1618387-7 TE Connectivity, 1618387-7 Datasheet

LEV200A4NAA=RELAY, SPST-NO

1618387-7

Manufacturer Part Number
1618387-7
Description
LEV200A4NAA=RELAY, SPST-NO
Manufacturer
TE Connectivity
Type
Contactor Relayr
Datasheet

Specifications of 1618387-7

Relay Construction
Contactor
Contact Arrangement
SPST-NO
Coil Voltage Dc
12V
Contact Form
1 Form A
Contact Current Rating
500A
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Lead Free Status / Rohs Status
Compliant
Product Facts
I Designed to be the lowest cost
I Available with bottom or side
I Optional auxiliary contact for
I Hermetically sealed –
I Typical applications include
I Versatile coil/power
I Designed and built in
Performance Data
Parameter
Contact Arrangement, power contacts
Rated Operating Voltage
Continuous (Carry) Current, Typical
Make/Break Current at Various Voltages
Break Current at 320Vdc
Contact Resistance, Typ. (@200A)
Load Life
Mechanical Life
Contact Arrangement, auxiliary contacts
Aux. Contact Current, Max.
Aux. Contact Current, Min.
Aux. Contact Resistance, Max.
Operate Time @ 25°C
Dielectric Withstanding Voltage
Insulation Resistance @ 500Vdc
Shock, 11ms 1/2 sine, peak, operating
Vibration, sine, 80-2000Hz., peak
Operating Ambient Temperature
Weight, Typical
1/
2/
3/
4/
© 2007 by Tyco Electronics Corporation. All Rights Reserved.
KILOVAC, TE Logo and Tyco Electronics are trademarks.
Other products and company names mentioned herein may be trademarks of their
respective owners.
Catalog 9-1773439-1
Revised 6-08
www.tycoelectronics.com
Close (includes bounce), Typ.
Bounce (after close only), Max.
Release (includes arcing), Max @ 2000A ms
Consult Factory for required conductors for higher (500+ A) currents
Main power contacts
50 at end of life
Does not meet dielectric & IR after test, 1700 amp for unit with Aux. Contacts
Contacts will operate with 0.8V nom < V coil < 1.1V nom over temperture range.
sealed contactor in the industry
with its current rating (500+A
carry, 2000A interrupt at
320Vdc).
mounting -- not position
senstive.
easy monitoring of power
contact position.
intrinsically safe, operates in
explosive/harsh environments
with no oxidation or
contamination of coils or
contacts, including long periods
of non-operation.
battery switching and backup,
DC voltage power control, circuit
protection and safety.
connections.
accordance to AIAG QS9000.
1
/
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
megohms 100
1
mohms 0.2
Units
Cycles See next page
Cycles 100,000
lb.(kg)
/
ohms
Vrms
Vdc
mA
ms
ms
°C
A
A
A
A
G
G
KILOVAC LEV200 Series Contactor With 1 Form X
Contacts Rated 500+ Amps, 12-900Vdc
For factory-direct application assistance, contact Earle Alldredge, product manager.
Dial 800-253-4560, ext. 2055, or 805-220-2055. Email earle.alldredge@tycoelectronics.com
Value for LEV200 Series
1 Form X (SPST-NO-DM)
12 - 900
500 @ 65°C, 400 mcm conductors
See next page
2,000, 1 cycle
1 Form A (SPST-NO)
2A @ 30Vdc / 3A @ 125Vac
100mA @ 8V
0.417@ 30Vdc / .150 @ 125Vaac
25
7
12
2,200 @ sea level (leakage <1mA)
20
20
-40 to +85
1.3 (.60)
2
/
3
/
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Coil Data (valid over temperature range)
Nominal Voltage
Pickup Voltage (will operate)
Voltage (Max.)
Dropout Voltage
Coil Resistance @ 25° (Typ.)
Part Numbering System
Typical Part Number
Series:
LEV200 = 500+ Amp, 12-900Vdc Contactor
Contact Form:
A = Normally Open
H = Normally Open with Aux. Contacts. (Option “H” requires
Note: Other auxiliary contact forms available. Consult factory.
Coil Voltage:
4 = 12Vdc
8 = 96Vdc
Notes: Consult factory for detailed specifications and availability of
Coil Wire Length:
A = 15.3 in (390 mm)
Coil Terminal Connector:
N = None, stripped wires (Requires option “A” in previous step.)
A = Studs, #10-32 Threaded (Electrical connection is made to the tab
Note: Specify option A, stripped wires, for coil voltages > 96Vdc
Mounting & Power Terminals:
A = Bottom Mount & Male 10mm x M8 Threaded Terminals
F = Side Mount & Male 10mm x M8 Threaded Terminals
Consult factory regarding other available mountings and power terminals.
NOTE: All part numbers are RoHS compliant (and always have been).
option “A” in Coil Wire Length and option “N” in Coil
Terminal Connector.)
at the base of the stud.)
coils not listed in “Coil Data” table above.
In coil voltage codes, 115Vac is designated by the letter “O”
rather than the numeral “0.”
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
L = 110Vdc
5 = 24Vdc
N = None (Requires option “A” in next step.)
0.75 - 2.0Vdc
O = 115Vac
6 = 48Vdc
11 ohms
9.0Vdc
12Vdc
15Vdc
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
LEV200 A
4/
1.0 - 5.0Vdc
40 ohms
9 = 240Vac
19.0Vdc
K = 72Vdc
24Vdc
30Vdc
4
RoHS
Ready
2.0 - 7.0Vdc
145 ohms
N
38.0Vdc
48Vdc
60Vdc
A
A
1