HLG-150-36 Mean Well, HLG-150-36 Datasheet

Linear & Switching Power Supplies 151.2W 36V 4.2A 90-264VAC IP67 Rated

HLG-150-36

Manufacturer Part Number
HLG-150-36
Description
Linear & Switching Power Supplies 151.2W 36V 4.2A 90-264VAC IP67 Rated
Manufacturer
Mean Well
Datasheet

Specifications of HLG-150-36

Product
Switching
Commercial/medical
Commercial
Output Power Rating
151.2 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
36 V
Output Current (channel 1)
4.2 A
Mounting Style
Chassis
Dimensions
228 mm L x 68 mm W x 38.8 mm H
Open Frame/enclosed
Enclosed
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
OTHERS
NOTE
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT(
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
150W Single Output Switching Power Supply
Typ
.)
Note.5
Note.6
Note.3
Note.8
Note.4
Note.7
Note.2
Note.4
HLG-150-12
12V
6 ~12V
12.5A
150W
150mVp-p
10.8 ~ 13.5V
Can be adjusted by internal potential meter or through output cable
7.5 ~ 12.5A
2500ms, 80ms
16ms at full load
90 ~ 264VAC
47 ~ 63Hz
PF 0.95/230VAC
100
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
1.15Kg; 12pcs/14.8Kg/0.76CUFT
92%
1.7A / 115VAC
COLD START 75A/230VAC
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, EN61347-1, EN61347-2-13 independent
I/P-O/P:3.75KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
192.2Khrs min.
228*68*38.8mm (L*W*H)
2.5%
0.5%
2.0%
0.03%/
10
(0 ~ 50 )
(RTH2)
HLG-150-15
15V
7.5 ~ 15V
10A
150W
150mVp-p
6 ~ 10A
at full load
92.5%
18 ~ 21V
13.5 ~ 17V
2.0%
0.5%
1.5%
127 ~ 370VDC
MIL-HDBK-217F (25 )
230VAC / 115VAC
0.75A / 230VAC
I/P-FG:1.88KVAC
PF 0.98/115VAC at full load and rated output voltage
230VAC
HLG-150-20
20V
10 ~ 20V
7.5A
150W
150mVp-p
17 ~ 22V
4.5 ~ 7.5A
93%
23 ~ 27V
1.0%
0.5%
1.0%
/ 115VAC ; B type 2500ms, 200ms at 95% load
HLG-150-24
24V
12 ~ 24V
6.3A
151.2W
150mVp-p
22 ~ 27V
3.8 ~ 6.3A
O/P-FG:0.5KVAC
93.5%
28 ~ 34V
1.0%
0.5%
0.5%
IP65 or IP67
HLG-150-30
30V
15 ~ 30V
150W
200mVp-p
27 ~ 33V
3 ~ 5A
5A
93.5%
34 ~ 38V
1.0%
0.5%
0.5%
IP65 IP67
approved ; Design refer to UL60950-1, TUV EN60950-1
HLG-150-36
36V
18 ~ 36V
4.2A
151.2W
200mVp-p
33 ~ 40V
2.5 ~ 4.2A
93.5%
41 ~ 46V
1.0%
0.5%
0.5%
H L G - 1 5 0
PF 0.9 at 60 ~ 100% load
HLG-150-42
42V
21 ~ 42V
3.6A
151.2W
200mVp-p
38 ~ 46V
2.16 ~ 3.6A
230VAC / 115VAC
94%
47 ~ 53V
1.0%
0.5%
0.5%
HLG-150-48
48V
24 ~ 48V
3.2A
153.6W
200mVp-p
43 ~ 53V
1.92 ~ 3.2A
94%
54 ~ 60V
1.0%
0.5%
0.5%
s e r i e s
HLG-150-54
54V
27 ~ 54V
2.8A
151.2W
200mVp-p
49 ~ 58V
1.68 ~ 2.8A
59 ~ 65V
94%
1.0%
0.5%
0.5%

Related parts for HLG-150-36

HLG-150-36 Summary of contents

Page 1

... PF 0.98/115VAC at full load and rated output voltage 92.5% 93% 93.5% 93.5% 0.75A / 230VAC 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V (RTH2 IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1 I/P-FG:1.88KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( HLG-150-36 HLG-150-42 HLG-150-48 HLG-150-54 36V 42V 48V 54V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V 4.2A 3.6A 3.2A 2.8A 151.2W 151.2W 153.6W 151 ...

Page 2

... IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter. (Can access by removing the rubber stopper on the case.) 228 12 204 9.6 228 204 12 9 Case No.994D Unit:mm 300 20 SJTW 14AWG 2C 4.2 4PL Vo Io ADJ. ADJ. 300 20 SJTW 14AWG 2C 4.2 4PL File Name:HLG-150-SPEC 2011-01- -V(Black) +V(Red) -V(Black) +V(Red) ...

Page 3

... RECTIFIERS & FILTER O.L.P. DETECTION CIRCUIT O.V.P. 100 125 135 145 155 165 175 180 200 INPUT VOLTAGE (V) 60Hz File Name:HLG-150-SPEC 2011-01- DIM+(Blue) DIM-(White) -V(Black) +V(Red) OPEN 102%~108% OPEN 102%~108% OPEN 102%~108% Fosc : 100KHz +V -V DIM+ ...

Page 4

... Power factor will be higher than 0.9 when output loading is 60% or higher. Constant Current Mode 1.02 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 0.84 60% 70% 80% LOAD EFFICIENCY vs LOAD (48V Model) HLG-150 series possess superior working efficiency that up to 94% can be reached in field applications ...

Page 5

... PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. O/P O Cin F Cout L IC Circuit Switch Adjuster Blue DIM+ White DIM- Black V(-) Red LED Lighting V(+) 0~100K Ohms resistance 1~10V DC Voltage 10V PWM Signal File Name:HLG-150-SPEC 2011-01- ...

Page 6

... A. Add a common mode ferrite choke on output wires to reduce the common emission between 10M ~ 300MHz per lighting EMI regulation. B. Chassis of LED lamp and chassis of HLG-150 or the FG wire should be connected to the safety ground to reduce the EMI noise, including the conduction and radiation emission. ...