Electromechanical Relay SPDT 15A 12VDC 650Ohm Through Hole

1393223-3

Manufacturer Part Number
1393223-3
Description
Electromechanical Relay SPDT 15A 12VDC 650Ohm Through Hole
Manufacturer
TE Connectivity
Type
General Purpose Relayr
Datasheets

Specifications of 1393223-3

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
18.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Voltage Rating (vac)
400V
Dropout Volt (min)
1.2VDCV
Coil Resistance
652Ohm
Pick-up Voltage (max)
8.6VDC
Maximum Power Rating
2KVA
Operate Time
10ms
Contact Current Rating
15A
Contact Material
Silver Cadmium Oxide
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
15mm
Product Depth (mm)
10mm
Product Length (mm)
30mm
Operating Temp Range
-40C to 85C
Pin Count
5
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant
1248
Design Features
• Available in on-delay, true off-delay, and on/off-delay.
• Timing from 0.1 seconds to 60 minutes, in linear increments.
• Oversize time-calibrated adjustment knobs, serrated with high-resolution
• Inherent transient immunity.
• Standard voltages from 6-550VAC and 12-550VDC (special voltages available.)
• Available in 2-pole or 4-pole models.
• Numerous enclosure options:
• Auxiliary timed and instantaneous switches can be added for greater switching
• Many mounting options: Surface mount, Panel mount, Octal plug-in mounting.
• Options: quick-connect terminals, dial stops, and transient protection module.
• Easy-to-reach screw terminals, all on the face of the unit, clearly identified.
• Modular assembly - timing head, coil assembly and switchblock are all
Design & Construction
controlled pressure through a variable orifice to provide linearly adjustable
timing. Patented design provides instant recycling, easy adjustment and long
service life under severe operating conditions.
with minimum current drain. Total sealing without external leads eliminates
moisture problems, gives maximum insulation value.
mechanism provides greater contact pressure up to transfer time for
positive, no flutter action. Standard switches are DPDT arrangement, with
flexible beryllium copper blades and silver-cadmium oxide contacts. Special
"timing-duty" design assures positive wiping action, sustained contact pres-
sure and greater heat dissipation during long delay periods.
then assembled at the factory with the other two to afford a wide choice of
operating types, coil voltages, and timing ranges.
grouping of Series 7000 units side-by-side in minimum panel space.
Auxiliary switches may be added in the base of the unit, without affecting
the overall width or depth.
Operation
“On-Delay” models provide a delay period on energization, at the end of
which the switch transfers the load from one set of contacts to another. De-
energizing the unit during the delay period immediately recycles the unit,
readying it for another full delay period on re-energization.
energization, and the delay period does not begin until the unit is de-
energized. At the end of the delay period the switch returns to its original po-
sition. Re-energizing the unit during the delay period immediately resets the
timing, readying it for another full delay period on de-energization. No power
is required during the timing period.
sequential delays on pull-in and drop-out in one unit. With the addition of
auxiliary switches the basic models provide two-step timing, pulse actuation
for interlock circuits, or added circuit capacity.
Dimensions are shown for
reference purposes only.
NOTE: Seismic & radiation tested E7000 models are available.
markings visible from all angles makes the timer easy to set timers.
hermetically-sealed, NEMA 1.
flexibility.
individual modules, with switches field-replaceable.
There are three main components of Series 7000 Timing Relays:
Calibrated Timing Head uses no needle valve, recirculates air under
Precision-Wound Potted Coil module supplies the initial motive force
Snap-Action Switch Assembly - custom-designed over-center
Each of these subassemblies forms a self-contained module which is
The squared design with front terminals and rear mounting permits the
Two basic operating types are available.
In "Off-Delay" models the switch transfers the load immediately upon
In addition to these basic operating types, "Double-Head" models offer
Consult factory for detailed information.
explosion proof, dust tight, watertight,
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Issued 3-03 (PDF Rev. 10-07)
Catalog 1308242
7000
Industrial Electropneumatic
Timing Relay
Note:7032 types and certain models with accessories are not agency approved.
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent
approvals files of the agencies/laboratories and review them to confirm the
product meets the requirements for a given application.
Consult factory for ordering information.
On-delay model 7012 (delay on pickup)
Off-delay model 7022 (delay on dropout)
be added to either on-delay or off-delay types. They switch additional circuits,
provide two-step timing action, or furnish electrical interlock for sustained coil
energization from a momentary impulse, depending on the type selected and
its adjustment. Because of their simple attachment and adjustment features,
they can be installed at the factory or in the field, by any competent mechanic.
All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480
VAC. A maximum of one Code T or two Code L auxiliary switches may be
added to each relay. The L or LL switch is available with on-delay relays only.
The T switch is available with both the on-delay and off-delay relays.
Auxiliary Switch Options for On-Delay
Instant Transfer (Auxiliary Switch Code L,
maximum of 2 per relay.)
1. Energizing coil begins time delay and transfers auxiliary switch.
2. Main switch transfers after total preset delay.
3. De-energizing coil resets both switches instantly.
Auxiliary switch is nonadjustable.
Two-Step Timing (Auxiliary Switch Code T,
maximum of 1 per relay.)
Specifications and availability
subject to change.
To increase the versatility of the basic timer models, auxiliary switches may
File E15631
series
File LR29186
Applying continuous voltage to the coil
(L1-L2) starts a time delay lasting for
the preset time. During this period the
normally closed contacts (3-5 and 4-6)
remain closed. At the end of the delay
period the normally closed contacts
break and the normally open contacts
(1-5 and 2-6) make. The contacts re-
main in this transferred position until
the coil is deenergized, at which time
the switch instantaneously returns to
its original position.
or after the delay period, will recycle
the unit within 50 msec.
It will then provide a full delay period
upon re-energization, regardless of
how often the coil voltage is interrupt-
ed before the unit has been permitted
to "time-out" to its full delay setting.
Applying voltage to the coil (for at
least 50 msec) will instantaneously
transfer the switch, breaking the nor-
mally closed contacts (1-5 and 2-6),
and making the normally open
contacts (3-5 and 4-6). Contacts
remain in this transferred position as
long as the coil is energized. The
time delay begins immediately upon
de-energization. At the end of the de-
lay period the switch returns to its
normal position.
delay period will immediately return
the timing mechanism to a point
where it will provide a full delay
period upon subsequent de-
energization. The switch remains in
the transferred position.
De-energizing the coil, either during
Re-energizing the coil during the
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
AGASTAT

Related parts for 1393223-3

1393223-3 Summary of contents

Page 1

... All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC. A maximum of one Code T or two Code L auxiliary switches may be added to each relay. The switch is available with on-delay relays only. The T switch is available with both the on-delay and off-delay relays. ...

Page 2

... All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480 VAC. A maximum of one Code T or two Code L auxiliary switches may be added to each relay. The switch is available with on-delay relays only. The T switch is available with both the on-delay and off-delay relays. ...

Page 3

Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified). Operating Modes: Model 7012/7014: On-delay (delay on pick-up). Model 7022/7024: Off-delay (delay on drop-out). Model 7032: On-delay, off-delay (double head). Timing Adjustment: Timing is set by ...

Page 4

Outline Dimensions (Dimensions in inches). Models 7012, 7022 Panel mount Option "X" Dimensions are shown for Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 10-07) Models 7014, 7024 Surge/Transient Protection ...

Page 5

Ordering Information 1. Basic Series 7000 series electropneumatic timing relay 2. Operation On-delay 3 = On-delay, off-delay (double head Off-delay 3. Contact Arrangement 2PDT (2 form C) **4 = 4PDT (4 form ...

Page 6

Ordering options – can only be orderd as factory installed options A1 – Single Quick-Connect Terminals GZ – Total Enclosure With knockouts for bottom connection. 3.16" 3.84" 7.63"H K – Explosion proof Enclosure (Meets requirements for ...