MPT-65C Mean Well, MPT-65C Datasheet

Linear & Switching Power Supplies 65W 5V/5.5A 15V/2A -15V/0.5A

MPT-65C

Manufacturer Part Number
MPT-65C
Description
Linear & Switching Power Supplies 65W 5V/5.5A 15V/2A -15V/0.5A
Manufacturer
Mean Well
Datasheet

Specifications of MPT-65C

Product
Switching
Commercial/medical
Medical
Output Power Rating
28 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5.5 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
- 15 V
Output Current (channel 3)
0.5 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT POWER (max.)
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
EMI CONDUCTION & RADIATION
65W Triple Output Medical Type
Note.3
Note.2
MPT-65A
CH1
5V
5.5A
0.4 ~ 7A
60W
72W with 18CFM min. Forced air convection
60mVp-p
CH1:4.5 ~ 5.5V
800ms, 20ms/230VAC
80ms/230VAC
90 ~ 264VAC
47 ~ 440Hz
1.6A/115VAC
73 ~ 95W
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +55
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL2601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A
275.1Khrs min.
127*76*42mm (L*W*H)
0.27Kg; 54pcs/16.8Kg/1.35CUFT
74%
COLD START 20A/115VAC
<0.3mA / 264VAC
4.0%
1.0%
3.0%
0.04%/
rated output power
(0 ~ 50 ) on +5V output
(Refer to output load derating curve)
CH2
12V
2.5A
0.2 ~ 3.2A
120mVp-p
+10,-7%
2.0%
4.0%
I/P-FG:1.5KVAC
127 ~ 370VDC
MIL-HDBK-217F (25 )
1A/230VAC
12ms/115VAC at full load
800ms, 20ms/115VAC at full load
CH3
-5V
0.5A
0 ~ 0.7A
60mVp-p
5.0%
1.0%
1.0%
40A/230VAC
O/P-FG:0.5KVAC 1min.
MPT-65B
63.5W
CH1
5V
5.5A
0.4 ~ 7A
60mVp-p
74%
4.0%
1.0%
3.0%
+10,-7%
CH2
12V
2.5A
0.2 ~ 3.2A
160mVp-p
2.0%
4.0%
CH3
-12V
0.5A
0 ~ 0.7A
100mVp-p
5.0%
1.0%
1.0%
M P T- 6 5
MPT-65C
65W
CH1
5V
5.5A
0.4 ~ 7A
60mVp-p
74%
4.0%
1.0%
3.0%
File Name:MPT-65-SPEC 2011-03-31
+10,-7%
CH2
15V
2A
0.2 ~ 2.6A
180mVp-p
2.0%
4.0%
EN60601-1
IEC60601-1
s e r i e s
CH3
-15V
0.5A
0 ~ 0.7A
100mVp-p
5.0%
1.0%
1.0%