EZ80L92AZ050SG Zilog, EZ80L92AZ050SG Datasheet - Page 89

IC WEBSERVER 50MHZ 100LQFP

EZ80L92AZ050SG

Manufacturer Part Number
EZ80L92AZ050SG
Description
IC WEBSERVER 50MHZ 100LQFP
Manufacturer
Zilog
Datasheet

Specifications of EZ80L92AZ050SG

Processor Type
eZ80
Features
High Speed, Single-Cycle Instruction-Fetch
Speed
50MHz
Voltage
3.3V
Mounting Type
Surface Mount
Package / Case
100-LQFP
Processor Series
EZ80L92x
Core
eZ80
Data Bus Width
8 bit
Program Memory Size
64 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
24
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80L920210ZCO
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-3878
EZ80L92AZ050SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80L92AZ050SG
Manufacturer:
Everlight
Quantity:
12 000
Part Number:
EZ80L92AZ050SG
Manufacturer:
Zilog
Quantity:
10 000
PS013014-0107
Note:
Timer Data Registers—Low Byte
This Read-Only register returns the Low byte of the current count value of the selected
timer. The Timer Data Register—Low Byte, detailed in
timer is in operation. Reading the current count value does not affect timer operation. To
read the 16-bit data of the current count value, {TMRx_DR_H[7:0], TMRx_DR_L[7:0]},
first read the Timer Data Register—Low Byte and then read the Timer Data Register—
High Byte. The Timer Data Register—High Byte value is latched when a Read of the
Timer Data Register—Low Byte occurs.
The Timer Data registers and Timer Reload registers share the same address space.
6
IRQ_EN
5
4
PRT_MODE
[3:2]
CLK_DIV
1
RST_EN
0
PRT_EN
00
01
10
11
0
1
0
0
1
0
1
0
1
Timer interrupt requests are disabled.
Timer interrupt requests are enabled.
Reserved.
The timer operates in SINGLE PASS mode. PRT_EN (bit 0) is
reset to 0, and counting stops when the end-of-count value is
reached.
The timer operates in CONTINUOUS mode. The timer reload
value is written to the counter when the end-of-count value is
reached.
Clock ÷ 4 is the timer input source.
Clock ÷ 16 is the timer input source.
Clock ÷ 64 is the timer input source.
Clock ÷ 256 is the timer input source.
The reload and restart function is disabled.
The reload and restart function is enabled. When a 1 is written to
RST_EN, the values in the reload registers are loaded into the
downcounter and the timer restarts.
The programmable reload timer is disabled.
The programmable reload timer is enabled.
Table
33, can be read while the
Programmable Reload Timers
Product Specification
eZ80L92 MCU
83

Related parts for EZ80L92AZ050SG