ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
• Monitors one dual-channel normally closed Emergency Stop switch circuit for
• Four output switching channels for connection to control-reliable power interrupt
• Auto reset or monitored manual reset
• Design complies with standards UL 991, EN 418, and EN 954-1 (Category 4)
• For use in functional stop category 0 applications per NFPA 79 and
• 6 amp safety output contacts
• Plug-in terminal blocks
• 12-24V dc/115V ac or 12-24V dc/230V ac operation
• External Device Monitoring (one-channel EDM)
a contact failure or wiring fault
circuits
IEC/EN 60204-1
Emergency Stop Safety Modules
Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES-VA-5A for 12-24V dc/230V ac operation
08/06
EMERGENCY STOP DEVICE
29YL
Features
P/N 122365 rev. B

Related parts for ES-UA-5A

ES-UA-5A Summary of contents

Page 1

... Emergency Stop Safety Modules Model ES-UA-5A for 12-24V dc/115V ac operation; Model ES-VA-5A for 12-24V dc/230V ac operation EMERGENCY STOP DEVICE 29YL • Monitors one dual-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault • Four output switching channels for connection to control-reliable power interrupt circuits • ...

Page 2

... RMA (Return Merchandise Authorization) number for your paperwork, and give you the proper shipping address. 2. Pack the E-Stop Safety Module carefully. Damage which occurs in return shipping is not covered by warranty. 118.0 mm (4.65") Figure 7. Model ES-UA-5A/ES-VA-5A E-Stop Safety Module enclosure dimensions 10 – Models ES-UA-5A and ES-VA-5A Repairs 45 mm (1.77" (3.3" ...

Page 3

... Supply Voltage and Current A1-A: 115V ac (Model ES-UA-5A) or 230V ac (model ES-VA-5A), ± 15%; 50/60Hz B1-B: 12-24V dc, ± 15%, 10% max. ripple Power consumption: approx. 4W/7VA Supply Protection Circuitry Protected against transient voltages and reverse polarity Output Configuration Outputs (K1 & K2): four redundant (total of eight) safety relay (forced-guided) contacts – AgNi, 5 µm gold-plated, plus 1 N/C Auxiliary Monitor output – ...

Related keywords