BNL-6 IDEC Corporation, BNL-6 Datasheet - Page 8

no-image

BNL-6

Manufacturer Part Number
BNL-6
Description
Accessory, Din Rail End Stop
Manufacturer
IDEC Corporation
Datasheet

Specifications of BNL-6

Application
Industrial, water level controls, valves & pump controls, conveyer system, food processing, machine, coin-operated car wash, commercial, elevator & escalator, lighting control, security system, residential, sprinkler system, garage door control, ventilati
Brand/series
FL1C Series
Standards
cUL Listed, CE Marked
Lead Free Status / Rohs Status
RoHS Compliant part
F
SU Series: DIN Rail Snap-Mount
F-8
SU9Z-J5 Jumper for SU2S-11L and SU4S-11L
The SU9Z-J5 is used to install five sockets. When installing less than five
sockets cut the jumper according to the instructions listed to the right.
The SU9Z-J5 jumper is for coil terminals only.
Installation
Loosen the marking plate on the socket.
Alignment
Making sure that the SU9Z-J5 jumper is correctly aligned, insert the blades
into the ports in the groove of the SU sockets.
Install Jumper Securely
Press down the marking plate to secure the jumper. The jumper installation is
now complete.
Rated Current
Material
Incorrect
Jumper port
for terminal 14
Insertion Direction
Conductor
Sheath
SU9Z-95 Jumper
A: Loose fitting
Jumper Groove
www.idec.com
3A
Nickel-plated brass
ABS resin
Correct
SU Series: SU9Z-J5 Jumper Installation Instructions
Grooves for marking plate ribs
(on both sides)
Ribs
Jumper
B: Installed securely
Blade
Jumper port
for terminal 13
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Installing Two, Three or Four SU Sockets on the SU9Z-J5
Jumper
As shown below, slide the jumper in the sheath so that the jumper aligns with
the center of the sheath.
With the sheath properly installed on the jumper, cut the sheath and
jumper at the points shown below, using cutting pliers. Referring to the
drawing on the right, make sure that the sheath and jumper are cut
within the cutting area. Dispose of unused portions according to local
waste disposal requirements.
After cutting the jumper and sheath, slide the jumper as shown below, so that
the ends of the jumper ar e not exposed.
Jumper Wiring to Six or More SU Sockets
To jumper wire six or more SU sockets, connect five sockets using whole
jumpers and the remaining sockets using a cut jumper. Then connect the two
terminals on adjoining sockets using an applicable wire (see table below).
Safety Precautions
Turn off the power to the SU9Z-J5 jumper before starting installation,
removal, wiring, maintenance, or inspection of the jumper. Failure to turn
power off may cause an electrical shock or fire hazard.
To avoid a short circuit due to incorrect wiring, confirm which terminals are
connected to the jumper before beginning wiring.
2 Sockets
2 Sockets
3 Sockets
4 Sockets
Stranded wire
Solid wire
AWG
Jumper off center
A
1. Use a wire with cable insulation diameter of ø3.15mm
2. Strip the cable insulation 9 to 10mm from the end.
maximum.
X
Wire
B
Y
2
1
1
C
Qty
Z
Sockets
A, C
A, B
D
Cutting Area
0.2 to 1.25 mm
0.2 to 1.5 mm
24 to 16
Cutting Area C
Proper wire
Cutting Area in Detail
2
2
Size
Y
X
Z
Jumper on center
Discard
Cutting Area D
Shea
Jump
Shea