XC3S250E-4TQG144C Xilinx Inc, XC3S250E-4TQG144C Datasheet - Page 10

IC SPARTAN-3E FPGA 250K 144TQFP

XC3S250E-4TQG144C

Manufacturer Part Number
XC3S250E-4TQG144C
Description
IC SPARTAN-3E FPGA 250K 144TQFP
Manufacturer
Xilinx Inc
Series
Spartan™-3Er
Datasheet

Specifications of XC3S250E-4TQG144C

Number Of Logic Elements/cells
5508
Number Of Labs/clbs
612
Total Ram Bits
221184
Number Of I /o
108
Number Of Gates
250000
Voltage - Supply
1.14 V ~ 1.26 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
144-LQFP
For Use With
813-1009 - MODULE USB-TO-FPGA TOOL W/MANUAL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
122-1524

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX
Quantity:
2 000
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX
Quantity:
2 400
Part Number:
XC3S250E-4TQG144C
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX
Quantity:
5 000
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX
Quantity:
5 000
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX
0
Part Number:
XC3S250E-4TQG144C
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Part Number:
XC3S250E-4TQG144CS1
Manufacturer:
XILINX
0
Part Number:
XC3S250E-4TQG144CS1
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Functional Description
Introduction
As described in
FPGA architecture consists of five fundamental functional
elements:
The following sections provide detailed information on each
of these functions. In addition, this section also describes
the following functions:
Input/Output Blocks (IOBs)
For additional information, refer to the “Using I/O
Resources” chapter in UG331.
IOB Overview
The Input/Output Block (IOB) provides a programmable,
unidirectional or bidirectional interface between a package
pin and the FPGA’s internal logic. The IOB is similar to that
of the Spartan-3 family with the following differences:
The unidirectional input-only block has a subset of the full
IOB capabilities. Thus there are no connections or logic for
10
Input/Output Blocks (IOBs)
Configurable Logic Block (CLB) and Slice
Resources
Block RAM
Dedicated Multipliers
Digital Clock Managers (DCMs)
Clocking Infrastructure
Interconnect
Configuration
Powering Spartan-3E FPGAs
Input-only blocks are added
Programmable input delays are added to all blocks
DDR flip-flops can be shared between adjacent IOBs
Architectural
Overview, the Spartan™-3E
www.xilinx.com
an output path. The following paragraphs assume that any
reference to output functionality does not apply to the
input-only blocks. The number of input-only blocks varies
with device size, but is never more than 25% of the total IOB
count.
Figure 5, page 11
nal structure. There are three main signal paths within the
IOB: the output path, input path, and 3-state path. Each
path has its own pair of storage elements that can act as
either registers or latches. For more information, see
age Element
as follows:
The input path carries data from the pad, which is
bonded to a package pin, through an optional
programmable delay element directly to the I line. After
the delay element, there are alternate routes through a
pair of storage elements to the IQ1 and IQ2 lines. The
IOB outputs I, IQ1, and IQ2 lead to the FPGA’s internal
logic. The delay element can be set to ensure a hold
time of zero (see
The output path, starting with the O1 and O2 lines,
carries data from the FPGA’s internal logic through a
multiplexer and then a three-state driver to the IOB
pad. In addition to this direct path, the multiplexer
provides the option to insert a pair of storage elements.
The 3-state path determines when the output driver is
high impedance. The T1 and T2 lines carry data from
the FPGA’s internal logic through a multiplexer to the
output driver. In addition to this direct path, the
multiplexer provides the option to insert a pair of
storage elements.
All signal paths entering the IOB, including those
associated with the storage elements, have an inverter
option. Any inverter placed on these paths is
automatically absorbed into the IOB.
Functions. The three main signal paths are
is a simplified diagram of the IOB’s inter-
Input Delay
DS312-2 (v3.8) August 26, 2009
Functions).
Product Specification
Stor-
R