CNT-35-26 TE Connectivity, CNT-35-26 Datasheet

no-image

CNT-35-26

Manufacturer Part Number
CNT-35-26
Description
Digital Multifunction Timer
Manufacturer
TE Connectivity
Type
Multifunction - 10 Functionsr
Datasheet

Specifications of CNT-35-26

Time Range
0.1 Sec. To 9990 Hr.
Time Range Min
0.1s
Peak Reflow Compatible (260 C)
No
Signal Input Type
Fixed Voltage
Supply Voltage Max
12VDC
Time Range Max
9990h
Rohs Compliant
No
Brand/series
CNT Series
Contact Form
DPDT
Current, Rating
10 A
Display Type
LCD
Function
Timing
Material, Contact
Silver-Cadmium Oxide Alloy
Mounting Type
Socket
Number Of Pins
11
Relay Type
Electro Mechanical
Standards
UL, CSA
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
Multi-Function
Timing Range
0.1 to 99.9 sec., 1 to 999 sec., 0.1 to 99.9 min., 1 to 999 min., 0.1 to 99.9 hrs., 1 to 999 hrs., 10 to 9990 hrs.
Tyco Part Number
1-1393124-5
Voltage, Control
12 VDC
Voltage, Rating
277⁄30 VAC⁄VDC
Fits 1.77 x 1.77 (45 x 45)
Panel cutout
Dimensions are shown for
reference purposes only.
Timing and Counting Modes
Timing Specifications
Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.;
Timing Adjustment: Digital adjustment via thumbwheel switches.
Tolerance:
Delta Time (for AC units add 1 cycle 60 Hz.):
Repeatability (Including first cycle of operation.):
Reset Time (power interruption): 45 ms, typ.; 60 ms, max.
Minimum Pulse Width, Control: 50 ms.
Recycle Time: 45 ms, typ.; 60 ms, max.
Counting Specifications
Maximum Count: 1 to 999; 10 to 9,990 ( 10); 100 to 99,900 ( 100).
Maximum Count Rate: 100 counts per second.
Mimumum Pulse Width:Count (Control): 3 ms.; Reset: 3 ms.
Available Counting Functions: Operate at preset count and release at
Contact Data @ 25 C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Initial Dielectric Strength
Between Open Contacts: 1,000V rms, 60 Hz.
Between All Other Conductors: 1,500V rms, 60Hz.
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
Universal Input Model
Fixed Input Models
Outline Dimensions
See the following page for a complete description of all program-
mable timing and counting modes.
(47 .8)
1.88
120VAC.
24-240VAC/VDC
A
Input Voltage
Input Voltage
1
0.5% 0.05 sec.
120VAC
(47 .8)
12VDC
1.88
1
0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr.
O
1
NC
H
N
preset count.
(8.1)
.32
Dimensions are in inches over
(millimeters) unless otherwise
specified.
(71.9)
2.83
0.1% 0.05 sec.
(80.0)
Part Number
3.15
Part Number
CNT-35-96
CNT-35-26
CNT-35-76
0.1% 0.05 sec.
(16.3)
.64
(44.7)
1.76
Catalog 1308242
Issued 3-03
CNT
Multifunction, Digital
Time Delay Relay/Counter
• 10 programmable timing modes + 2 counting modes
• 0.1 sec. to 9,990 hr. programmable timing range
• 1 to 99,900 counting range
• LCD digital display
• Universal (24-240VAC/VDC) and fixed input types
• 10A output relay with DPDT contacts
• Thumbwheel switches for programming
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25 C
Voltage: Universal Input Type: 24 - 240V 15%, 50/60 Hz. AC or DC.
Power Requirement:
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
Environmental Data
Temperature Range: Storage: -20 C to +70 C.
Humidity: 85% relative humidity, non-condensing.
Mechanical Data
Termination: 11-pin octal style plug.
Enclosure: Beige plastic 1/16 DIN case.
Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets.
Weight: 4.3 oz. (122g) approximately.
External Control: CONTROL, RESET: Active on contact closure or solid
Accessories
Wiring Diagrams (Bottom Views)
(pins numbered clockwise from keyway)
* Note: Input polarity for DC operation. For most reliable operation on AC, connect high side
** Important: A dry circuit switch is recommended. A “dry circuit” switch is one rated to
Input Voltages & Limits @ 25 C
EXTERNAL CONTROL SWITCHES**
Part Number
SSA-24C667
SSA-24C668 Protective Cover
Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC.
Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC.
RETURN
File E22575
File LR15734
Universal
AC models will operate on 50 or 60 Hz.
Specifications and availability
subject to change.
Fixed
Input
+
Type
to “+” and low side to “–”.
Fixed Input Types: 120VAC 15%, 50/60 Hz and 12VDC.
CONTROL
INPUT*
(COUNT)
1 11
reliably switch currents of less than 50mA. Use of a switch rated for other
than dry circuit may result in failure of the time delay relay to function properly.
series
Mounting Clip
state switch closure to RETURN, 0-1.0VDC maximum
voltage level (see wiring diagrams for interface circuits.
Name
_
RESET
24-240VAC/VDC
Operating: -10 C to +55 C.
Nominal
Voltage
10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC.
120VAC
12VDC
CNT to help protect against dust and moisture.
Clear, flexible cover slips snugly over bezel of
Durable cover also helps prevent inadvertant
Ratchet-fit clip slides onto CNT from behind
to secure CNT in panel mount applications.
changes of programming switch settings.
FOR RESET
USE SAME
20.4VAC/VDC
Minimum
10.2VDC
102VAC
Voltage
Description
CONTROL
RETURN
+
RESET
INPUT*
1
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
11
276VAC/VDC
Maximum
Voltage
_
13.8VDC
138VAC
P&B
1211

Related parts for CNT-35-26

CNT-35-26 Summary of contents

Page 1

... External Control: CONTROL, RESET: Active on contact closure or solid Accessories Part Number Part Number SSA-24C667 Mounting Clip CNT-35-96 SSA-24C668 Protective Cover Part Number CNT-35-26 CNT-35-76 Wiring Diagrams (Bottom Views) (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCHES** CONTROL (COUNT) RETURN 1.76 (44.7) ...

Page 2

Protective Cover & Mounting Clip Dimensions SSA-24C668 Protective Cover 1.99 (50.5) “A ” 1.99 (50.5) Section "A-A" “A ” Programming Switch Diagram Function Select: Timer Mode Delay On Operate B = Delay On Release C = Interval On ...

Related keywords