D4GSN2R3 Omron, D4GSN2R3 Datasheet

no-image

D4GSN2R3

Manufacturer Part Number
D4GSN2R3
Description
Manufacturer
Omron
Type
Safety-Door Switchr
Datasheet

Specifications of D4GSN2R3

Switch Function Configuration
N.C.
Current Rating (max)
0.75A
Operating Temp Range
-30C to 70C
Lead Free Status / Rohs Status
Compliant
Slim Safety Door Switches with IP67 Rating
Model Number Structure
Model Number Legend
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
Consult with your OMRON representative when ordering any models that are not listed in this table.
Operation Keys
Switch
D4GS-N@@-@
Horizontal mounting
Vertical mounting
• Slim design with a width of only 17 mm
• Reversible design allowing either front or rear mounting.
• Built-in Switches with two- or three-terminal contact
• Operation Key with rubber mounting hole to absorb vibration and
• IP67 degree of protection.
1. Built-in Switch
Slim Safety Door Switch
D4GS-N
(three-contact models).
construction are available.
shock.
Appearance
1: 1NC/1NO (slow-action)
2: 2NC (slow-action)
3: 2NC/1NO (slow-action)
4: 3NC (slow-action)
Be sure to read the “Safety Precautions” on page 8 and the
“Precautions for All Safety Door Switches”.
Type
1 2 3
Operation Key
Direction of
Horizontal
insertion
Vertical
D4GS-NK1
D4GS-NK2
Model
2. Direction of Operation
Key Insertion
R: Horizontal
T:
Cable length
Vertical
1 m
3 m
5 m
1 m
3 m
5 m
Adjustable mounting
(Vertical)
D4GS-N1R
D4GS-N1R-3
D4GS-N1R-5
D4GS-N1T
D4GS-N1T-3
D4GS-N1T-5
Type
(Slow-action)
1NC/1NO
3. Cable Length
Blank: 1 m
3:
5:
D4GS-N2R
D4GS-N2R-3
D4GS-N2R-5
D4GS-N2T
D4GS-N2T-3
D4GS-N2T-5
.
3 m
5 m
(Slow-action)
D4GS-NK4
Model
2NC
: Models with certified direct opening contacts.
1. Operation Key Type
Operation Key
D4GS-NK@
1: Horizontal mounting
2: Vertical mounting
4: Adjustable mounting (Vertical)
D4GS-N3R
D4GS-N3R-3
D4GS-N3R-5
D4GS-N3T
D4GS-N3T-3
D4GS-N3T-5
(Slow-action)
2NC/1NO
1
CSM_D4GS-N_DS_E_5_1
D4GS-N4R
D4GS-N4R-3
D4GS-N4R-5
D4GS-N4T
D4GS-N4T-3
D4GS-N4T-5
(Slow-action)
3NC
1

Related parts for D4GSN2R3

D4GSN2R3 Summary of contents

Page 1

... R: Horizontal 3: 2NC/1NO (slow-action 3NC (slow-action) Ordering Information List of Models Switches (Operation Keys are sold separately.) Consult with your OMRON representative when ordering any models that are not listed in this table. Direction of Appearance Operation Key insertion Horizontal Vertical Operation Keys ...

Page 2

... Certification for CSA C22.2 No authorized by the UL mark. DC-13 0.27 A 250 V Current (A) Make Break 15 1.5 7.5 0.75 Current (A) Make Break 0.55 0.55 0.27 0.27 D4GS-N Standard File No. EN60947-5-1 Consult your OMRON representative for opening) details. GS-ET-15 UL508 E76675 GB14048.5 2003010305064262 Volt-amperes (VA) Make Break 1,800 180 Volt-amperes (VA) Make Break ...

Page 3

... Switch damage or malfunctioning may occur. *2. The durability conditions are an ambient temperature 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. When the ambient temperature is 35°C or higher, do not apply 125 VAC to more than one circuit. ...

Page 4

... Structure and Nomenclature Structure Head The insertion direction of the Operation Key can be changed to either vertical or horizontal. (The figure shows a horizontal insertion.) Built-in Switch Switches are available with contacts. Contact Form (Diagrams Show State with Key Inserted.) Model Contact Contact form D4GS-N1@-@ 1NC/1NO 11 ...

Page 5

... Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Dimensions in parentheses are reference values. 2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application. (Operation Key center position) ...

Page 6

Operation Keys D4GS-NK1 Two, 4.3 dia. Red 1.4 (Operation Key center position) D4GS-NK4 Black Adjusting screw (Set screw with M4 hexagonal hole) Four, 8R Two, 8 dia. Two, 4.2 dia. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies ...

Page 7

D4GS-N@R-@ + D4GS-NK2 Red Black 5.4 to 7.9 Key insertion position 5.4 to 7.9 5.4 to 7.9 Key insertion face Key insertion Key position insertion position ± (41 Key insertion radius (R ≥ 160) * Mount with dimension ...

Page 8

... Safety Precautions Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”. Precautions for Safe Use • Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time ...

Page 9

... Switch and Operation Key, and tighten the screws to the proper tightening torque. To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and Operation Key from easily being removed. Mounting Hole Dimensions for Switches Two, M4 20±0.1 or 22±0.1 Mounting Hole Dimensions for Operation Keys ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords