Board Mount Pressure Sensors 0 to 100psid BUTTON Differ Gage 1.5mA

SCC100D

Manufacturer Part Number
SCC100D
Description
Board Mount Pressure Sensors 0 to 100psid BUTTON Differ Gage 1.5mA
Manufacturer
Honeywell
Type
Differential/Gager
Datasheet

Specifications of SCC100D

Operating Pressure
0 psi to 100 psi
Pressure Type
Gauge, Differential
Mounting Style
Through Hole
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Supply Current
1.5 mA
Pressure Range
0 to 100Psi
Overload Pressure (max)
150Psi
Mounting
Through Hole
Pin Count
4
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Datasheet -- SCC100D
file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (1 of 5)13/03/2005 05:31:37 ã
Representative
photograph, actual
product appearance
may vary.
Due to regional
agency approval
requirements, some
products may not be
available in your area.
Please contact your
regional Honeywell
office regarding your
product of choice.
SCC100D
Pressure Sensors: Measurement Type: Differential, Gage; 0
psid to 100 psid Operating Pressure, Constant Current,
"Button" package - No Port
Features
Typical Applications
Description
The SCC Series sensors offer an extremely low cost sensor element
with a temperature stable output when driven with a constant
current source. These integrated circuit sensors were designed for
extremely cost sensitive applications where precise accuracy over a
wide temperature range is not required. This series is intended for
use with non-corrosive, non-ionic working fluids such as air, and dry
gases.
Absolute devices have an internal vacuum reference and an output
voltage proportional to applied pressure. The differential devices
allow application of pressure to either side of the diaphragm and
devices are thereby available to measure both differential and gage
pressures.
This product is packaged either in standard low cost chip carrier
“button” package or a DIP package. Both packages are designed for
applications where the sensing element is to be integral to the OEM
Low Cost Sensor Element
Internal Temperature Compensation
Differential or Gage Pressures
Pneumatic Controls
Automotive Diagnostics
Medical Equipment
Dental Equipment
Environmental Controls

Related parts for SCC100D

SCC100D Summary of contents

Page 1

... This product is packaged either in standard low cost chip carrier “button” package or a DIP package. Both packages are designed for applications where the sensing element integral to the OEM file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (1 of 5)13/03/2005 05:31:37 ã ...

Page 2

... Zero Pressure Offset Accuracy (% Best Fit Straight Line) Input Resistance Output Resistance Operating Temperature Range Compensated Temperature Range Storage Temperature Range Media Compatibility file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (2 of 5)13/03/2005 05:31:37 ã Product Specifications Gage, Differential Unamplified 0 psid to 100 psid 150 psi 1.5 mA max. Yes No ...

Page 3

... Datasheet -- SCC100D UNSPSC Code UNSPSC Commodity Availability Series Name SCC100D Pressure Sensors: Measurement Type: Differential, Gage; 0 psid to 100 psid Operating Pressure, Constant Current, "Button" package - No Port file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (3 of 5)13/03/2005 05:31:37 ã 411121 411121 Transducers Global SCC Series ...

Page 4

... Pressure, Constant Current, "Button" package - No Port PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (4 of 5)13/03/2005 05:31:37 ã ...

Page 5

... DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. © Copyright Honeywell Inc.1998-2004 All rights reserved. file:///C|/Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20SCC100D.htm (5 of 5)13/03/2005 05:31:37 ã ...