IC MAX 7000 CPLD 64 100-TQFP

EPM7064STI100-7N

Manufacturer Part NumberEPM7064STI100-7N
DescriptionIC MAX 7000 CPLD 64 100-TQFP
ManufacturerAltera
SeriesMAX® 7000
EPM7064STI100-7N datasheet
 


Specifications of EPM7064STI100-7N

Programmable TypeIn System ProgrammableDelay Time Tpd(1) Max7.5ns
Voltage Supply - Internal4.5 V ~ 5.5 VNumber Of Logic Elements/blocks4
Number Of Macrocells64Number Of Gates1250
Number Of I /o68Operating Temperature-40°C ~ 85°C
Mounting TypeSurface MountPackage / Case100-TQFP, 100-VQFP
Voltage5VMemory TypeEEPROM
Number Of Logic Elements/cells4Lead Free Status / RoHS StatusLead free / RoHS Compliant
Features-Other names544-2315
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Page 21
22
Page 22
23
Page 23
24
Page 24
25
Page 25
26
Page 26
27
Page 27
28
Page 28
29
Page 29
30
Page 30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
Page 26/66

Download datasheet (2Mb)Embed
PrevNext
MAX 7000 Programmable Logic Device Family Data Sheet
Operating
Tables 13
ratings, recommended operating conditions, operating conditions, and
Conditions
capacitance for 5.0-V MAX 7000 devices.
Table 13. MAX 7000 5.0-V Device Absolute Maximum Ratings
Symbol
Parameter
V
Supply voltage
CC
V
DC input voltage
I
I
DC output current, per pin
OUT
T
Storage temperature
STG
T
Ambient temperature
AMB
T
Junction temperature
J
Table 14. MAX 7000 5.0-V Device Recommended Operating Conditions
Symbol
Parameter
V
Supply voltage for internal logic and
CCINT
input buffers
V
Supply voltage for output drivers,
CCIO
5.0-V operation
Supply voltage for output drivers,
3.3-V operation
V
Supply voltage during ISP
CCISP
V
Input voltage
I
V
Output voltage
O
T
Ambient temperature
A
T
Junction temperature
J
t
Input rise time
R
t
Input fall time
F
26
through
18
provide information about absolute maximum
Note (1)
Conditions
With respect to ground
(2)
No bias
Under bias
Ceramic packages, under bias
PQFP and RQFP packages, under bias
Conditions
(3), (4),
(5)
(3),
(4)
(3), (4),
(6)
(7)
For commercial use
For industrial use
For commercial use
For industrial use
Min
Max
Unit
–2.0
7.0
V
–2.0
7.0
V
–25
25
mA
–65
150
° C
–65
135
° C
150
° C
135
° C
Min
Max
Unit
4.75
5.25
V
(4.50)
(5.50)
4.75
5.25
V
(4.50)
(5.50)
3.00
3.60
V
(3.00)
(3.60)
4.75
5.25
V
–0.5
(8)
V
+ 0.5
V
CCINT
0
V
V
CCIO
0
70
° C
–40
85
° C
0
90
° C
–40
105
° C
40
ns
40
ns
Altera Corporation