FCB-205-0228M TE Connectivity, FCB-205-0228M Datasheet

POWER RELAY, DPDT-2CO, 28VDC, 5A PLUG IN

FCB-205-0228M

Manufacturer Part Number
FCB-205-0228M
Description
POWER RELAY, DPDT-2CO, 28VDC, 5A PLUG IN
Manufacturer
TE Connectivity
Datasheet

Specifications of FCB-205-0228M

Relay Type
Military / Aerospace
Coil Voltage Vdc Nom
28V
Contact Current Max
5A
Coil Resistance
500ohm
Contact Configuration
DPDT
Coil Type
DC, Monostable
Relay Mounting
PCB
Rohs Compliant
No
The Series FCB-205 relay is a polarized single-side stable design, where the flux from a permanent
magnet provides the armature holding force in the deactivated state, and its flux path is switched
and combined with the coil flux in the operated state. This results in appreciably increased contact
pressure in both states over that of a spring return nonpolar design. We also manufacture other
forms of the FCB relay:
FCB-405: 5 AMP 4PDT RELAY
FCB-310: 10 AMP 3PDT RELAY
Tyco Electronics Mid-Range Military/Aerospace Relays
HERMETICALLY SEALED
ALL WELDED CONSTRUCTION
BALANCED FORCE
PERMANENT MAGNET DRIVE
CONTACTS RATED LOW LEVEL
TO 5 AMPS 28 VDC AND 115/200 VAC
400 Hz , 3 PHASE.
WEIGHT .54 OUNCES MAX. (15.4 GRAMS)
Low Level Switching Capability: With contacts operating a load of 10 to 50 microamperes at 10 to
50 millivolts, the contact resistance miss detection level shall be 100 ohms max. Cycling rate is
1 to 12 per second, for 100,000 operations.
OVERLOAD CURRENT 20 AMPS DC, 30AMPS 400Hz
RUPTURE CURRENT 25 AMPS DC, 40 AMPS 400Hz
CONTACT MAKE BOUNCE 1.0 MILLISECOND MAX. AT NOMINAL VOLTAGE
MAX. CONTACT DROP AT 5 AMPS: INITIAL 0.100 VOLTS.
END OF LIFE 0.125 VOLTS
Ratings Are Continuous Duty
CONTACT RATING-AMPERES
Resistive
Inductive
Motor
Lamp
TYPE OF
LOAD
SERIES
LIFE (MIN.)
CYCLES X 10
* 60 Hz LOADS RATED FOR 10,000 OPERATIONS
100
100
100
20
5 AMPERES, DPDT
3
34
28 VDC
5
3
2
1
115VAC
400Hz
5
5
3
1
115/200VAC
400 Hz, 30
5
5
3
1

Related parts for FCB-205-0228M

FCB-205-0228M Summary of contents

Page 1

... PHASE. WEIGHT .54 OUNCES MAX. (15.4 GRAMS) The Series FCB-205 relay is a polarized single-side stable design, where the flux from a permanent magnet provides the armature holding force in the deactivated state, and its flux path is switched and combined with the coil flux in the operated state. This results in appreciably increased contact pressure in both states over that of a spring return nonpolar design ...

Page 2

... Tyco Electronics Mid-Range Military/Aerospace Relays COIL DATA NOMINAL COIL VOLTAGES CODE ( CODE 4 COILS HAVE BACK EMF SUPPRESSION TO 42 VOLTS MAX COIL RESISTANCE 10% AT 25˚C; C. RELAY WILL STAY IN PICKUP STATE DOWN TO MUST HOLD VOLTAGES SHOWN. GENERAL SPECIFICATIONS TEMPERATURE RATING: ALTITUDE: SHOCK:* VIBRATION, SINUSOIDAL:* ...

Page 3

... SERIES Tyco Electronics Mid-Range Military/Aerospace Relays Below are shown the standard terminal types and the enclosures available. Specify the assembly as indicated under How To Order. Dimensions are shown in inches TERMINALS Socket Pin Terminals CODE Socket Pins Gold Plated. Polarizing "A" pin tin/lead plated ...

Page 4

... ENCLOSURE (With Flanges) COIL (28 VDC With Transient Suppression). NOTE: Only DC coil models are QPL Approved 5 AMPERES, DPDT TRANSIENT SUPPRESSION TERMINAL LAYOUT .150 Typ (3.81) 37 SERIES POLARIZING PIN - BLUE BEAD .075 (1.90) Polarizing Pin - +X1 Blue Bead .075 (1.90) .150 Typ (3.81) FCB-205 ...

Related keywords