MPT-200A Mean Well, MPT-200A Datasheet

Linear & Switching Power Supplies 200W 5V/20A 12V/7.5A -5V/2A

MPT-200A

Manufacturer Part Number
MPT-200A
Description
Linear & Switching Power Supplies 200W 5V/20A 12V/7.5A -5V/2A
Manufacturer
Mean Well
Datasheet

Specifications of MPT-200A

Product
Switching
Commercial/medical
Medical
Output Power Rating
100 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
20 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
7.5 A
Output Voltage (channel 3)
- 5 V
Output Current (channel 3)
2 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AC INPUT VOLTAGE
90~264 VAC, 47~440Hz / 127~370VDC.
POWER FACTOR (Typ.)
PF>0.95/230VAC
AC INPUT CURRENT
Maximum input current 3.5A at 115VAC, 60Hz or
1.6A at 230VAC, 60Hz with 100% output load.
INRUSH CURRENT
Inrush current is less than 25A at 115VAC or
less than 40A at 230VAC under cold start
conditions. Limiting provided by internal
thermistors.
SETUP, RISE TIME
1000ms, 20ms / 230VAC at full load
3000ms, 20ms / 115VAC at full load
HOLD-UP TIME
16ms / 230VAC at full load
16ms / 115VAC at full load
LEAKAGE CURRENT
Leakage current is less than 180 A at 264VAC for
earth leakage current
Leakage current is less than 100 A at 264VAC for
patient leakage current
DC OUTPUT ADJ. RANGE
DC output voltage (or CH1 of multiple output models)
can be adjusted between -5%~+10% rated output
voltage by potential meter.
OVERLOAD PROTECTION
Fully protected against short circuit and output overload.
The hiccup type protection will be activated at 120~160%
rated load and recovers automatically after fault condition
is removed.
OVER VOLTAGE PROTECTION
Provided on output channel 1 only at 115%~135%
rated output voltage.
Output will be shut down when this protection is activated.
OVER TEMPERATURE PROTECTION
When the temperature of TSW1 which detect on heat sink of
power transistor reaches 95
Then output will be shut down and recovers automatically
after temperature goes down.
POWER GOOD / FAIL SIGNAL
TTL logic high for power good and TTL low for
power fail. When the output voltage reaches 90% of
rated value, a +5V TTL signal will be sent out with a
10~500ms delay; At least 1ms before the output
voltage goes below 90% of the rated value, the TTL
signal will be turned off.
* MPS-200-3.3 does not have this function.
REMOTE CONTROL
RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4~10mA
Specification
(Typ.)
1~4 Output Medical Type
(Typ.)
PF>0.98/115VAC at full load
(Typ.)
This protection is activated.
WORKING TEMP.
Whole series can operate from -20~70 . Please refer
to the derating curves.
WORKING HUMIDITY
20~90% RH non-condensing.
STORAGE TEMP., HUMIDITY
-40~+85 , 10~90% RH
TEMP. COEFFICIENT
VIBRATION
2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a
10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes.
SAFETY STANDARDS
Medical UL60601-1, TUV EN60601-1
Commercial : Also design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
4000VAC between input and output
1500VAC between input and F.G.
1500VAC between output and F.G.
ISOLATION RESISTANCE
>100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage.
EMI COMPLIANCE
EMI Specifications
Conducted & Radiation
Harmonic distortion
Voltage flicker
EMS COMPLIANCE
EMS Specification
ESD air
ESD contact
RF field susceptibility
EFT(Electrical Fast Transient)/Burst
Lightning/Surge
Conducted RF susceptibility
Magnetic field immunity
Voltage dip, interruption
Digital phone carrier immunity
MTBF
262,100 hours min. at full load and 25
calculated per MIL-HDBK-217F.
DIMENSION (L*W*H)
177.8x107.2x35.5mm or 7"x4.22"x1.4"
PACKING
0.66Kg; 24pcs/16.8Kg/0.99CUFT
0.04%/
Universal AC input / Full range
Low leakage current <180 A
Protections: Short circuit / Overload / Over voltage / Over temperature
Free air convection for 140W and forced air convection for 200W
UL60601-1 medical safety approved
With power good and fail signal output
Built-in remote ON-OFF control
Built-in remote sense function
Fixed switching frequency at 100KHz
3 years warranty
Features
:
on all outputs at full load between 0~50
2 0 0 W M e d i c a l
,
IEC60601-1
Compliance Level
EN55011, Class B
EN55022, Class B
EN61000-3-2
EN61000-3-3
Compliance Level
EN61000-4-2,
EN61000-4-2,
EN61000-4-3,
EN61000-4-4,
EN61000-4-5,
EN61000-4-6,
EN61000-4-8,
EN61000-4-11,
ENV50204,
of ambient temperature,
File Name:200W MEDICAL-SPEC 2010-10-18
approved
of ambient temperature.
Level 3, 8KV
Level 2, 4KV
Level 2, 3V/m
Level 3, 10V/m
Level 2, 1KV/5KHz
Level 3, 2KV/5KHz
Level 4, 2KV/Line-Line
Level 2, 3Vrms/m
Level 3, 10Vrms/m
Level 2, 3A/m
Level 3, 10A/m
Compliance
Level 2, 3V/m, 900MHz
Level 3, 10A/m, 900MHz
EN60601-1
IEC60601-1
4KV/Line-Earth
s e r i e s

Related parts for MPT-200A

MPT-200A Summary of contents

Page 1

Output Medical Type Specification AC INPUT VOLTAGE 90~264 VAC, 47~440Hz / 127~370VDC. POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load AC INPUT CURRENT (Typ.) Maximum input current 3.5A at 115VAC, 60Hz or 1.6A at 230VAC, 60Hz with 100% output ...

Page 2

... MPS-200-12 12V 16.7A 0A MPS-200-15 15V 13.4A 0A MPS-200-24 24V 8.4A 0A MPS-200-48 48V 4.2A 0A MPD-200A 5V 20A 4A 12V 8A 0.8A MPD-200B 5V 20A 4A 24V 4A 0.4A MPT-200A 5V 20A 4A 12V 7.5A 0.8A - MPT-200B 5V 20A 4A 12V 6A 0.6A -12V 2A 0A MPT-200C 5V 20A 4A 15V 4.7A 0.5A -15V 2A 0A MPT-200D 5V 20A ...

Page 3

Output Medical Type Mechanical Specification(MPS-200) CN1 3[0.118"] max. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment Mating Housing 1 AC/N JST VHR 2 No Pin or equivalent 3 AC/L DC Output ...

Page 4

... AMBIENT TEMPERATURE ( ) 177.8[7"] 165.1[6.5"] 25CFM min. FAN DC Output Connector (CN4) : JS-2008-03*2 or equivalent Terminal Pin No. 1 JST SVH-21T-P1 equivalent Terminal 6 JST SVH-21T-P1.1 or equivalent Static Characteristics (MPD,T,Q-200) 100 90 MPT/Q-200 80 70 MPT/Q-200 (HORIZONTAL) 90 6.35[0.25"] SVR1 LED 1 4 CN4 CN2 CN3 16 4- 3.96[0.156"] Assignment Mating Housing ...