TDH-6050-3000 Leach International, TDH-6050-3000 Datasheet

no-image

TDH-6050-3000

Manufacturer Part Number
TDH-6050-3000
Description
Electromechanical Relay DPDT 10A 20/30VDC Socket
Manufacturer
Leach International
Type
Time Delay Relayr
Datasheet

Specifications of TDH-6050-3000

Contact Arrangement
DPDT
Dc Coil Voltage
20/30 V
Coil Current
150 mA
Mounting
Socket
DESCRIPTION
Date of issue: 3/06
The TDH-6050/51 Time Delay Relays have been designed with thick film hybrid microelectronics timing circuits
and MIL-PRF-6106 relays, packaged in a hermetically sealed military style enclosure. The TDH-6050/51 series
are designed to withstand severe environmental conditions encountered in military/aerospace applications. These
relays are suited for use in power control, communication circuits and many other applications where power
switching and high reliability are required over a wide temperature range.
ENGINEERING DATA SHEET
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Featuring
www.esterline.com
APPLICATION NOTES:
101
APPLICABLE SOCKETS:
S302
LEACH
©
power and control solutions
FEATURES
PRINCIPLE TECHNICAL CHARACTERISTICS
Seal:Hermetic Tested per MIL-STD-883,
Method 1014 Condition B, C
Finish: per MIL-T-10727
Terminals:
TDH 6051 (Tin Plate)
TDH 6050 (Gold Plate)
Weight
Small size and weight
High-reliability design
Hermetically sealed
High transient immunity
Long life
Low-power consumption
Reverse Polarity Protection
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
- 42 -
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ON OPERATE-FIXED PERIOD
TDH-6050/6051
1x10
leakage
Tin Plate
Solder-lug
Plug-In
1.9 Ounce max.
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
-8
atm, cm
2 PDT, 10 AMP
3
/s max
Page 1 of 3

Related parts for TDH-6050-3000

TDH-6050-3000 Summary of contents

Page 1

... APPLICABLE SOCKETS: S302 DESCRIPTION The TDH-6050/51 Time Delay Relays have been designed with thick film hybrid microelectronics timing circuits and MIL-PRF-6106 relays, packaged in a hermetically sealed military style enclosure. The TDH-6050/51 series are designed to withstand severe environmental conditions encountered in military/aerospace applications. These relays are suited for use in power control, communication circuits and many other applications where power switching and high reliability are required over a wide temperature range ...

Page 2

... GENERAL CHARACTERISTICS Ambient Temperatures Range: a. Operating b. Non-Operating Vibration: a. Sinusoidal, 10-2000 Hz b. Random: 50-2000 Hz, MIL-STD-810 Shock @ 6 ± 1 MS, 1/2 Sine, 3 Axis Acceleration, in any Axis Life at Rated Resistive Load; Minimum NUMBERING SYSTEM Plug-in Terminal TDH-6050 - 1001 | | | Model Number. 2. Pin Style Number. 3. Timing Range, Fixed: 100 milliseconds to 600 seconds. (See Note 6). ...

Page 3

... PLACES .200 TYPICAL CONTRASTING BEAD DETAIL VIEW B - 2502 = 25 seconds (25,000 milliseconds) - 5000 = 0.5 seconds (500 milliseconds - +X1 .04 CONTRASTING BEAD FIXED TIME DELAY .15 20-30 VDC X1-X2 0 VDC INPUT VOLTAGE .10 .20 TIME DELAY DE-ENERGIZED RELAY OUTPUT TIME DELAY ON OPERATE TDH-6050/6051 ENERGIZED Page ...

Page 4

Application notes DERATING OF CONTACTS FOR DC VOLTAGES To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay ...

Page 5

... Featuring LEACH power and control solutions www.leachintl.com Data sheets are for initial product selection and comparison. Contact Leach International prior to choosing a component. Date of issue: 8/08 BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 M 22520/2-01 with turret M 22520/2-14 ...

Page 6

... MOUNTING TORQUE:0,45 ±0,1 Nm :3,6 mm CODE 7 : 05-284-15 LOOSE METRIC HARDWARE TOP MOUNT MOUNTING TORQUE:0,45 ±0,1 Nm FOR RELAYS WITH CODE B TERMINALS MOUNTING HOLE:3,6 mm CODE 8 : 05-284-20 FIXED UNC STUDS PER MIL-S-12883/41 - EDIT C BOTTOM MOUNT MOUNTING TORQUE: NUT 4/40:0,45 ±0 NUT 10-32: 1,2 MAX MOUNTING HOLE: 5,3 mm S300, S301, S302 ± ...

Page 7

WIRE INSULATION DIAMETER FOR SEAL TO GROMMET Code A Recommended for contact code 2 contact code 8 Dia: 1.2 ......2.4mm CONTACT SIZE AND STYLE Y1-Y2 Crimpend to accomodate AWG22 05 912 00 (for product code 2+3) Contact mating end dia ...

Page 8

... MS/LEACH CROSS PART NO. AND MATING RELAYS MS - Number LEACH P/N Contacts to accomodate wire # -01 -04 MIL-S-12883/41 -02 - Number LEACH P/N Contacts to accomodate wire # -11 -14 MIL-S-12883/41B -12 - Number LEACH P/N Contacts to accomodate wire # -11S -14S -12S MIL-S-12883/41C -13S -15S -16S -19S -17S MIL-S-12883/41C -18S -20S Date of issue: 3/06 ...