UPA100 ATC Diversified Electronics, UPA100 Datasheet

no-image

UPA100

Manufacturer Part Number
UPA100
Description
Power Alert; 750 VAC/1000 VDC; -20 to degC; cULus Listed, CSA Certified
Manufacturer
ATC Diversified Electronics
Datasheet

Specifications of UPA100

Temperature, Ambient
-20 to +55 °C
Termination
6’ (4) 18 AWG
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPA1001C
Manufacturer:
NS
Quantity:
6 219
UPA-100
SERIES
Universal Power Alert
DIMENSIONS
INCHES
PANEL MOUNT
NEMA 4X
FEATURES
2.00
• Verification of Zero Energy
• Detects Single or 3-Phase AC Voltage
• Detects DC or Stored Energy
• Redundant Circuitry
OPERATION
With the green (GND) wire connected to earth ground, the eight
detector UPA-100 visually alerts to the presence of dangerous AC
or DC (Stored Energy) potentials occurring between any combination of
the four monitored input lines (L1, L2, L3, GND). Two LED indicators
are assigned to each input line and are designated "+" and "-". For each
input line carrying an AC potential (bi-polar), both the "+" and "-" LEDs
will be active. A DC or Stored Energy potential will illuminate the "+"
LED for the positive line and the "-" LED for the negative line.
OSHA 1910.147 THE CONTROL OF
HAZARDOUS ENERGY (Lockout/Tagout).
Following the application of lockout or tagout devices to energy isolating
devices, all potentially hazardous stored or residual energy shall be
relieved, disconnected, restrained, and otherwise rendered safe.
(d)(5)(ii)
PANEL
If there is a possibility of reaccumulation of stored energy to a hazardous
KNOCKOUT
level, verification of isolation shall be continued until the servicing or
maintenance is completed, or until the possibility of such accumulation
no longer exists.
1 11/16
(d)(6)
1 1/4 CONDUIT
"Verification of Isolation." Prior to starting work on machines or
equipment that have been locked out or tagged out, the authorized
employee shall verify that isolation and de-energization of the machine
or equipment have been accomplished.
www.automatictiming.com