PKM4113PI Ericsson Power Modules, PKM4113PI Datasheet

no-image

PKM4113PI

Manufacturer Part Number
PKM4113PI
Description
DC/DC Converters & Regulators 12 Vdc 10.5A Iso Input 36-75V 126W
Manufacturer
Ericsson Power Modules
Series
PKMr
Datasheet

Specifications of PKM4113PI

Product
Isolated
Output Power
126 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
10.5 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKM4113PI
Manufacturer:
TE
Quantity:
201
Part Number:
PKM4113PI
Manufacturer:
ERICSSON
Quantity:
38
Part Number:
PKM4113PI
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4113PILA
Manufacturer:
ERICSSON
Quantity:
530
Part Number:
PKM4113PILA
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4113PILA2
Manufacturer:
ERICSSON
Quantity:
134
Part Number:
PKM4113PILA2
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKM4113PIP
Manufacturer:
VICOR
Quantity:
726
Part Number:
PKM4113PIP
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
E
Contents
General Information
Safety Specification
Absolute Maximum Ratings
1.5 V/20 A Electrical Specification
1.5 V/30 A Electrical Specification
1.8 V/20 A Electrical Specification
1.8 V/30 A Electrical Specification
1.8 V/35 A Electrical Specification
2.5 V/20 A Electrical Specification
2.5 V/30 A Electrical Specification
3.3 V/15 A Electrical Specification
3.3 V/20 A Electrical Specification
3.3 V/25 A Electrical Specification
5 V/15 A Electrical Specification
5 V/20 A Electrical Specification
12 V/10.5 A Electrical Specification
EMC Specification
Operating Information
Thermal Consideration
Connections
Mechanical Information
Soldering Information
Delivery Information
Product Qualification Specification
Prepared (also subject responsible if other)
Prepared (also subject responsible if other)
SEC/D Kevin Chen
SEC/D Kevin Chen
Approved
Approved
PKM 4000 PI series
DC/DC converters, Input 36-75 V, Output 35 A/126 W
Key Features
• Industry standard low profile Quarter-brick
• High efficiency, typ. 91 % at 2.5 Vout full load
• 1500 Vdc input to output isolation
• Meets isolation requirements equivalent to basic
General Characteristics
• Output over voltage protection
• Input under voltage protection
• Over temperature protection
• Soft start
• Output short-circuit protection
• Remote sense
• Remote control
• Output voltage adjust function
• Highly automated manufacturing ensures quality
• ISO 9001/14001 certified supplier
Product Program
57.93 x 36.80 x 12.7 mm (2.278 x 1.449 x 0.50 in.)
insulation according to IEC/EN/UL 60950
More than 1.55 million hours MTBF according to
Telcordia
PKM 4318 PIOA .................................. 5
PKM 4418A PIOA................................. 8
PKM 4318 PI ...................................... 11
PKM 4518A PI.................................... 14
PKM 4618A PI.................................... 17
PKM 4519 PI ...................................... 20
PKM 4719A PI.................................... 23
PKM 4510 PI ...................................... 26
PKM 4610 PI ...................................... 29
PKM 4810A PI.................................... 32
PKM 4711 PI ...................................... 35
PKM 4111 PI ...................................... 38
PKM 4113 PI ...................................... 41
............................................................. 2
............................................................. 3
............................................................. 4
........................................................... 44
........................................................... 45
........................................................... 47
........................................................... 47
........................................................... 48
........................................................... 49
........................................................... 49
........................................................... 50
Ordering No.
Checked
Checked
Ericsson Internal
Limited Internal
PRODUCT SPECIFICATION
TABLE OF CONTENTS
No.
No.
1/1301-BMR631
00152-EN/LZT146310
Date
Date
2006-11-3
2006-11-3
Safety Approvals
Technical Specifi cation
EN/LZT 146 310 R1B Nov 2006
© Ericsson Power Modules AB
Rev
Rev
PA1
B
Design for Environment
Meets requirements in high-
temperature lead-free soldering
processes.
Reference
Reference
1 (3)
1 (1)

Related parts for PKM4113PI

PKM4113PI Summary of contents

Page 1

... PKM 4111 PI ...................................... 38 PKM 4113 PI ...................................... 41 ........................................................... 44 ........................................................... 45 ........................................................... 47 ........................................................... 47 ........................................................... 48 ........................................................... 49 ........................................................... 49 ........................................................... 50 Technical Specifi cation Rev Reference Rev Reference EN/LZT 146 310 R1B Nov 2006 PA1 B © Ericsson Power Modules AB Design for Environment Meets requirements in high- temperature lead-free soldering processes. 1 (3) 1 (1) ...

Page 2

... Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’ ...

Page 3

... Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. ...

Page 4

... Positive logic option Negative logic option Primary Primary Driver Isolated Feedback Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB min typ -40 -40 -0.5 -0.5 -0.5 -0.5 Secondary Secondary Driver Control and Supervision ...

Page 5

... Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4318 PIOA min typ max 1 86.0 85.0 85.6 84.8 5.5 2.6 4 ...

Page 6

... 0.5 0.0 20 [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.0 0.5 1.0 1.5 2.0 Thermal resistance vs. airspeed measured at the converter. ...

Page 7

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4318 PIOA at: Top trace: output voltage (0.5 V/div.). I Bottom trace: input voltage (20 V/div.). Time scale: 5 ms/div.. Top trace: output voltage (100mV/div.). Time scale: 0.1 ms/div.. ...

Page 8

... Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4418A PIOA min typ max 1 88.7 88.0 89.6 88.2 6.1 2.6 4 ...

Page 9

... Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Current Limit Characteristics [ 0. Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4418A PIOA +25°C ref 0.5 1.0 1.5 2.0 2 utput voltage vs. load current at I > max ...

Page 10

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4418A PIOA at: Top trace: output voltage (0.5 V/div). I Bottom trace: input voltage (20 V/div). Time scale: (5 ms/div). Top trace: output voltage (200mV/div). Time scale: 0.2 ms/div. ...

Page 11

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4318 PI min typ max 1 87.0 86.6 87.3 87.0 5.6 2.6 4.6 ...

Page 12

... V 1. 0.50 0. [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 13

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4318 PI at: Top trace: output voltage (0.5 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (200mV/div). Time scale: 0.2 ms/div. ...

Page 14

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4518A PI min typ max 1 88.0 88.6 88.9 88.8 7.0 2.6 4.6 ...

Page 15

... 1. 1.00 0.50 0. [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 16

... ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4518A PI Place your graph here at: Top trace: output voltage (0.5 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Place your graph here Top trace: output voltage (100mV/div) ...

Page 17

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4618A PI min typ max 2 89.8 88.6 90.1 88.4 8.2 2.6 4.6 ...

Page 18

... Current Limit Characteristics [V] 2. 0.50 0. [A] O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.0 0.5 1.0 1.5 2.0 Thermal resistance vs. airspeed measured at the converter. ...

Page 19

... ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4618A PI Place your graph here at: Top trace: output voltage (0.5 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Place your graph here Top trace: output voltage (100mV/div) ...

Page 20

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4519 PI min typ max 1 88.8 89.5 89.3 89.6 5.9 2.6 4.6 ...

Page 21

... 0.70 0. [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 22

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4519 PI at: Top trace: output voltage (1 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (200mV/div). Time scale: 0.2 ms/div. ...

Page 23

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4719A PI min typ max 1 89.7 89.3 90.3 89.3 9.0 2.6 4.6 ...

Page 24

... V 2 1.4 0.7 0 [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.0 0.5 1.0 1.5 2.0 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 25

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4719A PI at: Top trace: output voltage (1 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 0.1 ms/div. Top trace: output voltage (100mV/div). Time scale: 0.1 ms/div. ...

Page 26

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4510 PI min typ max 1 90.4 90.3 90.8 90.4 5.3 2.6 4.6 ...

Page 27

... 2. 1.00 0. [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 28

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4510 PI PKM 4510 PI at: Top trace: output voltage (1 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (200mV/div). ...

Page 29

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4610 PI min typ max 1 90.1 88.2 90.8 88.3 8.9 2.6 4.6 ...

Page 30

... 2. 1.80 0.90 0.00 20 [A] Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. ...

Page 31

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4610 PI PKM 4510 PI at: Top trace: output voltage (1 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (200mV/div). ...

Page 32

... Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4810A PI min typ max 1.5 82.5 53 91.8 89.6 91.8 89.7 9.6 2 ...

Page 33

... 1.8 0.9 0 [A] O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 34

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4810A PI PKM 4510 PI at: Top trace: output voltage (1 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (200mV/div). ...

Page 35

... T = 25ºC, see Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4711 PI min typ max 1 90.7 91.5 91.8 91.4 7.0 2.6 4.6 ...

Page 36

... 3 2.0 1.0 0 Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules Dissipated power vs. load current and input voltage +25°C ref 0.5 1.0 1.5 2.0 2.5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 37

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4711 PI PKM 4510 PI at: Top trace: output voltage (2 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (100mV/div). ...

Page 38

... Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4111 PI min typ max 2.8 100 53 92.0 90.9 92.1 90.9 10.2 2 ...

Page 39

... Thermal consideration section. Current Limit Characteristics [V] 6 [A] O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules [A] = +25°C ref 0.5 1.0 1.5 2.0 2 utput voltage vs. load current at I > max (41) ...

Page 40

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4111 PI PKM 4510 PI at: Top trace: output voltage (2 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (100mV/div). ...

Page 41

... Note 2 ref max see Note +25° 0-100% of ref I max I O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4113 PI min typ max 2.8 126 53 92.6 92.2 93.2 92.3 10.8 2 ...

Page 42

... Thermal consideration section. Current Limit Characteristics [V] 16. 12. 8. 4.00 0. [A] O utput voltage vs. load current at I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules +25°C 0.5 1.0 1.5 2.0 2 > max ref 39 (41) 42 ...

Page 43

... V. ref I Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 C © Ericsson Power Modules AB PKM 4113 PI PKM 4113 PI at: Top trace: output voltage (5 V/div). I Bottom trace: input voltage (20 V/div). Time scale: 5 ms/div. Top trace: output voltage (100mV/div). ...

Page 44

... Output ripple and noise measured according to figure below. Filter components: See Design Note 022 for detailed information. Output ripple and noise test setup Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB 2 (6) 44 ...

Page 45

... To decrease the output voltage, the resistor should be connected between the V Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB ) adj pin and +Sense pin. The resistor value of the adj pin and —Sense pin. adj ...

Page 46

... Position Device P Baseplate 1 ). The O Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules Designation max value T 100º C ref TOP VIEW Airflow 4 (6) 46 ...

Page 47

... Pin Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB TOP VIEW Designation Function +In Positive Input RC Remote Control -In Negative Input -Out Negative Output -Sen Negative Remote Sense Vadj Output voltage adjust +Sen ...

Page 48

... Approved PKM 4000 PI series SEC/D (Linda zhong) DC/DC converters, Input 36-75 V, Output 35 A/126 W Mechanical information PRODUCT SPECIFICATION No. 4/1301-BMR 631 Checked Date (MICKAOV) 2006-1-26 Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB 1 (4) 48 ...

Page 49

... Bake ability The clamshells can not be baked 20 converters/clamshell clamshell capacity Box capacity 100 converters (5 full clamshells/box) PRODUCT SPECIFICATION No. 4/1301-BMR 631 Checked Date (MICKAOV) 2006-1-26 Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB 2 (4) 49 ...

Page 50

... Frequency Acceleration Duration in each direction Frequency Amplitude Acceleration No. of cycles Technical Specifi cation Rev Reference EN/LZT 146 310 R1B Nov 2006 B © Ericsson Power Modules AB -40 °C-+100 °C 0.5 h 300 -40 °C-+125 ° Minimum No +85 ° Maximum 1000 hours 1000 hours 125° ...

Related keywords