MAP110-4002 POWER ONE, MAP110-4002 Datasheet

Linear & Switching Power Supplies Open Frame 110W (+5V & +/-12V & +12V)

MAP110-4002

Manufacturer Part Number
MAP110-4002
Description
Linear & Switching Power Supplies Open Frame 110W (+5V & +/-12V & +12V)
Manufacturer
POWER ONE
Datasheet

Specifications of MAP110-4002

Product
Switching
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units
bear the CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage
requirements.
Single-Output Model Selection
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
MCD10142 Rev. 1.0, 27-Jan-10
Description
Multiple-Output Model Selection
MAP110-1005
MAP110-1012 12V/15V
MAP110-1024 24V/28V
MODEL
MODEL
MAP110-4000
MAP110-4001
MAP110-4002
MAP110-4003
MAP110-4004
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
5V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
11.25V to 15.75V
4.95V to 5.50V
22.8V to 29.2V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
4.75V to 5.25V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
3.8/3.2A (Note 2)
CONVECTION COOLED
7.5/6A (Note 2)
OUTPUT CURRENT
CONVECTION COOLED
CURRENT (NOTE 1)
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
5A/9A PK
16A
Page 1 of 5
5.0/4.3A (Note 2)
10/8A (Note 2)
OUTPUT CURRENT
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
12A/20A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
FORCED AIR
FORCED AIR
5A/9A PK
5A/9A PK
CURRENT
22A
Features
• RoHS lead-solder-exemption compliant
• New 3.3 V and 5 V output models
• Universal input 85-264 VAC
• Industry-standard footprint: 7.00" x 4.30" x 1.97"
• Input transient & ESD compliance to EN61000-4-2/-3/-4
• Greater than 134,000 hours MTBF
• Remote sense and overvoltage protection on single
• Options include overtemperature protection,
(177.8 x 109.2 x 50.0 mm)
output units and main output of multiple output units
Power Fail signal, chassis, & cover
MAP110 AC-DC Series Data Sheet
REGULATION
REGULATION
0.2%
0.2%
0.2%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
LINE
LINE
REGULATION
REGULATION
0.5%
0.5%
LOAD
0.5%
1.5%
0.5%
0.5%
0.5%
1.5%
0.5%
1%
LOAD
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 2)
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
11.97V to 12.03V
23.94V to 24.06V
11.97V to 12.03V
14.96V to 15.04V
23.94V to 24.06V
11.97V to 12.02V
23.95V to 24.05V
-11.4V to -12.6V
-4.75V to -5.25V
-11.4V to -12.6V
-11.4V to -12.6V
-14.3V to -15.7V
-4.75V to -5.25V
-14.3V to -15.7V
5.09V to 5.11V
5.09V to 5.11V
11.4V to 12.6V
5.09V to 5.11V
11.4V to 12.6V
5.09V to 5.11V
5.09V to 5.11V
14.3V to 15.7V
5.09V to 5.11V
INITIAL SETTING
INITIAL SETTING
ACCURACY
ACCURACY

Related parts for MAP110-4002

MAP110-4002 Summary of contents

Page 1

... Fixed MAP110-4000 -12V Fixed -5V Fixed +5V 4.75V to 5.25V +24V Fixed MAP110-4001 -12V Fixed +12V Fixed +5V 4.75V to 5.25V +12V Fixed MAP110-4002 -12V Fixed +12V Fixed +5V 4.75V to 5.25V +15V Fixed MAP110-4003 -15V Fixed -5V Fixed +5V 4.75V to 5.25V +24V Fixed MAP110-4004 -15V Fixed ...

Page 2

... Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C. Operating Frequency Switching frequency of main transformer, (fixed frequency). MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) CONVECTION COOLED FORCED AIR LINE ...

Page 3

... Input to output. Leakage Current Per EN60950, 264 VAC. NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet MAP110-1005 ...

Page 4

... Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature Shutdown condition. Automatic recovery. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet At 100% load: At 50% load: Page MIN NOM ...

Page 5

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet OVERALL WEIGHT: 1.3 lb (0.59 kg) Page NOTE 1 ...