H7BR-CWV-AC100-240 Omron, H7BR-CWV-AC100-240 Datasheet - Page 21

COUNTER DIGITAL LCD 100-240V NPN

H7BR-CWV-AC100-240

Manufacturer Part Number
H7BR-CWV-AC100-240
Description
COUNTER DIGITAL LCD 100-240V NPN
Manufacturer
Omron
Series
H7BRr
Type
Digital Counterr

Specifications of H7BR-CWV-AC100-240

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
100 V ~ 240 VAC
Display Type
*
Equipment Type
Digital Counter
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7BRCWVAC100240
H7BR
Note: Do not connect unused terminals.
The inputs of the H7BR are no-voltage (short-circuit or open) inputs and voltage inputs.
(Key protection only for no-voltage inputs)
No-voltage Inputs
H7BR-B (standard type)
2 Stages, Contact and PNP
Transistor Outputs
H7BR-BWP
H7BR-BWVP
Open Collector
No-voltage Input Signal Levels
Batch count reset
Connections
Key protection input
No-contact
input
Contact
input
*H: Transistor ON
Sensor
1. High level
Transistor ON
Residual voltage: 2 V max.
Impedance when ON: 1 kΩ max.
2. Low level
Transistor OFF
Impedance when OFF: 100 kΩ max.
Use contacts which can adequate-
ly switch 2 mA at 5 V
15
16
Reset input
(–)
0 V
(-)
8
1
Sensor
power supply
9 10 11
2
(+)
OUT 2
3
CP2 input
100 to 240 VAC/24 VAC
12 to 24 VDC
CP1 input
4
12
OUT 1
5
Gate input
*H: Relay ON
13
(+)
12/24 VDC
6
14
Voltage Output
Output common
7
OUT 1
OUT 2
Batch
Sensor
17
18
H7BR-C (
2 Stages, Contact and PNP
Transistor Outputs
H7BR-CWP
H7BR-CWVP
Compensation input
Key protection input
*H: Transistor ON
±
range type)
Contact Input
15
16
Reset input
(–)
0 V
8
(-)
1
Sensor
power supply
9 10 11
2
(+)
OUT 2
3
CP2 input
100 to 240 VAC/24 VAC
12 to 24 VDC
CP1 input
4
12
OUT 1
5
Gate input
13
(+)
12/24 VDC
6
Unused
14
Output common
7
OUT 1
OUT 2
17
18
H7BR
21