3-1393243-3 TE Connectivity, 3-1393243-3 Datasheet

no-image

3-1393243-3

Manufacturer Part Number
3-1393243-3
Description
RTE44024
Manufacturer
TE Connectivity
Datasheet
n
n
n
n
n
n
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
05-2011, Rev. 0511
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Limiting continuous current
Limiting making current, max. 4s, duty factor 10%
Breaking capacity max.
Contact material
Frequency of operation, with/without load
Operate/release time max., DC coil
Bounce time max., DC coil, form A/form B
Electrical endurance
Contact ratings
Type
IEC 61810
RT424 DC coil C (CO)
RT444 AC coil A (NO)
RT424 AC coil C (CO)
UL 508
RT424 DC coil A/B (NO/NC) 10A, 250VAC, gen. purpose, 85°C
RT424 DC coil A/B (NO/NC) 1/2hp, 240VAC, 85°C
RT424 DC coil A/B (NO/NC) Pilot duty, B300, R300, 85°C
EN60947-5-1
RTE24 DC coil A/B (NO/NC) AC15, 250VAC, 3A
RTE24 DC coil A/B (NO/NC) DC13, 24VDC, 2A
RTE24 DC coil A/B (NO/NC) DC13, 250VDC, 0.2A
EN60730-1
RT424 DC coil A/B (NO/NC) 6(2)A, 250VAC, 85°C
1) For reflow solderable versions: actual contact performance may be influenced by the
2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
DC or AC coil
5kV/10mm coil-contact, reinforced insulation
Ambient temperature up to 85°C
WG version: product in accordance to IEC60335-1
Reflow version: for THR (Through-Hole Reflow) soldering process
DC coil
AC coil
reflow soldering process.
Contact
Load
8A, 250VAC, cosφ=1, 85°C
8A, 250VAC, cosφ=1, 70°C
8A, 250VAC, cosφ=1, 70°C
AgNi 90/10, AgNi 90/10 gold plated,
see electrical endurance graph
2 form C (CO) or 2 form A (NO)
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
360/72000h
360/36000h
8A, UL: 10A
8A, UL: 10A
250VAC
400VAC
AgSnO
2000VA
4/10ms
8/6ms
General Purpose Relays
PCB Relays
Power PCB Relay RT2
15A
2
-1
-1
100x10
10x10
50x10
30x10
20x10
Cycles
1)
1x10
6x10
6.050
6.050
6.050
3
3
3
3
3
3
3
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Contact Data
Mechanical endurance
Coil Data
Coil voltage range, DC coil/AC coil
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient
temperature +23°C. Other coil voltages on request.
Coil versions, AC coil 50Hz
3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient
temperature +23°C, 50Hz. Other coil voltages on request.
Coil
code
005
006
009
012
024
048
060
110
Coil
code
524
615
620
700
730
DC coil
DC coil, reflow version
AC coil
AC coil, reflow version
voltage
voltage
Rated
Rated
VDC
VAC
110
115
120
200
230
12
24
48
60
24
5
6
9
(continued)
Operate
Operate
150.0
172.5
voltage
voltage
16.8
33.6
42.0
77.0
18.0
86.3
90.0
VDC
VAC
3.5
4.2
6.3
8.4
V
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Release
Release
voltage
voltage
5 to 110VDC / 24 to 230VAC
11.0
17.3
18.0
30.0
34.5
VDC
VAC
Z
0.5
0.6
0.9
1.2
2.4
4.8
6.0
3.6
>30x10
>10x10
>5x10
>2x10
class F
6
6
resistance
resistance
b
Ω±10%
Ω±15%
6
6
28800
operations
operations
8570
24350
32500
operations
operations
2
1440
5520
350
8100
8800
200
360
Coil
Coil
62
90
SCHRACK
3)
2)
2)
2)
3)
Rated coil
Rated coil
F0149-C
power
power
0.76
0.76
0.75
0.76
0.74
mW
403
400
400
400
400
417
420
420
VA
1

Related parts for 3-1393243-3

Related keywords