EZ80L92AZ050SG Zilog, EZ80L92AZ050SG Datasheet - Page 129

IC WEBSERVER 50MHZ 100LQFP

EZ80L92AZ050SG

Manufacturer Part Number
EZ80L92AZ050SG
Description
IC WEBSERVER 50MHZ 100LQFP
Manufacturer
Zilog
Datasheet

Specifications of EZ80L92AZ050SG

Processor Type
eZ80
Features
High Speed, Single-Cycle Instruction-Fetch
Speed
50MHz
Voltage
3.3V
Mounting Type
Surface Mount
Package / Case
100-LQFP
Processor Series
EZ80L92x
Core
eZ80
Data Bus Width
8 bit
Program Memory Size
64 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
24
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80L920210ZCO
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-3878
EZ80L92AZ050SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80L92AZ050SG
Manufacturer:
Everlight
Quantity:
12 000
Part Number:
EZ80L92AZ050SG
Manufacturer:
Zilog
Quantity:
10 000
Infrared Encoder/Decoder
PS013014-0107
System
Clock
Functional Description
Interrupt
Signal
The eZ80L92 MCU contains a UART to infrared encoder/decoder (endec). The infrared
encoder/decoder is integrated with the on-chip UART0 to allow easy communication
between the eZ80 CPU and IrDA Physical Layer Specification Version 1.3 compliant
infrared transceivers as illustrated in
reliable, high-speed, low-cost, and point-to-point communication between PCs, PDAs,
mobile telephones, printers, and other infrared enabled devices.
When the infrared encoder/decoder is enabled, the transmit data from the on-chip UART
is encoded as digital signals in accordance with the IrDA standard and output to the
infrared transceiver. Likewise, data received from the infrared transceiver is decoded by
the infrared encoder/decoder and passed to the UART. Communication is half-duplex
meaning that simultaneous data transmission and reception is not allowed.
The baud rate is set by the UART Baud Rate Generator and supports IrDA standard baud
rates from 9600 bps to 115.2 Kbps. Higher baud rates are possible, but do not meet IrDA
specifications. The UART must be enabled to use the infrared encoder/decoder.
Address
UART0
I/O
Figure 24. Infrared System Block Diagram
Data
To eZ80 CPU
Baud Rate
eZ80L92
Clock
RxD
TxD
Encoder/Decoder
Figure
Infrared
Address
I/O
24. Infrared communication provides secure,
Data
IR_RxD
IR_TxD
Product Specification
Infrared Encoder/Decoder
RxD
TxD
Transceiver
Infrared
123