OA-50 SELCO, OA-50 Datasheet - Page 37

no-image

OA-50

Manufacturer Part Number
OA-50
Description
Disc Thermostat; 1/2 in; opens 50 degF; auto reset 32 degF; surface mt, sol tabs
Manufacturer
SELCO
Datasheet

Specifications of OA-50

Body Style
Disc
Brand/series
OA
Current Rating
15⁄10 A
Dielectric Rating
1500 VAC per 1 Minute
Dimensions
1.18 in. L × 0.570 in. W × 0.395 in. H
Function
Thermostat
Mounting Style
Surface Mount
Output
NC
Primary Type
Thermostat
Resistance, Insulation
100 Megohms
Standards
UL & cUL Listed, CSA Certified, VDE Approved
Technology
Thermal Conductive
Termination
Solder
Thermostat Type
Disc
Voltage, Supply
250 VAC
KS Series - Temperature Control with S.P.S.T. Switch and Automatic Defrost
(714) 917-1333
I t i s t h e c u s t o m e r ’s s o l e r e s p o n s i b i l i t y t o s p e c i f y a n d d e t e r m i n e t h e s u i ta b i l i t y o f a pa r t i c u l a r
c o n t r o l o r c o m p o n e n t b a s e d o n t h e i r u n i q u e i n d i v i d u a l a p p l i c a t i o n s a n d r e q u i r e m e n ts
(800) 257-3526
C o l d C a p i l l a r y C o n t r o l s
www.selcoproducts.com
FAX (714) 917-1355
APPLICATIONS
Closing with rising temperature and possibility to manually
initiate a defrost function is achieved by pressing the defrost
pin (stroke approximate .157 (4mm)) until latching. By doing
this, the main switch is opened and locked until the defrost
temperature is reached at the sensing point of the capillary
which is normally fixed at the evaporator. After the defrost
temperature has been reached, the pressure pin returns to
its OFF position and the normal ON/OFF operation of the
temperature control is reset. Defrost function can be initiated
in any position of the dial shaft. If initiated in error, the defrost
function can be cancelled by turning the dial shaft to the OFF
position.
Terminal 3-4: Closes on temperature rise
Electrical ratings
Inductive load ratings
Temperature range
Adjustment range
Differential
Defrost temperature
Tolerance
Contact resistance
Insulation resistance
Dielectric strength
Approvals
Typical Electrical Wiring Diagram
3-4
Automotive air conditioning
Refrigerating/freezing devices
C
Main switch closes at temperature rise
Compressor
E-mail: sales@selcoproducts.com
SPECIFICATIONS
250V, 6 Amps, 50Hz
250V, 6FLA, 36LRA
120V, 10FLA, 40LRA
-40ºF to 104ºF (-40ºC to 40ºC)
4 to 14K
4 to 14K
Possible between 2ºC and 10ºC
Differential of defrost temperature to
WARM -IN minimum 4K
2.7ºF (1.5ºC) at calibration point
3.6ºF (2.0ºC) at non-calibration point
4.5ºF (2.5ºC) at defrost
<50m S
>100M S
AC 50/60Hz, 1500V/1 minute
UL, C-UL, VDE
Typical Function Chart