IC RTC I2C 2-WIRE 8-SOP

S-35390A-J8T1G

Manufacturer Part Number
S-35390A-J8T1G
Description
IC RTC I2C 2-WIRE 8-SOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35390A-J8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
728-1006-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35390A-J8T1G
Manufacturer:
SEK
Quantity:
1 000
Part Number:
S-35390A-J8T1G
Manufacturer:
SEK
Quantity:
1 000
Part Number:
S-35390A-J8T1G
Manufacturer:
SEIKO/精工
Quantity:
20 000
Company:
Part Number:
S-35390A-J8T1G
Quantity:
194
Company:
Part Number:
S-35390A-J8T1G
Quantity:
521
Rev.3.0
Power-on Detection Circuit and Register Status
The power-on detection circuit operates by power-on the S-35390A, as a result each register is cleared; each register is
set as follows.
“1” is set in the POC flag (B0 in the status register 1) to indicate that power has been applied. To correct the oscillation
frequency, the status register 2 goes in the mode the output of user-set frequency, so that 1 Hz clock pulse is output from
the
the output of user-set frequency mode is cleared. (Refer to “ Register Status After Initialization”.)
For the regular operation of power-on detection circuit, as seen in Figure 20, the period to power-up the S-35390A is that
the voltage reaches 1.3 V within 10 ms after setting the IC’s power supply voltage at 0 V. When the power-on detection
circuit is not working normally is; the POC flag (B0 in the status register) is not in “1”, or 1 Hz is not output from the
pin. In this case, power-on the S-35390A once again because the internal data may be in the indefinite status.
Do not transmit data immediately after power-on at least 0.5 sec because the power-on detection circuit is operating.
INT pin. When “1” is set in the POC flag, be sure to initialize. The POC flag is set to “0” due to initialization so that
Real-time data register :
Status register 1 :
Status register 2 :
INT1 register :
INT2 register :
Clock correction register :
Free register :
_00
1
*1. 0 V indicates that there are no potential differences between the VDD
pin and VSS pin of the S-35390A.
Figure 20 How to Raise the Power Supply Voltage
00 (Y), 01 (M), 01 (D), 0 (day of the week), 00 (H), 00 (M), 00 (S)
“01h”
“80h”
“80h”
“00h”
“00h”
“00h”
Seiko Instruments Inc.
Within 10 ms
1.3 V
0 V
*1
2-WIRE REAL-TIME CLOCK
S-35390A
INT
17
1