MK2049-34SAILF IDT, Integrated Device Technology Inc, MK2049-34SAILF Datasheet - Page 6

no-image

MK2049-34SAILF

Manufacturer Part Number
MK2049-34SAILF
Description
IC VCXO PLL CLK SYNTH 20-SOIC
Manufacturer
IDT, Integrated Device Technology Inc
Type
PLL Clock Synthesizerr
Datasheet

Specifications of MK2049-34SAILF

Pll
Yes
Input
Clock
Output
Clock
Number Of Circuits
1
Ratio - Input:output
1:3
Differential - Input:output
No/No
Frequency - Max
77.76MHz
Divider/multiplier
Yes/Yes
Voltage - Supply
3.15 V ~ 3.45 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SOIC
Frequency-max
44.736MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK2049-34SAILF
Manufacturer:
IDT
Quantity:
74
Part Number:
MK2049-34SAILFTR
Manufacturer:
IDT
Quantity:
20 000
External Component Selection
The MK2049-34A requires a minimum number of external components for proper operation. Decoupling capacitors of
0.01 F must be connected between VDD and GND pins close to the chip (especially pins 4 and 7, 15 and 17), and 33
series terminating resistors should be used on clock outputs with traces longer than one inch (assuming 50 traces). The
selection of additional external components is described in the following sections.
Loop Filter
Information on how to configure the external loop filter, connected between pins CAP1 and CAP2, can be found on the IDT
web site.
Crystal Operation
The MK2049-34A operates by phase locking the input signal to a VCXO which consists of the recommended pullable VCXO
crystals and the integrated VCXO oscillator circuit on the MK2049-34A. To achieve the best performance and reliability, the
layout guidelines shown on the previous page should be closely followed.
The frequency of oscillation of a quartz crystal is determined by its cut and by the load capacitors connected to it. The
MK2049-34A has variable load capacitors on-chip which “pull” or change the frequency of the crystal. External stray
capacitance must be kept to a minimum to ensure maximum pullability of the crystal. To achieve this, the layout should use
short traces between the MK2049-34A and the crystal.
For the VCXO to operate correctly, a pullable crystal must be used. For more information, including a list of approved
crystals, please refer to application note MAN05.
Absolute Maximum Ratings
Recommended Operation Conditions
IDT™ / 3.3 VOLT COMMUNICATIONS CLOCK VCXO PLL
MK2049-34A
3.3 VOLT COMMUNICATIONS CLOCK VCXO PLL
Stresses above the ratings listed below can cause permanent damage to the MK2049-34A. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at
these or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature
Storage Temperature
Junction Temperature
Soldering Temperature
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Item
6
+3.15
Min.
-40
7 V
-0.5 V to VDD+0.5 V
-40 to +85 C
-65 to +150 C
175 C
260 C (10 to 20 seconds max.)
Typ.
+3.3
Rating
+3.45
Max.
+85
VCXO AND SYNTHESIZER
MK2049-34A REV E 051310
Units
V
C

Related parts for MK2049-34SAILF