H5CX-A-N AC100-240 Omron Automation, H5CX-A-N AC100-240 Datasheet

no-image

H5CX-A-N AC100-240

Manufacturer Part Number
H5CX-A-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; REPL:H5CX-AAC1002
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A-N AC100-240

Brand/series
H5CX
Connection Type
Screw Terminals
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
Ultra-compact Timer Provides Advanced
Functions and Security Settings.
Basic Features
Safety and Reliability
Other Features
*1. For 100 to 240 VAC Models with Screw Terminals 78 mm, Models with Sockets: 63.7 mm
*2. The H5CX-A11, H5CX-L8 and H5CX-B Timers have only red characters.
*3. Specifications: 100 to 240 VAC
*4. Replacement Front Panels sold separately.
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner
control panels. (Models with Screw Terminals)
Easier to Read
For better readability, the character height for the present value display
is 12 mm (on models with 4 digits), the largest class in the industry. The
wide viewing angle and brightness provide excellent visibility.
The number of display segments has also been increased to make
settings easier to understand, and the present value display can be
switched between red, green and orange so that output status can be
seen from a distance.
Model with 4 Digits Model with 6 Digits
Note: The H5CX-A11 and H5CX-L8 Timers have only red characters.
The Easiest Operation
Operation is simplified by the
Up/Down Keys for each digit
on 4-digit models and Up Keys
for each digit on 6-digit
models.
• Short body with depth of only 59 mm (for 24-VAC / 12 to 24-VDC Models with
• Character height of 12 mm for better readability (on models with 4 digits).
• The present value display characters can be switched between red, green,
• Power supply circuit and input circuits are isolated for safety and reliability.
• New set value limit and output counter functions have been added.
• Front Panel can be changed to white or light gray.
• Models with instantaneous contact output added to the series.
24-VAC / 12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC / VDC Models with Screw Terminals: 78 mm
Models with Sockets: 63.7 mm (case dimension)
* The shortest body for a timer with isolated power supply and input circuits and a maximum
Digital Timer
H5CX-@-N
Screw Terminals).
and orange.
(case dimension).
ambient temperature of 55°C (according to OMRON investigation in June 2009).
New Product
12 mm
(actual size)
(Display example)
*2
*1
10 mm
(actual size)
New models
Model with 4 Digits
Easy to read from the top, bottom, and sides!
models
New
Previous
models
Previous
models
*
Model with 6 Digits
*4
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated for safety and
reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if
wired incorrectly. The New H5CX removes these worries.
*1. New Models (H5CX-@-N) with 100 to 240-VAC specifications.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Output Counter
The output counter counts the number of times the output turns ON
(alarm display, count monitoring, count in increments of 1,000). This
counter is useful in managing the service life of the Timer or the load.
*2. The AC power supply ground is on the commercial power supply side.
*3
AC power
supply
*2
Previous
H5CX
Input terminal
0-V terminal
Worry-free operation
is achieved with the
New H5CX by
restricting the time
that can be set.
Refer to “Safety Precautions” on page 41.
Output terminal on PLC
or other device
Stabilized DC
power supply
–V
COM terminal
+V
Forget These
Worries with the
New H5CX
*1
1

Related parts for H5CX-A-N AC100-240

H5CX-A-N AC100-240 Summary of contents

Page 1

... Models with instantaneous contact output added to the series. *1. For 100 to 240 VAC Models with Screw Terminals 78 mm, Models with Sockets: 63.7 mm (case dimension). *2. The H5CX-A11, H5CX-L8 and H5CX-B Timers have only red characters. *3. Specifications: 100 to 240 VAC *4. Replacement Front Panels sold separately. ...

Page 2

... Twin Timer Mode: 4 modes NPN/PNP input NPN input 11-pin socket 8-pin socket 4 None Supported Not supported Provided None 100 to 240 VAC or 24 VAC/ VDC Six-digit Type H5CX-B Series H5CX-L8E@-N H5CX-B@- Yes Timer Mode : 4 modes Timer Mode: 2 modes Twin Timer Mode : 2 modes None NPN/PNP input ...

Page 3

... A: Signal ON Delay I H5CX-B 0.1 to 99999.9 min F-1: Cumulative 0.1 to 99999.9 h Note: 1. The functions that are provided depend on the model. Check detailed specifications before ordering. 2. Refer to page 33 and later for information on H5CX-B Timers (6-digit display). 2. External Connections Symbol Meaning None Screw terminals ...

Page 4

... H5CX-L8@ Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. H5CX-A11@ Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. H5CX-L8@ A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. H5CX-A11@ Remarks Page --- 14 Remarks Page 13 ...

Page 5

... Switch the display color* between red, green, and orange to see the output status from a distance. • Up/Down Keys for each digit enable easy operation. • Cyclic control is easy with the Twin Timer and Variable ON/OFF Duty modes. * Not supported by the H5CX-A11@ or H5CX-L8@. Specifications Ratings Item Models ...

Page 6

... If the set value is within the sensor waiting time at startup the control influences) output of the H5CX will not turn ON until the sensor waiting time passes. Note: 1. The values are based on the set value. 2. The value is applied for a minimum pulse width of 1 ms. ...

Page 7

... Immunity Conducted Disturbance: Immunity Burst: Immunity Surge: Immunity Voltage Dip/Interruption: *1. The following safety standards apply to models with sockets (H5CX-A11@ or H5CX-L8@). cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. *2. Excluding the H5CX-ASD-N/-A11SD-N/-L8SD-N. ...

Page 8

... Unused (-) (+) H5CX-L8-N/-L8D-N Internal circuit Signal 4 5 Reset 3 6 Contact 2 7 output Terminals 1 and 2 of the H5CX-L8D-N are connected internally. (-) (+) H5CX-L8E-N/-L8ED-N Internal circuit Internal circuit Time-limit Instantaneous contact output contact output 2 7 OUT2 OUT1 1 8 (–) (+) Note: Do not connect unused terminals as relay terminals ...

Page 9

... Internal IN IN circuit Input Connections The inputs are no-voltage (closed or open) inputs or voltage inputs except for the H5CX-L8@. (The inputs of the H5CX-L8@ are no-voltage inputs only. The H5CX-L8E@ does not have an input.) No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or ...

Page 10

... Present Value Display (Main display) * (Character height: 12 mm, red ) * Characters on models with screw terminals (H5CX-A@) can be switched between red, green, and orange. 5. Time Unit Indicators (Color is same as present value display.) (If the time range is 0 min 0 min, these indicators flash to indicate timing operation.) 6 ...

Page 11

... Dimensions with Flush Mounting Adapter H5CX-A-N/-AS-N (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing 58 48 H5CX-AD-N/-ASD-N (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing 58 48 H5CX-A11@-N (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) ...

Page 12

... If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54 against oil. Do not, however, use the H5CX in locations where it would come in direct contact with oil. Flush Mounting Adapter ...

Page 13

... RESISTIVE 7.8 5 4.5 Dimensions 27 dia 45 4 dia 25.6 4.5 6.2 45 16.3 H5CX-A@-N/-L@-N Terminal arrangement Mounting hole and internal connections dimensions Two 4.5-dia. holes 40 ±0.2 Note: The Socket can also be mounted DIN track. (Top View Two 4.5-dia. holes 4 40 ± ...

Page 14

... H5CX-A@-N/-L@-N Terminal Covers for P3G-08 and P3GA-11 Back-connecting Sockets Model Y92A-48G Twelve, 6.4 dia 34 Y92A-48G Note: The Terminal Cover can be used with a Back-mounting Socket (P3G-08 or P3GA-11) to create a finger-safe construction. Optional Products for Track Mounting Mounting Track PFP-100N PFP-50N Mounting Track ...

Page 15

... It is not necessary to mount the Waterproof Packing if waterproof construction is not required. Operating Procedures for Timer Function Step1 Settings for basic functions can be performed with just the DIP switch. Note: There is no DIP switch on the H5CX-L8 Key-protect Switch Item 1 DIP switch settings ...

Page 16

... Note: Displayed only for models with terminal screws (H5CX-A@). Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1) using the Keys. 1c1c 2c (Instantaneous) (Time-limit) Note: Displayed only for models with instantaneous contact outputs. ...

Page 17

... ON count alarm set value Instantaneous output 1 (OUT1) ON count monitor value Instantaneous output 2 (OUT2) ON count monitor value H5CX-A@-N/-L@-N Timer keys. kp-6 kp-7 (KP-6) (KP-7) keys 9999 (0 x 1000 times) (9999 x 1000 times) Note: The monitor value is only displayed. It cannot be set. ...

Page 18

... Set an NPN input when using a 2-wire sensor. For details on input connections, refer to "Input Connections" on page 9. 18 Display Color (colr) (Terminal block model: H5CX-A@ only) Set the color used for the present value. Output OFF red Red (fixed) grn ...

Page 19

... Set the cycle time. Set each digit for the output time using the corresponding Note: H5CX-L8E@-N Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. Set each digit for the output time using the corresponding (The keys for the 4th digit cannot be used ...

Page 20

... H5CX-A@-N/-L@-N Timer Timing Charts Operating Procedures for Timer Function Models without Instantaneous Contact Outputs The gate input is not included in the H5CX-L8@ models. Mode A: Signal ON delay 1 (Timer resets when power comes ON.) Basic operation Power * Start signal input Timing Output * Start signal input is disabled during timing. ...

Page 21

... Set value UP 0 Set value DOWN 0 Detailed operation Sustained Output Power Start signal Gate Reset Control output Set value UP 0 Set value DOWN 0 One-shot Output Power Start signal Gate Reset t t Control output Set value UP 0 Set value DOWN 0 H5CX-A@-N/-L@-N Timer ...

Page 22

... OFF or when the power is OFF). A sustained control output is used. Note: Output is instantaneous when setting is 0. When the H5CX is used with power start in mode F mode or F-1 (i.e., cumulative operation with output on hold), there will be a timer error (approximately 100 ms each time the H5CX is turned ON) due to the characteristics of the internal circuitry ...

Page 23

... OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms. Note: H5CX-L8E@-N Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. Detailed operation Power ...

Page 24

... OFF. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms. Note: H5CX-L8E@-N Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. 24 Detailed operation ...

Page 25

... Hold down for 1 s min. Run mode 1 + Hold down for 1 s min. Step2 Settings for basic functions can be performed with just the DIP switch. Note: There is no DIP switch on the H5CX-L8 Key-protect Switch Item OFF 1 DIP switch settings Disabled 2 OFF time range Refer to the table on the right ...

Page 26

... OFF start 1 On Start 1 OFF start 2 On Start 2 Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CX-L8E@. Set the input signal width using the keys. 20ms 1ms (20 ms) (1 ms) Note: Not displayed for models with instantaneous contact outputs. ...

Page 27

... ON count alarm set value Instantaneous output 1 (OUT1) ON count monitor value Instantaneous output 2 (OUT2) ON count monitor value H5CX-A@-N/-L@-N Twin Timer keys. keys. kp-6 kp-7 (KP-6) (KP- 9999 (0 x 1000 times) (9999 x 1000 times) Note: The monitor value is only displayed. It cannot be set. ...

Page 28

... Set an NPN input when using a 2-wire sensor. The same setting is used for all external inputs. For details on input connections, refer to "Input Connections" on page 9. Display Color (colr) (Terminal black model: H5CX-A@ only) Set the color used for the present value. red grn org ...

Page 29

... Timing Charts Operating Procedures for Timer Function Models without Instantaneous Contact Outputs The gate input is not included in the H5CX-L8@ models. Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.) Basic operation Power * Start signal input Timing Timing Timing Timing OFF ...

Page 30

... OFF. Note: Normal output operation will not be possible if the set time is too short. Set the ON time and OFF time to at least 100 ms. Note: H5CX-L8E@-N Precautions Set the Timer’s set value before using the Timer in a self-holding circuit. 30 Detailed operation Power ...

Page 31

... Timer/Twin Timer Selection Mode (Function Selection) Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode. The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. ...

Page 32

... H5CX-A@-N/-L@-N Key Protect Level When the key-protect switch is set to ON possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7). The key protect indicator is lit while the key-protect switch is set to ON. * Factory-set to OFF ...

Page 33

... Digital Timer H5CX-B@-N • H5CX Digital Timers with 6-digit Display, 2-stage Setting, and Forecast Output (DIN 48 x 48-mm) • Times the daily operating hours of machinery and tools, predicting and notifying when maintenance is required. • Easy-to-read backlit negative LCD with 6 digits (displays to 99999.9 h). • ...

Page 34

... Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.) and setting error If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting (including temperature and time passes. ...

Page 35

... Terminals 7 and 10 are not connected internally, however, so OUT 2 do not use them for cross-over wiring. (–) (+) Input Connections The inputs of the H5CX-B are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Open Collector Voltage Output PLC or Sensor sensor ...

Page 36

... The Key-protect Switch can be turned ON and OFF while the power is ON. Dimensions Digital Timers Digital Timers H5CX-BWSD-N (Flush Mounting Models) Note: M3.5 terminal screw (effective length: 6 mm) Dimensions with Flush Mounting Adapter H5CX-BWSD-N (Provided with Adapter and Waterproof Packing) 58 Accessories (Order Separately) Refer to page 12 for details ...

Page 37

... OFF min 0.1 min to 99999.9 min Key. Absolute Value Setting Key is pressed, H5CX-B@-N ON OFF Present value Set value 1 Each time the Key is pressed, the sub-display will switch between set value 1 (“SET 1” is lit) and set value 2 (“SET 2” is lit). ...

Page 38

... H5CX-B@-N Operation in Function Setting Mode Settings that cannot be performed with the DIP switch are performed with the operation keys. • Change to Function Setting Mode. Power min. Run mode Function setting mode * min. *1. If the mode is switched to the function setting mode during operation, operation will continue. ...

Page 39

... Refer to pages 18 and 28 for information on other functions. Error Output status Either press the Reset Key or OFF reset the power supply. OFF Reset the power supply. *1 OFF Reset Key. No change Reset Key H5CX-B@-N Present value Correction method Set value after reset No change No change Factory setting No change 39 ...

Page 40

... When the H5CX is used with power start in mode F mode or F-1 (i.e., cumulative operation with output on hold), there will be a timer error (approximately 100 ms each time the H5CX is turned ON) due to the characteristics of the internal circuitry. Use the H5CX with signal start if timer accuracy is required. ...

Page 41

... Do not use the Timer where subject to flammable or explosive gas. Fire may occasionally occur. Tighten the terminal screws to the rated torque. H5CX terminals: 6.55 to 7.97 lb-in (0. P2CF Socket terminals: 4.4 lb-in (0 • Minor injury due to electric shock may occasionally occur. Do not touch any of the terminals while power is being supplied ...

Page 42

... H5CX-@-N Precautions for Correct Use • H5CX models with a 24-VDC/12 to 24-VDC power supply use a transformer-free power supply method in which the power supply terminals are not isolated from the signal input terminals non- isolating DC power supply is used, unwanted current paths may occasionally burn or destroy internal components depending on the wiring. Always check the wiring sufficiently before use. • ...