Number Of Bits
12
Sampling Rate (per Second)
3.65M
Data Interface
Parallel
Number Of Converters
1
Power Dissipation (max)
1.82W
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
To start a conversion using internal clock mode, pull
CONVST low for the acquisition time (t
acquires the signal while CONVST is low, and conver-
sion begins on the rising edge of CONVST. The end-of-
conversion signal (EOC) pulses low whenever a
conversion result becomes available for read. The end-
of-last-conversion signal (EOLC) goes low when the last
conversion result is available (Figure 7).
To start a conversion using external clock mode, pull
CONVST low for the acquisition time (t
acquires the signal while CONVST is low. The rising
edge of CONVST is the sampling instant. Apply an
external clock to CLK to start the conversion. To avoid
T/H droop degrading the sampled analog input signals,
8-/4-/2-Channel, 12-Bit, Simultaneous-Sampling ADCs
with ±10V, ±5V, and 0 to +5V Analog Input Ranges
Figure 7. Read During Conversion—Channel 0 and Channel 1 Selected, Internal Clock
22
CONVST
D0–D11
______________________________________________________________________________________
EOLC
EOC
CS*
RD
*CS CAN BE LOW AT ALL TIMES, LOW DURING THE RD CYCLES, OR THE SAME AS RD.
TRACK
t
ACQ
INSTANT
SAMPLE
Starting a Conversion
ACQ
ACQ
t
CONV
). The T/H
). The T/H
t
CTR
t
ACC
t
the first CLK pulse must occur within 10µs from the
rising edge of CONVST. Additionally, the external clock
frequency must be greater than 100kHz to avoid T/H
droop-degrading accuracy. The first conversion result
is available for read when EOC goes low on the rising
edge of the 13th clock cycle. Subsequent conversion
results are available after every third clock cycle there-
after (Figures 8 and 9).
In both internal and external clock modes, hold
CONVST high until the last conversion result is read. If
CONVST goes low in the middle of a conversion, the
current conversion is aborted and a new conversion is
initiated. Furthermore, there must be a period of bus
inactivity (t
edge of CONVST for the specified ADC performance.
REQ
HOLD
t
EOC
CH0
t
QUIET
NEXT
t
RDH
) for 50ns or longer before the falling
t
RDL
CH1
t
t
CVEOLCD
QUIET
t
RTC
≥ 50ns