DC/DC Converters & Regulators CONV DC/DC 1W 4.5-18VIN +/-05VOUT

RSO-1205DZ/H3

Manufacturer Part Number
RSO-1205DZ/H3
Description
DC/DC Converters & Regulators CONV DC/DC 1W 4.5-18VIN +/-05VOUT
Manufacturer
Recom Power Inc
Series
Econoline RSOr
Type
-r
Datasheet

Specifications of RSO-1205DZ/H3

Product
Isolated
Output Power
1 W
Input Voltage Range
4.5 V to 18 V
Input Voltage (nominal)
9 V
Number Of Outputs
2
Output Voltage (channel 1)
- 5 V
Output Current (channel 1)
- 100 mA
Output Voltage (channel 2)
5 V
Output Current (channel 2)
100 mA
Output Voltage
+/- 5 V
Voltage - Input (min)
4.5V
Voltage - Input (max)
18V
Power (watts) - Manufacture Series
1W
Power (watts) - Max
1W
1st Output
5 VDC @ 100mA
2nd Output
-5 VDC @ 100mA
3rd Output
-
Voltage - Isolation
3kV (3000V)
Mounting Type
Through Hole
Package / Case
8-SIP Module (7 Leads)
Size / Dimension
0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm)
Operating Temperature
-40°C ~ 85°C
Efficiency
73 ~ 77%
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
www.recom-international.com
High-power-density, an industrial temperature range of -40°C to +85°C and extra features like Remote-On-Off-
control are just some of the characteristics of this converter, ideal for highly sophisticated industrial-designs. The RSO
series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which case it is also ideal for medical
applications which additionally require EN-60601-1 certification. The “Z” version features 4:1 input voltage range, while
the standard version offers 2:1 input voltage range and includes a low voltage input range down to 4.5V.
Description
Selection Guide
Features
Regulated
Converters
Part Number
SIP8
RSO-xx3.3S (H2/H3)
RSO-xx05S (H2/H3)
RSO-xx09S (H2/H3)
RSO-xx12S (H2/H3)
RSO-xx15S (H2/H3)
RSO-xx3.3D (H2/H3)
RSO-xx05D (H2/H3)
RSO-xx09D (H2/H3)
RSO-xx12D (H2/H3)
RSO-xx15D (H2/H3)
RSO-xx3.3SZ (H2/H3)
RSO-xx05SZ (H2/H3)
RSO-xx09SZ (H2/H3)
RSO-xx12SZ (H2/H3)
RSO-xx15SZ (H2/H3)
RSO-xx3.3DZ (H2/H3)
RSO-xx05DZ (H2/H3)
RSO-xx09DZ (H2/H3)
RSO-xx12DZ (H2/H3)
RSO-xx15DZ (H2/H3)
No suffix is standard isolation (1kVDC) e.g, RSO-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3
Voltage Range
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
18-36, 36-72
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
4.5-9, 9-18
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
(VDC)
Input
9-36
9-36
9-36
9-36
9-36
9-36
9-36
9-36
9-36
9-36
Rated Output Output Current Efficiency
2:1 and 4:1 Wide Input Voltage Ranges
1kVDC, 2kVD or 3kVDC Isolation
UL94V-0 Package Material
Certified for Medical Applications
Continuous Short Circuit Protection
Low Noise
No External Capacitor needed
Efficiency to 83 %
Voltage
(VDC)
±3.3
±3.3
±12
±15
±12
±15
3.3
3.3
12
15
±5
±9
12
15
±5
±9
5
9
5
9
±150
±100
±150
±100
(mA)
300
200
111
±56
±42
±34
300
200
111
±56
±42
±34
83
67
83
67
REV:1/2010
68-72
73-75
75-78
74-78
78-81
75-80
80-83
75-80
80-83
68-72
73-75
75-76
74-78
75-79
79-80
75-79
79-80
typ.
(%)
70
70
78
70
70
78
75
81
78
83
80
83
80
74
70
77
75
78
78
80
80
80
80
Capacitive
±1500µF
±1500µF
±470µF
±470µF
±330µF
±330µF
±470µF
±470µF
±330µF
±330µF
3300µF
1200µF
3300µF
1200µF
Load
680µF
680µF
680µF
680µF
680µF
680µF
Max
(1)
(RS0-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
2:1 Input
ECONOLINE
DC/DC-Converter
with 3 year Warranty
EN-60950-1 Certified
EN-60601-1 Certified
(Suffix H3)
1 Watt
SIP8 Isolated
Single
Output
RSO
Refer to Application Notes
2002/95/EC
RoHS
6/6
xx = 9-36Vin = 24
xx = 18-72Vin = 48
(RSO-SZ/DZ)
4:1 Input
&
Dual
E-81

Related parts for RSO-1205DZ/H3

RSO-1205DZ/H3 Summary of contents

Page 1

... High-power-density, an industrial temperature range of -40°C to +85°C and extra features like Remote-On-Off- control are just some of the characteristics of this converter, ideal for highly sophisticated industrial-designs. The RSO series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which case it is also ideal for medical applications which additionally require EN-60601-1 certification. The “ ...

Page 2

... Single/Dual 30pF max. >1GΩ min. Continuous -40°C to +85°C (see Graph) -55°C to +125°C 95 pcs per Tube using MIL-HDBK 217F 1685 x 10 using MIL-HDBK 217F 254 x 10 RSO-all types REV: 1/2010 RSO-S_D(Z) Series Derating-Graph (Ambient Temperature) 0% RSO-S_D RSO-SZ_DZ 4.7g 3 hours ...

Page 3

... Isolated Remote CTRL Circuit www.recom-international.com Recommended Footprint Details EN60950-1:2001 + A11:2004 Pin 5 (NC) Not connected internally Voltage to be applied via a limiting resistor with a recommended value of 1K for RSO-05xx; 3.3K for RSO-12xx; RSO-24xx and 10K for RSO-48xx. REV:1/2010 RSO-S_D(Z) Series Pin Connections Pin # Single Dual 1 – ...

Related keywords