LCC250-12U-4P Unspecified, LCC250-12U-4P Datasheet

no-image

LCC250-12U-4P

Manufacturer Part Number
LCC250-12U-4P
Description
Linear & Switching Power Supplies 250W12V 20.8A UL+CSA 60950-1 / 60601-1
Manufacturer
Unspecified
Datasheet

Specifications of LCC250-12U-4P

Output Power Rating
250 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
20.8 A
Dimensions
177.6 mm L x 101.4 mm W x 27.9 mm H
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
LCC250
250 Watts
Convection/Conduction
Mounting
Total Power:
# of Outputs:
Output:
Compliance
Special Features
• 12 VDC / 250 W output power
• Wide Operating Temperature
• IP64 Rated
• Conducted Mounting or
• Differential Remote Sense
• Output Adjust
• Output On/Off (Positive or
• EMI Class B
• EN61000 Immunity
Safety
• UL+CSA 60950-1
• TUV (Suffix ‘E’) 60950-1
60601-1
• CB Scheme
• EN61347-2-13
Range suited for outdoor
application
Convection
Negative user selectable)
60601-1
250 W
Single
12, 24, 48 V
60950-1
Electrical Specifications
Input
Input Ra n ge:
Frequency:
Input Fusing:
Inrush Current:
Power Factor:
Harmonics:
Input Current:
Hold Up Time:
Efficiency:
Leakage Current:
90 - 264 Vac (Operating)
115/230 Vac (Nominal)
47 - 63 Hz
Internal fuse on both L and N lines
50 A
> 0.92 Full load
Meets IEN 61000-3-2 Class C
3.4 A @ 90 Vac full load
16 ms minimum at 115 Vac; 100% load
230 Vac; 100% load
12 V - 89% typical
24 V - 91% typical
< 275 µA at 230 Vac
Embedded Power for
Business-Critical Continuity
Rev. 05.25.11_110
LCC250 Series
1 of 6

Related parts for LCC250-12U-4P

LCC250-12U-4P Summary of contents

Page 1

... Frequency Input Fusing: Internal fuse on both L and N lines Inrush Current Power Factor: > 0.92 Full load Harmonics: Meets IEN 61000-3-2 Class C Input Current: 3 Vac full load Hold Up Time minimum at 115 Vac; 100% load 230 Vac; 100% load 89% typical Efficiency 91% typical Leakage Current: < 275 µA at 230 Vac Embedded Power for Business-Critical Continuity Rev. 05.25.11_110 LCC250 Series ...

Page 2

... Latching mode; Requires input AC recycle Auto-recovery; hiccup mode Suffix 4P (Conduction): -40 °C to +85 °C Baseplate Temperature Suffix 7P (Convection): -40 °C to +85 °C Ambient Temperature -40 ° °C 10% to 100% (Condensing & Non-Condensing) Operating: 13,000 feet Non-Operating: 50,000 feet IEC68-2-27 IEC 68-2-6 / IEC 721-3-2 IP64 Rated > 780,000 hours at 100% load; Low line; Telcordia SR-332 Embedded Power for Business-Critical Continuity Rev. 05.25.11_110 LCC250 Series ...

Page 3

... Ordering Information Adjustment Model Number Output Range LCC250-12U- +10% / -10% LCC250-12U-4PE 12 V +10% / -10% LCC250-12U- +10% / -10% LCC250-12U-7PE 12 V +10% / -10% LCC250-24U- +14.6 / -15% LCC250-24U-4PE 24 V +14.6 / -15% LCC250-24U- +14.6 / -15% LCC250-24U-7PE 24 V +14.6 / -15% 1. Output ripple measured at the end of the output cable terminated with 10 µF tantalum cap in parallel with 0.1 µF ceramic capacitor limit is achieved with 2X 820 µF/16 V external cap (e.g. PLG1C821MDO1 from Nichicon or equivalent). Otherwise, maximum limits are 1. ≥ ...

Page 4

... Business-Critical Continuity Rev. 05.25.11_110 LCC250-12U-7P (Convection 115 VAC IN 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) Current Derating at 115 Vac LCC250- 24U- 4P (Conduction) 90V 115V 230V 264V Baseplate Temperature (°C) Current Derating LCC250- 24U-7P (Convection) Vin = 230 Vac 40 ...

Page 5

... Mechanical Drawings 12V 27.9 ± 0.6 LCC250-12U-4P 37.6 ± 0.6 LCC250-12U-7P 24V L1 AC INPUT 27.9 ± 0.6 LCC250-xxU-4P 37.6 ± 0.6 LCC250-xxU-7P L1 POTTING TRIM LABEL 6-Ø 3.6 ± 0.10 AC INPUT 59. 119. 119. 139.7) 177.6 ± 0.6 0.30 SERIAL NO. BARCODE LABEL MODEL LABEL POTTING TRIM LABEL 6-Ø ...

Page 6

... Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2011 Emerson Electric Co. Rev. 05.25.11_110 LCC250 Series ...

Related keywords