H7BR-CWV-AC100-240 Omron, H7BR-CWV-AC100-240 Datasheet - Page 24

COUNTER DIGITAL LCD 100-240V NPN

H7BR-CWV-AC100-240

Manufacturer Part Number
H7BR-CWV-AC100-240
Description
COUNTER DIGITAL LCD 100-240V NPN
Manufacturer
Omron
Series
H7BRr
Type
Digital Counterr

Specifications of H7BR-CWV-AC100-240

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
100 V ~ 240 VAC
Display Type
*
Equipment Type
Digital Counter
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7BRCWVAC100240
Cat. No. M009-E1-01D
OMRON Corporation
Industrial Automation Company
Industrial Control Components Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7119/Fax: (81)75-344-7149
H7BR
Actual measurements in N and K modes.
*The variation in delays is due to different modes and conditions.
For systems where the delay is a problem, take actual measure-
ments under operating conditions.
24
Contact output 1, 2
Transistor output 1, 2
Batch outputs
Output Delay
The following table shows the delay from when the present value
passes the set value until the output is produced. (The delay is
the result of output control time, signal transmission time, relay
switching time, etc.)
Control output
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
30 Hz {cps}
1 kHz {cps}
5 kHz {cps}
10 kHz {cps}
30 Hz {cps}
1 kHz {cps}
5 kHz {cps}
10 kHz {cps}
30 Hz {cps}
1 kHz {cps}
5 kHz {cps}
10 kHz {cps}
Max. counting
In the interest of product improvement, specifications are subject to change without notice.
speed
18 to 24 ms
4.7 to 5.8 ms
4.4 to 5.4 ms
4.3 to 5.3 ms
13.5 to 20 ms
0.59 to 0.81 ms
0.29 to 0.44 ms
0.24 to 0.36 ms
13.6 to 20.2 ms
0.72 to 0.94 ms
0.42 to 0.57 ms
0.37 to 0.49 ms
Output delay*
(Transistor Output)
Response Delay Time for Resetting
Other
Max. Count Speed of Batch Counter
The maximum count speed of the batch counter is 1 kHz {cps}.
The batch counter counts the number of count-up times at the
last stage (i.e., the number of preset-value counts if the H7BR is
a one-stage model and the number of SET2 preset-value counts
if the H7BR is a two-stage model). An interval of 1 ms or more is
required before the batch counter counts up again after it has
counted up.
Take the following output delays into consideration after the
reset signal input is turned ON and the output is turned OFF.
When the Counter is installed in a control box and tests are
conducted which may damage the Counter’s internal circuitry
(for example, a test measuring the maximum voltage difference
between the control circuit and metal components), remove the
Counter from the control box or short-circuit the terminals.
1 ms
20 ms
Minimum reset
signal width
0.8 to 1.2 ms
15 to 25 ms
Output delay
time
Printed in Japan
0103-0.5C (1190)
H7BR