BNL-6 IDEC Corporation, BNL-6 Datasheet - Page 30

no-image

BNL-6

Manufacturer Part Number
BNL-6
Description
Accessory, Din Rail End Stop
Manufacturer
IDEC Corporation
Datasheet

Specifications of BNL-6

Application
Industrial, water level controls, valves & pump controls, conveyer system, food processing, machine, coin-operated car wash, commercial, elevator & escalator, lighting control, security system, residential, sprinkler system, garage door control, ventilati
Brand/series
FL1C Series
Standards
cUL Listed, CE Marked
Lead Free Status / Rohs Status
RoHS Compliant part
F
Instructions
Mounting Snap-Mount Sockets
Mounting Relay Holders
Mounting Hold-Down Springs
F-30
Take the two anchor clips (horseshoe / U-shaped
piece) that come with the socket and insert into
the slits on both sides of the socket. Make sure the
raised notches on the anchor clip face into the
socket.
Plug relay into socket
Insert the open ends of the hold-down spring into
either the first or second hole of the anchor clip.
The relay-spring combination will determine which
hole should be used.
Slide spring over relay.
Figure 1
Remove
Figure 2
Mount
RH-01 or -03
Figure 1
Figure 2
www.idec.com
Snap-mount sockets are designed to mount on the BNDN-1000
mounting rail. The built-in mounting clip eliminates mounting hard-
ware and reduces mounting time by 80%.
To mount see Figure 1. Place the end of the socket (end opposite of
mounting clip against the outer edge of the rail). Press the socket
down firmly until the clip snaps onto the mounting rail. To remove
see Figure 2. Pull out the mounting clip with a screwdriver, and lift
the socket.
For spacing between adjoining sockets, use the SA-406 DIN rail
spacer. Spacers are 0.195" wide. Spacing can be adjusted accord-
ing to the number of spacers added. Spacers snap on and off easily
like snap-mount sockets.
To prevent side-to-side movement, use a BNL-5 end clip at each
end of every socket row.
Mount directly onto panel boards in two alternate
positions: A and B (see Figure 1).
To mount the relay into the holder, hook the bottom
edge of the relay case (coil terminal side) onto the
relay holder (see Figure 2).
Push down until the relay snaps into place.
Instructions
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
Hold-Down Spring

Related parts for BNL-6