2007492-5 TE Connectivity, 2007492-5 Datasheet - Page 3

SFP CONNECTOR RECEPTACLE 40POS PRESS FIT

2007492-5

Manufacturer Part Number
2007492-5
Description
SFP CONNECTOR RECEPTACLE 40POS PRESS FIT
Manufacturer
TE Connectivity
Series
SFP+ Seriesr
Datasheets

Specifications of 2007492-5

No. Of Contacts
40
Connector Type
SFP+
Rohs Compliant
Yes
Product
SFP Connectors
Number Of Ports
2
Contact Plating
Gold
Contact Material
Copper Alloy
Mounting Style
Through Hole
Termination Style
Press Fit
Accessory
Cage Assembly, 2x1 Stacked
Color
Black
Flammability Rating
UL 94 V-0
Housing Material
Liquid Crystal Polymer (LCP)
Mounting Angle
Right
Product Type
Cage
Termination Type
Press-Fit
Configuration
2 x 1
Pcb Mount
Single Sided
Termination Post Length (mm [in])
3.00 [0.118]
Contact Plating, Mating Area, Material
Gold or Gold Flash over Palladium Nickel
Contact Base Material
Copper Alloy
Cage Type
Stacked
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Cage Material
Nickel Silver
Emi Containment
External Springs
Lightpipe
With
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Application
SFP+
Lightpipe Configuration
Four Per Column
Packaging Method
Tray
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2007492-5
Manufacturer:
TYCO
Quantity:
36 627
Part Number:
2007492-5
Manufacturer:
TE/泰科
Quantity:
20 000
Transceiver insertion force.
Transceiver extraction force.
Rotational cable pull.
Press- fit insertion force.
Press-fit extraction force.
Cage latch strength/module
retention.
Reseating.
Mate/unmate.
Thermal shock.
Rev A
Test Description
18 N [4.0 lbf] maximum.
12.5 N [2.8 lbf] maximum.
33.4 N [7.5 lbf] minimum without
displacement of cage assembly or
connector from Printed Circuit
Board (PCB).
4.4 kN [1000 lbf] maximum for 2X4
connector/cage assembly.
800 N [180 lbf] minimum for 2X4
connector/cage assembly.
90 N [20.2 lbf] minimum.
See Note.
See Note.
See Note.
Figure 1 (continued)
ENVIRONMENTAL
Requirement
EIA-364-13.
Measure force necessary to insert
the transceiver into the receptacle
with kick-out springs inoperable at a
maximum rate of 12.7 mm [.5 in] per
minute.
EIA-364-13.
Measure force necessary to extract
the transceiver from the receptacle
with kick-out springs inoperable at a
maximum rate of 12.7 mm [.5 in] per
minute.
Load cabled module into
cage/connector assembly applied to
PCB with attached bezel. Rotate
cable 40 degrees toward PCB, and
then rotate 360 degrees with the
load still applied.
Measure force necessary to press
the specimen onto the PCB into
proper seating location at a
maximum rate of 12.7 mm [.5 in] per
minute.
Measure force necessary to extract
the specimen from the PCB at a
maximum rate of 12.7 mm [.5 in] per
minute.
Load cable module into
cage/connector assembly applied to
PCB with attached bezel. Apply
specified axial load to engaged
module at a maximum rate of 6.35
mm [.25 in] per minute and hold for
1 minute to verify module retention
and cage latch strength.
Unmate and mate specimens 3
times.
Unmate and mate specimens 1
time.
EIA-364-32, Test Condition VII.
Subject mated specimens to 5
cycles between -55 and 105°C with
30 minute dwells at temperature
extremes and 1 minute transition
between temperatures.
Procedure
108-2331
3 of 6

Related parts for 2007492-5