J 5.5-9.5 1.90 inch (48,3 mm) roller 10 Amps 1,25-2,09 lever (steel roller) J 4.5-7.5 Honeywell Sensing and Control DT Series P.T. max. O.T. min. D.T. max. O.P inches inches inches inches 1,11 1,02 ...

Page 87

... Basic Switches Double-pole Double-throw MOUNTING DIMENSIONS (For reference only) PIN PLUNGER Fig. 1 STRAIGHT LEVER Fig Honeywell Sensing and Control STRAIGHT LEVER Fig. 2 ROLLER LEVER Fig. 4 For application help: call 1-800-537-6945. DT Series ...

Page 88

... Basic Switches Double-pole Double-throw MOUNTING DIMENSIONS (For reference only) ROLLER LEVER Fig. 5 ROLLER LEVER Fig. 7 STRAIGHT PLUNGER Fig. 9 For application help: call 1-800-537-6945. DT Series ROLLER LEVER Fig. 6 ROLLER LEVER Fig. 8 Honeywell Sensing and Control 69 ...

Page 89

... ORDER GUIDE Catalog Listing MT-4R-A28 Pin plunger SPDT Dim. Dwg. Fig Honeywell Sensing and Control FEATURES Arc resistant case Mechanical life of 100,000 operations — 95% survival Temperature tolerance to 180 F (82 C) Mounting interchangeability with Z switches UL recognized ...

Page 90

... Amps 0,76 0,07 K 2.75 0.25 10 Amps 1,25 0, Amps 3,34 0, Amps 3,34 0, Honeywell Sensing and Control MT Series P.T. max. O.T. min. D.T. max. O.P inches inches inches inches 12,7 1,19 2,16 19,1 0.5 .047 .085 .750 8,89 0,79 1,65 30,2 0 ...

Page 91

... Magnetic Blow-out MOUNTING DIMENSIONS (For reference only) PIN PLUNGER Fig. 1 ROLLER LEVER Fig. 3 FLEXIBLE ROLLER LEAF Fig. 5 Mounting holes accept pins or screws of .139 (3,53 mm) diameter. 72 Honeywell Sensing and Control STRAIGHT LEVER Fig. 2 FLEXIBLE LEAF Fig. 4 For application help: call 1-800-537-6945. MT Series ...

Page 92

... Lower force 15 Amps 1,95-3,1 1,11 V 7-11 4 Honeywell Sensing and Control 3MN Series GENERAL INFORMATION 3MN switches are for use with limit or con- trol mechanisms on machine tools, presses or other industrial equipment. These switches provide easy gang mounting. The terminals of double-break switches must be wired to identical voltage sourc- es and the same polarity ...

Page 93

... Short lever. Adjustment over switch D. 6AS25 Centered lever. Adjustment over Dim. Dwg. Fig. 1 switch D. 74 Honeywell Sensing and Control FEATURES Variety of actuators Choice of circuitries and electrical ratings Choice of terminations Field adjustable operating point on one or both basic switches Characteristics: O.F. – Operating Force; R.F. – Release Force; P .T. – Pre- travel ...

Page 94

... Amps 1.073 T M — — 30,56 25 Amps 3,89 1,11 1.203 38,35 15 Amps 1. — — ROLLER LEVER Fig. 2 Honeywell Sensing and Control 6 AS Series O.T. D.T. min. max. O.P inches inches inches 0,51 2,77 29,77 .020 .109 1.172 0,51 2,77 29,77 .020 ...

Related keywords