SLC100-9 Murata Power Solutions Inc, SLC100-9 Datasheet
SLC100-9
Specifications of SLC100-9
Related parts for SLC100-9
SLC100-9 Summary of contents
Page 1
... SLC100 40 Amp Single Output Quarter Brick DC/DC Converter The SLC100 Series Amp single output, low-profile DC-DC converter in an industry standard package of 2.28” x 1.45” x 0.40”. The SLC100 uses unique proprietary technologies to deliver ultra- high efficiencies and excellent thermal performance ...
Page 2
ABSOLUTE MAXIMUM RATINGS, ALL MODELS PARAMETER Input Voltage-Operating Input Voltage-Operating Operating Ambient Temperature Storage Temperature Output Short Circuit Duration Lead Temperature (Soldering, 10 sec max) COMMON ELECTRICAL SPECIFICATIONS, ALL MODELS Specifications are +25°C, Airflow = 300LFM (1.5m/s) ...
Page 3
... MECHANICAL (THROUGH HOLE) MECHANICAL (SMT) SLC100 Rev B 5/2004 PIN FUNCTIONS 1 +Vin 2 Remote On/Off 3 -Vin 4 -Vout 5 - Sense 6 Trim 7 + Sense 8 +Vout NOTES: General Tolerance; .015 ± Pin Locations/Diameters: .005 ± Dimensions are in inches [Millimeters] Pin material: Copper Pin Finish: Matte Tin over Nickel Converter weight: [30 ...
Page 4
... SLC100 - 17 5.0 SMD SLC100 - 18 12.0 SMD ORDERING INFORMATION LOGIC MODEL NUMBER Positive SLC100 - 19 Positive SLC100 - 20 Positive SLC100 - 21 Positive SLC100 - 22 Positive SLC100 - 23 SLC100 - 24 Positive Positive SLC100 - 25 Positive SLC100 - 26 Positive SCL100 - 27 Positive SLC100 - 28 Positive SLC100 - 29 Positive SLC100 - 30 Positive SLC100 - 31 Positive SLC100 - 32 Positive SLC100 - 33 ...
Page 5
... Remote Sense The remote sense feature of the SLC100 can be used to compensate for voltage drops in the output power lines by sensing output voltage directly at the point of load. To enable this feature, connect the +Sense and –Sense pins to the +Vout and –Vout pins, respectively, at the point in the circuit where the tightest regulation is required (Figure 1) ...
Page 6
... Input Under-Voltage Shutdown The nominal input voltage for the SLC100 is 48Vdc. Once turned on reducing the input voltage to 32.5 Vdc nominal will shut down the device input voltage less than 32 ...
Page 7
... Thermal Derating Maximum output current vs. ambient temperature at various airflow rates has been determined for each model of the SLC100. Each model was analyzed over an ambient temperature range flows up to 600LFM. Temperature limits for thermal derating curves were TBD C for semiconductor junction temperature and TBD C for board temperature ...
Page 8
... SLC100 1.2VOUT ELECTRICAL SPECIFICATIONS Specifications are +25°C, Airflow = 300LFM (1.5m/s) at nominal input voltage unless otherwise specified. A PARAMETER INPUT Maximum Input Current Inrush Charge Reflected Ripple Current Input Voltage Ripple Rejection No Load Input Current Disabled Input Current Quiescent Input Current ...
Page 9
... SLC100 1.5VOUT ELECTRICAL SPECIFICATIONS Specifications are +25°C, Airflow = 300LFM (1.5m/s) at nominal input voltage unless otherwise specified. A PARAMETER INPUT Maximum Input Current Inrush Charge Reflected Ripple Current Input Voltage Ripple Rejection No Load Input Current Disabled Input Current Quiescent Input Current ...