S-35390A-T8T1G Seiko Instruments, S-35390A-T8T1G Datasheet - Page 28

IC RTC I2C 2-WIRE 8-TSSOP

S-35390A-T8T1G

Manufacturer Part Number
S-35390A-T8T1G
Description
IC RTC I2C 2-WIRE 8-TSSOP
Manufacturer
Seiko Instruments
Type
Clock/Calendarr
Datasheet

Specifications of S-35390A-T8T1G

Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP
Function
Clock/Calendar/Alarm/Battery Backup/Interrupt
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial (2-Wire, I2C)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
728-1007-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
18 700
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
10 000
Part Number:
S-35390A-T8T1G
Manufacturer:
SEIKO
Quantity:
20 000
Company:
Part Number:
S-35390A-T8T1G
Quantity:
290
28
2-WIRE REAL-TIME CLOCK
S-35390A
(1 Hz output)
3. How to confirm setting value for register and result of correction
INT1 pin
The S-35390A does not adjust the frequency of the crystal oscillation by using the clock-correction function. Therefore
users cannot confirm if it is corrected or not by measuring output 32.768 kHz. When the function to clock-correction is
being used, the cycle of 1 Hz clock pulse output from the
Figure 31 .
Measure a and b by using the frequency counter
measurement results.
Calculate the error of the clock based on the average frequency (Tave).
confirmation.
Confirmation example: When B0 =0, 66h is set
*1. Use a frequency counter with 7-digit or greater precision.
Caution
B0 = 0, Tave = (a × 19 + b) ÷ 20
B0 = 1, Tave = (a × 59 + b) ÷ 60
Calculating the average frequency allows to confirm the result of correction.
Measurement results: a = 1.000080 Hz, b = 0.998493 Hz
Before correction
After correction
Measure the oscillation frequency under the usage conditions.
Clock Correction Register Setting Value
B0 = 0, a : 19 times, b : Once
B0 = 1, a : 59 times, b : Once
a
00 h (Tave = a)
66 h (Tave = (a × 19 + b) ÷ 20)
Figure 31 Confirmation of Correction Result
a
19 times or 59 times
Seiko Instruments Inc.
*1
.
INT
Calculate the average frequency (Tave) based on the
Average Frequency [Hz]
1.000080
1.00000065
1
pin changes once in 20 times or 60 times, as shown in
a
The following shows an example for
Once
Per Day [s]
86393
86399.9
b
Rev.3.0
a
_00

Related parts for S-35390A-T8T1G