T92S11D22-24

Manufacturer Part NumberT92S11D22-24
DescriptionPOWER RELAY, DPDT, 24VDC, 30A, PANEL
ManufacturerTE Connectivity
SeriesT92
T92S11D22-24 datasheet
 

Specifications of T92S11D22-24

Relay TypeGeneral PurposeCoil Voltage Vdc Nom24V
Contact Current Max40AContact Voltage Ac Nom600V
Contact Voltage Dc Nom28VCoil Resistance350ohm
Contact ConfigurationDPDTRohs CompliantYes
Brand/seriesT92 SeriesContact FormDPDT
Current, Rating30 ADimensions2.060 in. L x 1.359 in. W x 1.209 in. H (Approx.)
FunctionPowerMaterial, ContactSilver Cadmium Oxide
Mounting TypePanelNumber Of Pins8
StandardsUL, CSA, RoHS, VDETerminationQuick Connect
Tyco Part Number9-1393211-4Voltage, Control24 VDC
Voltage, Rating600 VACCoil Voltage24 V
Contact Rating30 A at 24 VDCContact TerminationQuick Connect
Mounting StyleFlangePower Consumption1.7 W
Contact MaterialSilver Cadmium OxideCoil Current30 A
Coil TypeMonostableLead Free Status / Rohs StatusRoHS Compliant part
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (498Kb)Embed
Next
Features
• 30A DPST-NO and DPDT switching capabilities.
• Designed to control compressor loads to 3.5 tons, 25.3 FLA, 110 LRA.
• Extended life – >300,000 operations at 30A, 240VAC (DC coil).
>100,000 operations at 30A, 240VAC (AC coil).
• Meets requirements of UL873 and UL508 spacings.
– .315” (8mm) through air, .375” (9.5mm) over surface.
• Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-contacts.
• Meets requirements of UL Class F construction.
• UL approved for 600VAC switching (1.5HP).
• Conforms to VDE 0435, 0631, and 0700.
• New screw terminal version.
Contact Ratings @ 25°C with relay properly vented.
Remove tape over vent hole after soldering and cleaning.
Arrangements: 2 Form A (DPST-NO) and 2 Form C (DPDT).
Materials: Silver cadmium oxide and silver tin indium oxide.
Max. Load Rating, Silver Cadmium Oxide Contacts:
Normally Open Contacts:
40A @ 277VAC, resistive; 6K Ops. (Flange Mount);
30A @ 120/277VAC, resistive;
10A @ 600VAC, resistive;
1 HP @ 120VAC, 3 HP @ 240VAC;1.5 HP @ 480VAC, 1.5 HP @ 600VAC
110 LRA, 25.3 FLA, @ 240VAC with DC coil
;
(1)
60 LRA, 14 FLA @ 240VAC with AC coil;
3A @ 240VAC pilot duty;
20A @ 28VDC;
TV10 @ 120VAC.
VDE Rating (Flange Mount): 20A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
VDE Rating (PC Mount): 30A @ 400VAC, 100K Ops. (30K Ops. for
Form C Models).
Normally Closed Contacts:
3A @ 28VDC or 277VAC, 2A @ 480VAC, 1A @ 600VAC.
VDE Rating (Flange or PC Mount): 3A @ 400VAC, 30K Ops.
Max. Load Rating, Silver Tin Indium Oxide Contacts
Normally Open Contacts Only:
30A @ 120/277VAC, resistive; 200K Ops., DC Coil; 100K Ops, AC Coil
20A @ 480VAC, resistive;
1.5 HP @ 120VAC, 2 poles making/breaking (see Fig. 1)
3 HP @ 240VAC, 3 phase, DC coil only;
3 HP @ 480VAC, 3 phase, DC coil only;
2 HP @ 600VAC, 3 phase, DC coil only.
Min. Load Rating:
Normally Open Contacts: 500mA @ 12VAC/VDC.
Normally Closed Contacts: 100mA @ 6VAC/VDC.
Expected Mechanical Life: 5 million operations.
Expected Electrical Life: 100,000 operations at rated load, except as
specifically noted otherwise.
Catalog 1308242
Issued 3-03 (PDF Rev. 8-07)
T92
series
Two-Pole, 30 Amp
PC Board or Panel Mount Relay
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files
of the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Contact Ratings (continued)
ARI 780-86 Endurance Test (section 6.6):
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Single Phase/Two Pole (Both poles together switching a single load)
110 LRA, 25.3 FLA, 200K operations (DC Coil)
L1
L2
Figure 1
T1
Single Phase Per Pole (Single load per pole)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
L1
T1
Figure 2
Notes: Vent hole tape must be removed to achieve all listed ratings.
Initial Dielectric Strength
Between Contacts and Coil: 4,000V rms, 50/60 Hz.
Between Open Contacts: 1,500V rms, 50/60 Hz.
Between Poles: 2,000V rms, 50/60 Hz.
Initial Insulation Resistance
Between Mutually Insulated Elements: 10
Coil Data
Voltage: 12 through 110VDC and 12 through 277VAC.
Resistance: See Coil Data table.
Nom. Power: AC Coil: 4.0VA; DC Coil: 1.7W.
Coil Temp. Rise: 35°C/W.
Max. Coil Temp.: 155°C.
Duty Cycle: Continuous.
Coil Data (@ 25°C Coil Temperature)
Nom. Voltage
DC Resist.
( VDC )
±10% ( Ohms )
12
86
24
350
AC Coils ( 4.0VA )
Nom. Voltage
Freq.
DC Resist.
( VAC )
±10% ( Ohms )
12
60
9.1
24
60
36.6
Notes
(1) FLA, LRA ratings are compatible with 3.5 ton compressor applications.
(2) Nominal voltage, no coil suppression, excluding bounce.
P&B
File E22575 (type 2,3,4,5)
File No. 5386 (type 1,2,3,4)
T2
L2
T2
9
ohms, min. @ 500VDC.
DC Coils ( 1.7W )
Nom. Voltage
DC Resist.
( VDC )
±10% ( Ohms )
48
1,390
110
7 ,255
Nom. Voltage
Freq.
DC Resist.
( VAC )
±10% ( Ohms )
110/120
50/60
950
200/208
50/60
2,841
220/240
50/60
3,800
250/277
50/60
5,485
511

T92S11D22-24 Summary of contents

  • Page 1

    ... Initial Insulation Resistance Between Mutually Insulated Elements: 10 Coil Data Voltage: 12 through 110VDC and 12 through 277VAC. Resistance: See Coil Data table. Nom. Power: AC Coil: 4.0VA; DC Coil: 1.7W. Coil Temp. Rise: 35°C/W. Max. Coil Temp.: 155°C. Duty Cycle: Continuous. Coil Data (@ 25°C Coil Temperature) Nom ...

  • Page 2

    ... M4 screws with captive pressure plates for coil and contacts. (washable) plastic case 110 = 110VDC 240 = 220/240VAC 277 = 250/277VAC T92S7D12-12 T92S11D22-12 T92S7D12-24 T92S11D22-24 P&B 2 -24 ...

  • Page 3

    Outline Dimensions Mounting & Termination Type 1 2.06 MAX. (52.32) 1.21 MAX. (30.73) .156 (3.96) 1.618 ± .020 (41.10 ± .51) .585 ± .005 (14.86 ± .13) .032 TYP. .309 ± .005 (0.81) (7.85 ± .13) 1.000 ± .010 .630 ...