D4B3516N Omron, D4B3516N Datasheet
D4B3516N
Specifications of D4B3516N
Related parts for D4B3516N
D4B3516N Summary of contents
Page 1
... Safety of lever settings ensured mechanism engages a gear between the operating position indicator plate and the lever Conforms to EN (TÜV) standards H corresponding to the CE marking 3-conduit switches are available for easy H wiring Conforms to these standards and H EC Directives: Machinery Directive Low Voltage Directive ...
Page 2
... The snap-action models with adjustable roller levers or adjustable rod levers are not approved under the Forced Opening Certificate (TÜV) of the EN standard. 2. The wobble lever models are ordinary limit switches and are not approved under EN, GS, and SUVA’s Forced Opening Certificate. ...
Page 3
... Certificate (TÜV) of the EN standard. 2. The D4B- Limit Switch conforming to European standards, and PG13.5 is commonly used in Europe. 3. The wobble lever models are ordinary limit switches and are not approved under EN, GS, and SUVA’s Forced Opening Certificate. J LEVERS (FOR SIDE ROTARY SWITCHES) ...
Page 4
... The life expectancy is for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further conditions, consult your OMRON sales representative. 3. The values in this table are for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further condi- tions, consult your OMRON sales representative. Current Make ...
Page 5
... FP max. --- OP --- Note: 1. The operating characteristics of these Switches were measured with the roller lever set at 31.5 mm. 2. The operating characteristics of these Switches were measured with the rod lever set at 140 mm. 3. Only for slow-action models. 4. Only for snap-action models. Engineering Data ...
Page 6
Nomenclature Head With roller lever models, the direction of the switch head can be varied to any of the four directions by loosening the roller lever switch screws at the four corners of the head. Operating Position Mark (arrow) The ...
Page 7
... When placing your order, specify the conduit type by adding a code (see below) to the first blank box in the model number of the selected switch. (For more ordering information, refer to the Model Number Legend, found in the Ordering Information of this data sheet.) Key for Part No. Code: Conduit type for standard switches 1: PG 13.5 (European 1/2 (Japanese) 3: 1/2-14NPT (North American) ...
Page 8
Adjustable Roller Lever Switch, Rubber Roller D4B-3113N, D4B-3513N, D4B-3A13N R41-R89 (R1.61-R3.50) (2.36) (1.18) Adjustable Roller Lever D4B-jj16N Adjustable Rod Lever D4B-jj17N 68.3 ±1 (2.96) Two, 5.3 dia. (0.21) mounting holes (0.13) 71±1 64 dia. ...
Page 9
D4B-N Top Plunger D4B-jj70N 60±0.2 Top Roller Plunger D4B-jj71N 60±0.2 Coil Spring D4B-jj81N 18.2 dia. 203.5±1.2 29.1 60±0.2 8 Plastic Rod D4B-jj87N 61.5 18.2 dia. 203.5±1.2 29.1 60±0.2 16 Four, M3.5 x 24.5 PT 9.2 dia. head clamping screws Stainless ...
Page 10
... Switches Roller Lever D4B-jj11N Adjustable Roller Lever Switch, Rubber Roller D4B-7113N, D4B-7513N, D4B-7A13N R41-R89 (R1.61-R3.50) Six, 5.3 dia. (0.21) mounting holes (1.06) Adjustable Roller Lever D4B-jj16N 17.5 dia. x 6.6 resin roller Allen-head bolt Operating position indicator (see note Six, 5.3-dia. ...
Page 11
D4B-N Adjustable Rod Lever D4B-jj17N Top Plunger D4B-jj70N Top Roller Plunger D4B-jj71N 3 dia. x 160 stainless steel rod 145 max. Operating position indicator (see note Allen-head bolts Six, 5.3-dia. mounting holes Four, M3.5 ...
Page 12
Coil Spring D4B-jj81N Plastic Rod D4B-jj87N 201.9±1.2 Stainless steel coil spring The Switch can be actuated to all directions except to the axis center 18.2 dia. Seal cap Four, M3 head mounting screws Six, 5.3-dia. ...
Page 13
D4B-N J ROLLER LEVERS D4B-0001N 16.8 11.7 17.5 dia. x 6.8 resin roller 31.5 M5 hexagon clamping 7.3 dia. screws 15 11.5 D4B-0003N 50 dia. rubber roller 30 dia. R41 to 78.5 adjustable hexagon clamping screws D4B-0005N ...
Page 14
... CW, CCW or Two-way Operation The head of Side Rotary Switches can be converted in seconds to CW, CCW, or two-way operation. The conversion procedure follows. Operating position Procedure mark (arrow) 1. Remove the head by loosening the four screws that secure it. 2. Turn over the head to set the desired operation (CW, CCW, or both). The desired operation can be selected by setting the mode selector knob shown in the figure. This knob is factory set to the “ ...
Page 15
D4B-N J CORRECT USE Operating Environment The D4B-jN is for indoor use. The D4B-jN may malfunction if the D4B-jN is used outdoors. Be sure to use a model with a lever-type actuator for outdoor use instead. Do not use the ...
Page 16
... IP67. The Pg13.5 connector must be Nippon Flex’s ABS-08Pg13.5 or ABS-12 Pg13.5. Use OMRON’s SC-series connector which is suited to the cable in diameter. Properly attach the provided conduit cap to the unused conduit opening and securely tighten the cap screw within the specified torque when wiring the D4B-jN ...