LPQ113 Astec Power, LPQ113 Datasheet

no-image

LPQ113

Manufacturer Part Number
LPQ113
Description
AC/DC Power Supply Quad-OUT 5V/15V/-15V/V to 25V 11A/5A/1A/3A 110W 19-Pin
Manufacturer
Astec Power
Datasheet

Specifications of LPQ113

Input Voltage
85 to 264 V
Output Voltage
5|15|-15|±5 to 25 V
Maximum Current Rating
2.5(rms) A
Maximum Output Current
11|5|1|3 A
Number Of Outputs
4
Maximum Output Power
110 W
Efficiency
70(Typ) %
Input Frequency
47 to 440 Hz
Operating Temperature
0 to 50 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPQ113
Manufacturer:
MITSUBISH
Quantity:
1 000
LPQ110 Series
110 Watts
Special Features
• Universal input
• High efficiency
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5 V output
• Overvoltage protection
• Overload protection
• A djustable floating 4th output
• Power fail
• Optional L bracket (-B suffix)
• Cover kit available LPX110-C
Total Power:
Input Voltage:
# of Outputs:
VDE
UL
CSA
NEMKO E N 60950/EMKO-TUE
BABT EN60950/BS7002
CB
CE
Safety
(On LPQ112 and LPQ113)
0805/EN60950 (IEC950)
11774-3336-1245
(LC #84997)
UL1950 E132002
CSA 22.2-234 Level 3
LR53982C
P94102464 (74-sec) 203
PS/605823
Certificate and report
1423, 1424, 1425
Mark (LVD)
80 - 110 Watts
85-264 VAC
120-300 VDC
Quad
Electrical Specifications
Input
Input ra n ge
Frequency
Inrush current
Efficiency
EMI filter
Safety ground
leakage current
Output
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection 5 .7 - 6.7 VDC on main output. Latching type, recycle AC to reset
85 - 264 Vac; 120 - 300 Vdc
47 - 440 Hz
< 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac, cold start @ 25 °C
70% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
0.5 mA @ 50/60 Hz, 264 Vac input
80 W convection 110 W with 30 CFM forced air
± 5% min. on main; 5 - 25 V on 4th output on LPQ112 and LPQ113
± 2% on output 1; ±3% on outputs 2, 3 & 4
20 ms @ 80 W load, 115 VAC nominal line
S hort circuit protection on all outputs. Case overload protected @ 110-145%
above peak rating
Embedded Power for
Business-Critical Continuity
LPQ110 Series
Rev. 08.13.07
1 of 3

Related parts for LPQ113

LPQ113 Summary of contents

Page 1

... EN55022 Class B conducted VDE 0878 PT3 Class B conducted 0 50/60 Hz, 264 Vac input Safety ground leakage current Output Maximum power 80 W convection 110 W with 30 CFM forced air Adjustment range ± 5% min. on main 4th output on LPQ112 and LPQ113 Cross regulation ± output 1; ±3% on outputs 2, 3 & 4 Hold-up time load, 115 VAC nominal line Overload protection S hort circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection 6.7 VDC on main output. Latching type, recycle AC to reset ...

Page 2

... Embedded Power for Business-Critical Continuity Pin Assignments Connector LPQ112 LPQ113 SK1-1 GND GND SK1-3 Neutral Neutral SK1-5 Line Line SK2 SK2 SK2 SK2-4 Common Common SK2-5 Common Common ...

Page 3

Mechanical Drawing -B Bracket 4.28" (108.6) 2.5" (63.5) 6.4" (162.6) 2.2" (56) 0.86" (21.8) 0.25" (6.35) 4.0" (101.6) 3.5" (88. 6.5" 0.25" (165.1) (6.35) 1.80" (45.7) 0.12" (3) #6-32 PEM 6 places 7.3" (185.5) 5.9" (150.0) SK 202 M2 (POK) ...