E54-CT1 Omron, E54-CT1 Datasheet

TRANSFORMER CURRNT 50A E5AK/E5CK

E54-CT1

Manufacturer Part Number
E54-CT1
Description
TRANSFORMER CURRNT 50A E5AK/E5CK
Manufacturer
Omron
Datasheets

Specifications of E54-CT1

Accessory Type
Current Transformer
Input Current
50A
Transformer Mounting
Chassis
Length/height, External
25mm
Output Current
50A
Transformer Type
Current
Current Rating
50A
Mounting Type
Chassis
Supply Voltage
1000 VoltsAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
E5AK/E5CK
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E54CT1
Z2416
1
Advanced Ramp/Soak Process
Controllers Ideal for Worldwide Use
D
D
D
D
D
D
D
D
D
Ordering Information
When ordering, order control output boards and option boards separately. Example: for a relay control output, order the E53-R output
board in addition to the standard Process Controller (E5AK-T/E5EK-T). Also specify the current transformer.
J Process Controllers
Note: 1. When using the heater burnout alarm function with a standard model, the linear output board cannot be used for the control
Standard model with terminal cover
Position-proportional model with terminal cover
(S
(See Note 3)
Standard model with terminal cover
Position-proportional model with terminal cover
(See Note 3)
(See Note 3)
E5AK-T offers up to eight patterns of simple
programming control (4 patterns for E5EK-T), with 16
steps per pattern.
Temperature and analog inputs in a modular structure,
one-stock type.
High-accuracy: 100 ms sampling (for analog input).
Conforms to international EMC and safety standards.
IP66/NEMA 4 (indoor use) front face.
Serial communications (RS-232C, RS-422 and RS-485)
and transfer output (4 to 20 mA).
Position-proportional control models available for valve
control applications.
Heat/Cool control.
3-year warranty.
E5AK- -T/E5EK- -T
Ramp/Soak Process Controller
2. The Process Controller provides transfer outputs at 4 to 20 mA for the PV and SP values and control outputs at 4 to 20 mA for
3. Position-proportional models are intended for motorized valves (not 4 to 20 mA modulating valves). These use two relays
4. Part numbers ending in --500 available at Omron USA, non -500 numbers available in Omron Canada only. Models with -500
N t 3)
Ramp/Soak Process Controller
p p
outputs (heat).
the current outputs.
(“open” and “close”) which will turn a motor clockwise or counter-clockwise, thus opening or closing a valve.
have a terminal cover for finger protection.
Description
E5AK- -T/E5EK- -T
1/4 DIN
(96
(96 x 96 mm)
1/4 DIN
(96
(96 x 96 mm)
1/8 DIN
(48
(48 x 96 mm)
1/8 DIN
(48 x 96 mm)
(48 x 96 mm)
/
/
/
DIN size
96
96
96
)
)
)
100-240 VAC
100-240 VAC
100-240 VAC
100-240 VAC
Supply voltage
E5AK-TAA2-500 AC100-240
E5AK-TAA2 AC100-240
E5AK-TPRR2-500 AC100-240
E5AK-TPRR2 AC100-240
E5EK-TAA2-500 AC100-240
E5EK-TAA2 AC100-240
E5EK-TPRR2-500 AC100-240
E5EK-TPRR2 AC100-240
Model

E54-CT1 Summary of contents

Page 1

... Position-proportional models are intended for motorized valves (not modulating valves). These use two relays (“open” and “close”) which will turn a motor clockwise or counter-clockwise, thus opening or closing a valve. 4. Part numbers ending in --500 available at Omron USA, non -500 numbers available in Omron Canada only. Models with -500 have a terminal cover for finger protection. ...

Page 2

... E5AK/E5EK 3/1 E5AK/E5EK 3/1 E5AK/E5EK 3/1 Compatible Max. quantity controller E5AK/E5EK 1 E5AK/E5EK 1 E5AK 1 E5EK 1 All 1 E5AK- -T/E5EK- -T Model E53-R E53-S E53-Q E53-Q3 E53-Q4 E53-C3 E53-C3D E53-V34 E53-V35 E53-AK01 E53-AK02 E53-AK03 E53-AKB E53-AKF Model E54-CT1 E54-CT3 E53-COV0809 E53-COV08 Thermo tools (See Note) ...

Page 3

... OFF: leakage current: 0.1 mA max mA, permissible load impedance: 600 Ω max., resolution: approx. 2,600 steps Connect only Omron Current Transformers (E54-CT1 or E54-CT3) Manual output, heating/cooling control, SP limiter, loop burnout alarm, MV limiter, MV change rate limiter, input digital filter, input shift, run/reset, protect functions, scaling function UL 1092, CSA22 ...

Page 4

J Characteristics Indication Thermocouple accuracy Platinum (See Note 1) resistance thermometer Analog input Hysteresis Proportional band (P) Integral (reset) time (I) Derivative (rate) time (D) Control period Manual reset value Alarm setting range Set time Program capacity Programming method Time ...

Page 5

... S RS-422 Baud rate: 1.2/2.4/4.8/9.6/19.2 kbps Baud rate: 1 2/2 4/4 8/9 6/19 2 kbps RS-485 mA: Permissible load impedance: 600 Ω max.; Resolution: approx. 2,600 steps E54-CT1 50 amps 1,000 VAC for 1 min 2 50 Hz, 98 m/s (10G) Approx. 11.5 g ---- Single-phase 0.1 to 49.9 A (in units of 0.1 A) (See Note 1) ...

Page 6

J Temperature Ranges Platinum Resistance Thermometer Input (switch selectable) Range g Setting °C/°F for main setting and alarm Thermocouple Input (switch selectable) Range --200 0.0 to --100 °C to 500.0 to 1,300 850 --300 0.0 to --100 ...

Page 7

Nomenclature J E5AK-T Pattern Number Indicates the pattern number. Program Status Indicators The top indicator indicates the rising step, the middle indicator indicates the constant step, and the bottom indicator indicates the falling step. Bar Graph Indicates the rate of ...

Page 8

... Maintain the specified vertical and horizontal mounting space between each Unit. Units must J E5EK-T 48 (1.89) Note: 1. Recommended panel thickness mm. 2. Maintain the specified vertical and horizontal mounting space between each Unit. Units must not be closely mounted vertically or horizontally. J Accessories (Order Separately) Terminal Cover E53-COV0809 43.2 (1.70) 3 (0.12) 1 ...

Page 9

... Current Transformers E54-CT1 25 (0.98) 10 (0.39) Unit: mm (inch) E54-CT3 40 (1.57 (1.57) 15 (0.59) 21 (0.83) 2.8 (0.11)dia. 5.8 (0.23) 15 dia. 7.5 (0.30) 10.5 (0.41) 40 (1.57) 30 (1.18) 2.36 (0.09) dia. 30 (1.18) 12 dia. 9 (0.35) Two, M3 (depth (1.18) Ramp/Soak Process Controller E5AK- -T/E5EK ...

Page 10

J Setting Up the Output Board 1. Two rectangular holes are provided on the power board (right side of Controller). Fit the two protrusions of the output board into these two holes. 1. With the output board fitted into the ...

Page 11

E53-COV0809, E53-COV08 Terminal Cover Terminal covers are supplied for controllers with -500 in the part number; for non -500 models, order covers separately. Fasten the terminals covers as follows by using the snap pins. Note: Snap pins are provided with ...

Page 12

J Wiring Terminals Terminal Arrangement E5AK-T AC100--240V 50/60 Hz SOURCE TRSF: Transfer output EV1 to 4: Event input PTMR: Potentiometer J Wiring Precautions Use ducts to separate input leads and power lines in order to protect the Controller and its ...

Page 13

J E5AK-T Wiring In the following wiring diagrams, the left side of the terminal numbers indicate the inside of the Controller. Power Supply Input 100 to 240 VAC to terminal numbers 9 and 10 according to the specifications. Sensor Input ...

Page 14

Specifications for Each Output Board Model Output type E53-R Relay E53-S SSR E53-Q Voltage (NPN) E53-Q3 Voltage (NPN) E53-Q4 Voltage (PNP) E53- E53-C3D E53-V34 E53-V35 ...

Page 15

Remote SP Input Connect the input (RSP used as the remote SP to terminal numbers 21 and 22. Only inputs can be connected. Connect the input as follows ...

Page 16

Transfer Output Connect transfer output (TRSF) to terminal numbers 29 and 30. The internal equalizing circuit for transfer output is as follows 20mA Transfer output specifications are as follows ...

Page 17

Control Output Terminal numbers 7 and 8 are for control output 1 (OUT1), and terminal numbers 5 and 6 are for control output 2 (OUT2). The following diagrams show the available output boards and their internal equalizing circuits. With E53-Vjj ...

Page 18

CT Input/Potentiometer When using the HBA function on the E5EK-TAA2 Controller, connect CT input (CT) to terminal numbers 15 to 17. When monitoring the valve opening on the E5EK-TPRR2 Controller, connect the potentiometer (PTMR) to terminal numbers 15 to 17. ...

Page 19

Transfer Output Connect transfer output (TRSF) to terminal numbers 21 and 22. The internal equalizing circuit for transfer output is at right. Transfer output specifications are as follows mA, Permissible load impedance: 600 ...

Page 20

J SSR Connection Example of Process Controller and SSR Digital Controller + Voltage output terminal (for driving SSR) -- Connectable E5jK-T Process Controller with Voltage Output (12 VDC max.) E5CK-T Process Controller with Voltage Output (12 VDC, 20 ...

Page 21

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 22

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...