LY2FAC220240 Omron, LY2FAC220240 Datasheet

Electromechanical Relay DPDT 10A 220/240VAC 18.79KOhm Flange Mount

LY2FAC220240

Manufacturer Part Number
LY2FAC220240
Description
Electromechanical Relay DPDT 10A 220/240VAC 18.79KOhm Flange Mount
Manufacturer
Omron
Type
General Purpose Relayr
Datasheets

Specifications of LY2FAC220240

Contact Arrangement
DPDT
Ac Coil Voltage
220|240 V
Coil Current
4.2|4.6 mA
Mounting
Flange Mount
Relay Construction
Non-Latching
Contact Form
2 Form C
Coil Voltage Ac
220V/240V
Voltage Rating (vdc)
125V
Voltage Rating (vac)
250V
Dropout Volt (min)
72VACV
Coil Resistance
18.79kohm
Pick-up Voltage (max)
192VAC
Maximum Power Rating
240W/1.1KVA
Operate Time
25ms
Contact Current Rating
10A
Contact Material
Silver
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
42mm
Product Depth (mm)
22.5mm
Product Length (mm)
44mm
Operating Temp Range
-25C to 55C
Pin Count
8
Mounting Style
Flange
Termination Style
Quick Connect
Package / Case
Dust Cover
Lead Free Status / Rohs Status
Compliant
A Miniature Power Relay
Ordering Information
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Standard
With built-in diode
(DC only)
With built-in CR
(AC only)
General Purpose Relay – LY
442
Equipped with arc barrier.
Dielectric strength: 2,000 V.
Built-in diode models added to the LY Series.
Single-pole and double-pole models are
applicable to operating coils with ratings of
100/110 VAC, 110/120 VAC, 200/220 VAC,
220/240 VAC, or 100/110 VDC).
Three-pole and four-pole models are
applicable to operating coils with ratings of
100/110 VAC, 200/220 VAC, or 100/110 VDC).
Open Relays
2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON
3. SEV models are standard Relays excluding DPDT (bifurcated) models.
4. VDE- or LR- qualifying Relays must be specified when ordering.
Type
representative for details.
Example: LY2, 6 VAC
SPDT
DPDT
DPDT (bifurcated)
3PDT
4PDT
SPDT
DPDT
DPDT (bifurcated)
3PDT
4PDT
SPDT
DPDT
DPDT (bifurcated)
Contact form
LY1
LY2
LY2Z
LY3
LY4
LY1-D
LY2-D
LY2Z-D
LY3-D
LY4-D
LY2-CR
LY2Z-CR
Rated coil voltage
Plug-in/solder
terminals
LY1N
LY2N
LY2ZN
LY3N
LY4N
LY1N-D2
LY2N-D2
LY2ZN-D2
LY4N-D2
LY2N-CR
LY2ZN-CR
Plug-in/solder
terminals with
LED indicator
LY1-0
LY2-0
LY2Z-0
LY3-0
LY4-0
PCB terminals
R
C+
LY1F
LY2F
LY2ZF
LY3F
LY4F
Upper-mounting
plug-in/solder
terminals
V D E
LR

Related parts for LY2FAC220240

LY2FAC220240 Summary of contents

Page 1

... Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table. Example: LY2, 6 VAC 2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON representative for details. ...

Page 2

... PT11 PTP-1-3 PT11QN PT14 PTP-1 PT14QN Socket-Hold-down Clip Pairings Relay type Poles Standard, bifurcated 1, 2 contacts operation 3 indicator, built-in diode 4 CR Circuit 2 Specifications Coil Rating ■ Single- and Double-pole Relays Rated voltage Rated current 214.1 mA 183 106 53 25 100/110 V 11.7/12.9 mA 10/11 mA 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 Ω ...

Page 3

... 100/110 V 14.1/16 mA 12.4/13.7 mA 2,300 Ω 200/220 V 9.0/10.0 mA 7.7/8 234 112 58 28.2 mA 100/110 V 12.7/13 mA Note: See notes under next table. Four-pole Relays Rated voltage Rated current 386 mA 330 199 mA 170 93 46 100/110 V 22.5/25.5 mA 19/21.8 mA 1,600 Ω 200/220 V 11.5/13.1 mA 9.8/11.2 mA 6,700 Ω ...

Page 4

... Operating 85% Weight Single- and double-pole: approx three-pole: approx four-pole: approx Note: 1. The values given above are initial values 2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element used. Single Contact 2 4-pole Resistive load Inductive load (cosϕ ...

Page 5

General Purpose Relay – LY Endurance Under Real Loads (reference only) ■ LY1 Rated voltage Load type 100 VAC AC motor AC lamp Capacitor (2,000 µF) AC solenoid LY2 Rated voltage Load type 100 VAC AC motor AC lamp Capacitor ...

Page 6

General Purpose Relay – LY Approved Standards ■ UL 508 Recognitions (File No. 41643) No. of poles 240 VAC 6 to 125 VDC 2 3 and 4 CSA 22.2 No. 14 Listings (File No. LR31928) No. of ...

Page 7

General Purpose Relay – LY Approved Standards (cont.) ■ LR Recognitions (No. 563KOB-204523) No. of poles 240 VAC 6 to 110 VDC Engineering Data LY1 Maximum Switching Power (cosφ = 0.4) 1 ...

Page 8

... DC resistive load 1 0 Life: 500,000 operations 10 50 100 Switching voltage (V) Dimensions Note: All units are in millimetres unless otherwise indicated. Relays with Solder/Plug-in Terminals ■ LY1 LY1N (-D2) LY1-D Eight, 2-dia. holes 3 36 max. 6.4 Note: The DC models have polarity. AC resistive load AC (cosφ ...

Page 9

General Purpose Relay – LY LY2 LY2Z LY2-D LY2Z-D LY2N LY2ZN LY2N-D2 LY2ZN-D2 Eight, 3-dia. holes 3 36 max. 6.4 LY2(Z)N DC Model Note: The DC models have polarity. LY3 LY3N LY3-D 36.5 max. 6.4 LY3 Note: The DC models ...

Page 10

... LY2-CR LY2Z-CR LY2N-CR LY2ZN-CR 0.5 Eight, 3-dia. holes max. 6.4 Model: LY2N-CR Relays with PCB Terminals ■ LY1-0 LY3-0 LY2-0 LY4-0 0 max. 4.5 (see note 2) Note: 1. The above model is the LY2-0. 2. This figure is 6.4 for the LY1-0 Terminal Arrangement/Internal Connections 0.5 28 max ...

Page 11

... General Purpose Relay – LY Upper Mounting relays ■ LY1F LY2F 2 35.5 max. Note: 1. Eight 3-dia. holes should apply to the LY2F model. LY3F 2 36 max. LY4F 2 35.5 max. 452 22.5 max. 0.5 44 max max Eight, 2-dia. holes (see note) 6.4 3.5 32 max. ...

Page 12

General Purpose Relay – LY Mounting Height with Socket ■ The following Socket heights should be maintained. Back-connecting Front-connecting LY 40 (57) 67 (84) 71 (see note) PTF@A (-E) Sockets ■ PTF08A-E PTF11A PTF14A-E PT14QN PT11QN Mounting Plates for Back-connecting ...

Page 13

... General Purpose Relay – LY Hold-down Clips ■ Hold-down clips are used to hold Relays to Sockets and prevent them from coming loose due to vibration or shock. Used with Socket PYC-A1 PYC-P Precautions Connections ■ Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators. ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords