PKV3325PI Ericsson Power Modules, PKV3325PI Datasheet

DC/DC Converters & Regulators Iso+/-15 Vdc Input 9-36V 3W

PKV3325PI

Manufacturer Part Number
PKV3325PI
Description
DC/DC Converters & Regulators Iso+/-15 Vdc Input 9-36V 3W
Manufacturer
Ericsson Power Modules
Series
PKVr
Datasheet

Specifications of PKV3325PI

Product
Isolated
Output Power
2 W
Input Voltage Range
9 V to 36 V
Number Of Outputs
2
Output Voltage (channel 1)
15 V
Output Current (channel 1)
0.1 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
0.1 A
Isolation Voltage
1.5 KV
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKV3325PI
Manufacturer:
ERICSSON
Quantity:
120
Part Number:
PKV3325PI
Manufacturer:
ERICSSON
Quantity:
38
Part Number:
PKV3325PI
Manufacturer:
INTERSIL
Quantity:
550
Key Features
• Industry standard DIL24
• Wide input voltage range,
• High efficiency 74–83% typical
• Low idling power
• Full output power up to +75 °C ambi-
• Input/Output isolation 1,500 Vdc
• MTBF > 650,000 hours at +25 °C
• Basic insulation according to
The PKV series of DC/DC power modules is intended for
general use in 12/24 V and 48/60V DC systems. Designed
with MOSFET transistors and 200 kHz switching fre-
quency, they are characterized by high efficiency over a
wide load range, very low quiescent power and an excel-
lent line and load regulation.
The DC/DC power modules are encapsulated in an ep-
oxy filled plastic box. The flammability ratings of the en-
Safety Approvals
E
9–36 V, 18–72 V
ent temperature
ambient
UL 60950-1
capsulating materials are in conformance with UL 94V-0
and have an adequate thermal conductivity. The materi-
als withstand all normal PBA cleaning methods. Ericsson
Power Modules is an ISO 9001/14001 certified supplier.
Design for Environment
Meets requirements in high-temperature
lead-free soldering processes.
Input 9-36 and 18-72 Vdc
PKV 3000 I – PKV 5000 I
Output up to 0.5A/3W
DC/DC converter
Datasheet

Related parts for PKV3325PI

PKV3325PI Summary of contents

Page 1

Key Features • Industry standard DIL24 • Wide input voltage range, 9–36 V, 18–72 V • High efficiency 74–83% typical • Low idling power • Full output power up to +75 °C ambi- ent temperature • Input/Output isolation 1,500 Vdc • MTBF > 650,000 hours at +25 °C ambient • Basic insulation according to UL 60950-1 Safety Approvals The PKV series of DC/DC power modules is intended for general use ...

Page 2

... ISO Vdc for 60 seconds. Leakage current is max Unit less than 1µA at nominal input voltage. pF The flammability rating for all construction parts of the DC/DC kHz converter meets UL 94V-0. EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 max be used I ...

Page 3

... Weight: Material: Copper Maximum 15 g Plating: 3 µm Tin over 1.5 µm Ni (0.53 oz). Case: Non conductive plastic, UL 94V-0. EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 (0.120 - 0.140) Function Dual output Negative input Negative input Output return Not connected Negative output ...

Page 4

... O I Output 1 typ min max 3.20 3.40 6.6 16.5 6.6 33 300 +100 –100 ±0.02 0.5 800 1300 0.5 1.65 0.50 1.62 0. min typ max 66 73 0.61 0.85 EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit μ %/° p-p dB Unit % W ...

Page 5

... At V out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1…1.0 × max O and long term drift max O =0.1…1.0 × I ...

Page 6

... Conditions max max O I Output 1 typ min max 11.76 12. 120 300 +150 –150 ± 0.02 1.2 800 1300 0.25 3 0.25 0.81 0. min typ max 76 82 0.66 0.95 EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit μ %/° p-p dB Unit % W ...

Page 7

... At V out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1…1.0 × max O and long term drift max O I =0.1…1.0 × I ...

Page 8

... EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit max –5 μ ±0.02 %/°C ms 1300 p-p dB Unit max % 0 ...

Page 9

... At V ≤ 80% of nominal the power module goes into hick up mode. out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1 …1.0 × max O and long term drift max O I =0.1 …1.0 × I ...

Page 10

... EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit max –15 150 mV μ ±0.02 %/°C ms 1300 p-p dB Unit ...

Page 11

... At V out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1 …1.0 × max O and long term drift max O =0.1 …1.0 × I ...

Page 12

... Power derating Conditions max max O I Output 1 min typ max 4.90 5. 300 +100 –100 ±0.02 0.5 900 1300 0.5 2.5 0.5 1.62 0. min typ max 75 82 0.55 0.84 EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit μ %/° p-p dB Unit % W ...

Page 13

... At V out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1…1.0 × max O and long term drift max O =0.1…1.0 × I ...

Page 14

... Power derating Conditions max max O I Output 1 typ min max 14.7 15 150 300 +200 –200 ±0.02 1.2 900 1300 0.2 3 0.20 0.65 0. min typ max 76 82 0.66 0.95 EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit μ %/° p-p dB Unit % W ...

Page 15

... At V out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions I =0.1…1.0 × max O and long term drift max O =0.1…1.0 × I ...

Page 16

... EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Unit max –12. 120 mV μ ±0.02 %/°C ms 1300 ms 0.125 A W 0.400 p-p dB ...

Page 17

... At V ≤ 80% of nominal the power module goes into hick up mode. out Miscellaneous Efficiency (typ) Characteristics η Efficiency P Power dissipation d EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Conditions =0.1…1.0 × max O and long term drift max O I =0.1…1.0 × I ...

Page 18

... B. Fig. 1 shows an example of filter and the results for this filter is shown below. Conducted noise PKV 3211 without filter PKV 5211 without filter 1 PKV 3211 with filter PKV 5211 with filter EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Fig. 1 ...

Page 19

... Modules guarantee stable operation with a verified ESR value of >10W across the output connections. For further information please contact your local Ericsson Power Modules representative. EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 Delivery Package Information ∙ The PKV series DC/DC converters are delivered in tubes with a lenght of 384 mm (15 ...

Page 20

... Ericsson Power Modules does not make any other war- ranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applica- tions, where malfunctions of product can cause injury to a person’s health or life). 0 EN/LZT 146 37 R3A © Ericsson Power Modules AB, March 2007 ...

Page 21

... No license is granted by implication or otherwise under any patent or patent rights of Ericsson Power Modules. These products are sold only according to Ericsson Power Modules’ general conditions of sale, unless otherwise confirmed in writing. Specifications subject to change without notice. ...

Related keywords