Specifications of 3-644389-6

Connector TypeConnector AssemblyConnector DesignFeed Through
Product LineMTA-156Termination Method To Wire/cableIDC Standard
Wire Size (mm² [awg])0.3-0.4² [22]Mating Connector LockWith
Four Points Of ContactWithShroudedNo
Mounting EarsWithoutMating Connector Lock TypeLocking Ramp
Panel Mount RetentionWithoutSolder Tail Contact PlatingBright Tin
Number Of Positions6Centerline (mm [in])3.96 [0.156]
NarrowNoPost Number(s) OmittedNone
Cable Exit Angle90°Contact TypeSocket
Contact Plating, Mating Area, MaterialTinContact Base MaterialHigh Conductivity Copper Alloy
Connector StyleReceptacleHousing ColorBlack
Mating AlignmentWithUl Flammability RatingUL 94V-0
Housing MaterialNylonMating Alignment TypePolarizing Tab
Rohs/elv ComplianceRoHS compliant, ELV compliantLead Free Solder ProcessesNot relevant for lead free process
Rohs/elv Compliance HistoryAlways was RoHS compliantApplies ToWire/Cable
Application UseWire-to-Board  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
Page 1/10

Download datasheet (496Kb)Embed
Next
Product
Specification
Connector System, MTA 156 Quad
1.
SCOPE
1.1.
Content
This specification covers performance, tests and quality requirements for the TE Connectivity (TE)
MTA-.156 Quad Contact connector system. This connector system can be mass or single wire
terminated utilizing insulation displacement technology on .156 inch centerlines and mates with .045
inch square posts. This system provides a reliable interconnection between wires and posts mounted
on printed circuit boards. Quad connector is available in 2 through 12 positions. This connector system
is designed to be terminated to 18, 20 and 22 AWG wire, solid, stranded and prefused or overcoated
wire, tin plated, UL style 1007, 1061 or wire which specifies PVC insulation with temperature rating
compatible with specified operating temperatures, see Figure 4A. Wire shall be applied per application
requirements specified in Application Specification 114-1048. Wire insulation diameter shall be .070
inch maximum OD for mass terminated wire and .095 inch maximum OD for single terminated wire.
1.2.
Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be performed using the applicable inspection plan and product drawing.
2.
APPLICABLE DOCUMENTS
The following Tyco Electronics documents form a part of this specification to the extent specified herein.
Unless otherwise specified, the latest edition of the document applies. In the event of conflict between
the requirements of this specification and the product drawing, the product drawing shall take
precedence. In the event of conflict between the requirements of this specification and the referenced
documents, this specification shall take precedence.
!
109-1: General Requirements for Test Specifications
!
109 Series: Test Specifications as indicated in Figure 1
!
114-1048: Application Specification
!
501-247: Test Report
3.
REQUIREMENTS
3.1.
Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable product
drawing.
3.2.
Materials
!
Contact: Copper alloy, bright tin-lead plated, lubricated
!
Headers: Thermoplastic polyester, UL94V-0
!
Header post: Brass, .045 inch square, tin plated
!
Housing: Nylon 6/6, black, UL94V-0
©2011 Tyco Electronics Corporation,
| Indicates change
a TE Connectivity Ltd. Company
*Trademark
All Rights Reserved
TE logo is a trademark.
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1219
11Mar11 Rev C
1 of 10
LOC B

3-644389-6 Summary of contents

  • Page 1

    ... Test Report 3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing. 3.2. Materials ! Contact: Copper alloy, bright tin-lead plated, lubricated ! Headers: Thermoplastic polyester, UL94V-0 ! Header post: Brass, .045 inch square, tin plated ...

  • Page 2

    ... Meets requirements of product drawing and Application Specification 114-1048. ELECTRICAL 3 milliohms maximum initial. ∆R 3 milliohms maximum. 5000 megohms minimum initial. 2.2 kvac dielectric withstanding voltage. 1 minute hold. 30° C maximum temperatur e rise at specified current. See Note. MECHANICAL Wire Size Slot Tensile AWG Lbs Minimum 18 26 ...

  • Page 3

    ... See Figure Spec 109-26-1. Subject mated connectors to 50 G's half-sine shock pulses of 11 milliseconds duration. 3 shocks in each direction applied along 3 mutually perpendicular planes, 18 total shocks. See Figure 5. TE Spec 109-27. Mate and unmate connector assemblies for 25 cycles. ...

  • Page 4

    ... Test Description Humidity-temperature cycling. Temperature life. Shall meet visual requirements, show no physical damage and shall meet requirements of NOTE additional tests as specified in Test Sequence in Figure 3. 3.6. Product Qualification and Requalification Test Sequence Test or Examination Examination of product Termination resistance, dry circuit Insulation resistance ...

  • Page 5

    ... Connector assemblies shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 30 connector assemblies and 10 position sizes. Test groups and 9 shall each consist of 5 connector assemblies (6 position each) per group per wire size. Test group 4 shall consist of minimum of 30 contacts from minimum of 3 connectors for maximum wire size ...

  • Page 6

    ... Termination resistance equals millivolts drop divided by test current less resistance of total NOTE length of wire. 2. After wave soldering, board and posts shall be cleaned to remove all flux and contaminates. Resistance & Temperature Measurement Points Rev C Figure 3 PCB 93-660164 108-1219 ...

  • Page 7

    Single Circuit, I Operating temperature is defined as ambient temperature plus current produced temperature rise NOTE in contact system. Operating temperature in above graph is area under curve. Rev AWG, Continuous Operating RMS DC (95% ...

  • Page 8

    ... From current carrying capability curve (Figure 2A), base current rating at 75° amperes. ! From rating factors table (Figure 2B) for 20 AWG wire, rating factor at 50% loading is 0.79. ! Multiply base rating by rating factor: 10.0 X 0.79 = 7.9 amperes ! Each of 3 equally distributed contacts can carry 7.9 amperes maximum. Rev C Multiplication Factor (F) Wire Size AWG Connector Assembly 22 ...

  • Page 9

    ... Rev C Figure 5 Vibration & Physical Shock PCB 93-660164 108-1219 ...

  • Page 10

    ... Rev C Figure 6 Vibration & Current Cycling PCB 93-660092-1 108-1219 ...