MT29F8G08ABABAWP-IT:B Micron Technology Inc, MT29F8G08ABABAWP-IT:B Datasheet - Page 57

no-image

MT29F8G08ABABAWP-IT:B

Manufacturer Part Number
MT29F8G08ABABAWP-IT:B
Description
MICMT29F8G08ABABAWP-IT:B 8GB ASYNCHRONOU
Manufacturer
Micron Technology Inc
Datasheet

Specifications of MT29F8G08ABABAWP-IT:B

Cell Type
NAND
Density
8Gb
Interface Type
Parallel
Boot Type
Not Required
Address Bus
30b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
1G
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
VITESSE
Quantity:
101
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
MICRON
Quantity:
4 000
Part Number:
MT29F8G08ABABAWP-IT:B
Manufacturer:
MICRON/美光
Quantity:
20 000
Company:
Part Number:
MT29F8G08ABABAWP-IT:B
Quantity:
1 000
Table 14:
READ STATUS (70h)
Figure 36:
SELECT LUN WITH STATUS (78h)
PDF: 09005aef8386131b / Source: 09005aef838cad98
m61a_async_sync_nand.fm - Rev. A 2/09 EN
SR
Bit
1
0
Definition
FAILC
FAIL
Status Register Definition (continued)
READ STATUS (70h) Operation
Notes:
Independent
per Plane
1. After a multi-plane operation begins, the FAILC and FAIL bits are ORed together for the
The READ STATUS (70h) command returns the status of the last-selected LUN on a
target. This command is accepted by the last-selected LUN even when it is busy
(RDY = 0).
If there is only one LUN per target, the READ STATUS (70h) command can be used to
return status following any NAND command.
In devices that have more than one LUN per target, during and following multi-LUN
operations, the SELECT LUN WITH STATUS (78h) command must be used to select the
LUN that should report status. In this situation, using the READ STATUS (70h) command
will result in bus contention, as two or more LUNs could respond until the next opera-
tion is issued. The READ STATUS (70h) command can be used following all single-LUN
operations.
The SELECT LUN WITH STATUS (78h) command returns the status of the addressed
LUN on a target even when it is busy (RDY = 0). This command is accepted by all LUNs,
even when they are BUSY (RDY = 0).
I/O[7:0] (DQ[7:0])
Yes
Yes
active planes when the READ STATUS (70h) command is issued. After the SELECT LUN WITH
STATUS (78h) command is issued, the FAILC and FAIL bits reflect the status of the plane
selected.
Cycle type
1
Pass/Fail (N-1):
"0" = Pass
"1" = Fail
This bit is set if the previous operation on the selected LUN failed. This bit is valid
only when RDY (SR bit 6) is "1." It applies to PROGRAM-, ERASE-, and COPYBACK
PROGRAM-series operations (80h-10h, 80h-15h, 60h-D0h, 85h-10h). This bit is not
valid following a READ-series operation.
Pass/Fail (N):
"0" = Pass
"1" = Fail
This bit is set if the most recently finished operation on the selected LUN failed.
This bit is valid only when ARDY (SR bit 5) is "1." It applies to PROGRAM-, ERASE-,
and COPYBACK PROGRAM-series operations (80h-10h, 80h-15h, 60h-D0h, 85h-
10h). This bit is not valid following a READ-series operation.
Micron Confidential and Proprietary
Command
8Gb Asychronous/Synchronous NAND Flash Memory
70h
t WHR
57
D
SR
OUT
Micron Technology, Inc., reserves the right to change products or specifications without notice.
Description
Command Definitions
©2008 Micron Technology, Inc. All rights reserved.
Advance