IM47TS TE Connectivity, IM47TS Datasheet

RELAY, DPST, C/O, 24V, LATCH

IM47TS

Manufacturer Part Number
IM47TS
Description
RELAY, DPST, C/O, 24V, LATCH
Manufacturer
TE Connectivity
Datasheet

Specifications of IM47TS

Coil Type
DC
Contact Configuration
DPDT
Contact Current Max
2A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
220V
Coil Voltage Vdc Nom
24V
Coil Resistance
2.88kohm
Coil Power Cont
200mW
Rohs Compliant
Yes
IM Series
AXICOM Signal and Telecom Relays

Related parts for IM47TS

IM47TS Summary of contents

Page 1

IM Series AXICOM Signal and Telecom Relays ...

Page 2

AXICOM Telecom, Signal and RF Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics and its affiliates ...

Page 3

AXICOM Telecom, Signal and RF Relays IM Relay IM Relay 1 and 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay ...

Page 4

AXICOM Telecom, Signal and RF Relays IM Relay Selection Guide IM-A IM-B 1 Pole break 1 Pole make 1 Form B 1 Form A SPST NC SPST NO IM-A High Dielectric “C” Relay Code IM All specifications subject to change. ...

Page 5

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – ...

Page 6

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard ...

Page 7

... IM40TS 5-1462037-0 90 IM41TS 5-1462037-3 203 IM42TS 5-1462037-6 250 IM43TS 5-1462037-8 360 IM44TS 6-1462037-1 810 IM45TS 3-1462037-2 1440 IM46TS 6-1462037-6 2880 IM47TS 6-1462037-9 23 IM40NS 1-1462038-8 90 IM41NS 1-1462038-9 203 IM42NS 2-1462038-0 250 IM43NS 2-1462038-1 360 IM44NS 2-1462038-2 810 IM45NS 2-1462038-3 1440 IM46NS 2-1462038-4 ...

Page 8

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High ...

Page 9

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Ultra ...

Page 10

AXICOM Telecom, Signal and RF Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Dimensions IM-A THT Version Standard Version Mounting Hole Layout View onto the ...

Page 11

AXICOM Telecom, Signal and RF Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 12

AXICOM Telecom, Signal and RF Relays IM-B Relay 1 Pole Make / 1 Form A / SPST NO Dimensions IM-B THT Version Standard Version Mounting Hole Layout View onto the ...

Page 13

AXICOM Telecom, Signal and RF Relays IM-B Relay 1 Pole Make / 1 Form A / SPST NO Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 14

AXICOM Telecom, Signal and RF Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Dimensions IM-C THT Version Standard Version Mounting Hole Layout View onto the component ...

Page 15

AXICOM Telecom, Signal and RF Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-C ...

Page 16

AXICOM Telecom, Signal and RF Relays IM-D Relay 2 Pole Break / 2 Form B / DPST NC Dimensions IM-D THT Version Standard Version Mounting Hole Layout View onto the ...

Page 17

AXICOM Telecom, Signal and RF Relays IM-D Relay 2 Pole break / 2 Form B / DPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 18

AXICOM Telecom, Signal and RF Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Dimensions IM-E THT Version Standard Version Mounting Hole Layout View onto the ...

Page 19

AXICOM Telecom, Signal and RF Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc ...

Page 20

AXICOM Telecom, Signal and RF Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting ...

Page 21

AXICOM Telecom, Signal and RF Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage ...

Page 22

AXICOM Telecom, Signal and RF Relays IM Relay Insulation IM Versions Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 ...

Page 23

AXICOM Telecom, Signal and RF Relays IM Relay High Frequency Data Capacitance between coil and contacts between adjacent contact sets between open contacts RF Characteristics Isolation at 100 MHz / 900 MHz Insertion loss at 100 MHz / 900 MHz ...

Page 24

AXICOM Telecom, Signal and RF Relays IM Relay Coil Operating Range 3.4 3 max. 2.8 2 2.4 max. 2 max. 1.6 ...

Page 25

AXICOM Telecom, Signal and RF Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended Reflow Soldering Profile Time (s) Resistance ...

Page 26

AXICOM Telecom, Signal and RF Relays IM Relay Packing Reel Dimension All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. K Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box ...

Page 27

AXICOM Telecom, Signal and RF Relays IM Relay IM Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from ...

Page 28

Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105 USA Phone +1 800-522-6752 www.tycoelectronics.com 108-98001 • Jul. 09 Rev. K • ECOC: JM10 Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 ...

Related keywords