Specifications of MT29F8G08ABABAWP-IT:B

Cell Type
NAND
Density
8Gb
Interface Type
Parallel
Boot Type
Not Required
Address Bus
30b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
1G
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
VITESSE
Quantity:
101
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
MICRON
Quantity:
4 000
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
MICRON/美光
Quantity:
20 000
Company:
Part Number:
MT29F8G08ABABAWP-IT:B
Quantity:
1 000
SYNCHRONOUS RESET (FCh)
Figure 29:
PDF: 09005aef8386131b / Source: 09005aef838cad98
m61a_async_sync_nand.fm - Rev. A 2/09 EN
SYNCHRONOUS RESET (FCh) Cycle
When the synchronous interface is active, the SYNCHRONOUS RESET (FCh) command
is used to put a target into a known condition and to abort a command sequence in
progress. This command is accepted by all LUNs, even when they are BUSY.
When FCh is written to the command register, the target goes busy for
the selected target (CE#) discontinues all array operations on all LUNs. All pending
single-plane and multi-plane operations are cancelled. If this command is issued while a
PROGRAM or ERASE operation is occurring on one or more LUNs, the data may be
partially programmed or erased and is invalid. The command register is cleared and
ready for the next command. The data register and cache register contents are invalid,
and the synchronous interface remains active.
During or after
SYNCHRONOUS RESET is only accepted while the synchronous interface is active. Its
use is prohibited when the asynchronous interface is active.
DQ[7:0]
W/R#
R/B#
DQS
CE#
ALE
CLK
CLE
t CS
Micron Confidential and Proprietary
t
RST, the host can poll each LUN's status register.
8Gb Asychronous/Synchronous NAND Flash Memory
t CAD
RESET command
SYNCHRONOUS
t CALS
t CAS
FCh
t CAH
t CALH
42
t CALS
t WB
Micron Technology, Inc., reserves the right to change products or specifications without notice.
t CALH
t CALH
t CH
t RST
Command Definitions
©2008 Micron Technology, Inc. All rights reserved.
Don’t Care