CA-110 SELCO, CA-110 Datasheet

no-image

CA-110

Manufacturer Part Number
CA-110
Description
THERMOSTAT
Manufacturer
SELCO
Datasheet

Specifications of CA-110

Body Style
Disc
Brand/series
CA
Current Rating
15⁄10 A
Dielectric Rating
1500 VAC per 1 Minute
Dimensions
1.18 in. L × 0.570 in. W × 0.395 in. H
Function
Thermostat
Material, Housing
Phenolic
Mounting Style
Surface Mount
Mounting Type
Flat Surface
Output
NO
Primary Type
Thermostat
Range, Measurement
150 °C
Resistance, Insulation
100 Megohms or More
Standards
UL & cUL Listed and CSA Certified, VDE Approved, CE Marked
Technology
Thermal Conductive
Temperature, Operating, Maximum
160 °C
Temperature, Operating, Minimum
10 °C
Termination
Solder
Thermostat Type
Disc
Voltage, Supply
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
S E L C O P R OD UCT S CO M PA NY
THERMOSTATS
ELECTRONIC CONTROLS
ISO 9001/AS 9100 Certified Quality System
Our Service Makes The Difference
1/2” Disc Thermostats
1/2” Disc Hermetically Sealed Thermostats
3/4” Disc
Thermostats
Encapsulated Thermostats
Thermal Protectors
Printed Circuit
Board Thermostats
One-Shot Thermal Cut-offs
Probe Thermostats
Cold Cap-
illary Thermostats
Adjustable Thermostats
Hot Bulb & Capillary Thermostats
Value Added Services
NTC Thermistors
PPTC Thermistors
CdS Photo-
cells
Electronic Controls
Digital Panel Meters
Control Knobs
w w w . s e l c o p r o d u c t s . c o m

Related parts for CA-110

CA-110 Summary of contents

Page 1

... Value Added Services cells Electronic Controls UCT ELECTRONIC CONTROLS 1/2” Disc Hermetically Sealed Thermostats Thermal Protectors NTC Thermistors PPTC Thermistors Digital Panel Meters Printed Circuit Probe Thermostats Hot Bulb & Capillary Thermostats Control Knobs 3/4” Disc Cold Cap- CdS Photo- ...

Page 2

... Founded in 1958 by Bill Wilkinson, Selco Products’ corporate headquarters is in Anaheim, California. Our sales force consists of direct and manufacture representatives throughout North America and Mexico. Every member of our customer support team is dedicated to - providing you with knowledgeable assistance, timely response to special requirements, and prompt delivery of your order. ...

Page 3

... Close CA-85-QC 67 ± 10 Close CA-100 70 ± 10 Close CA-104-ST-18 86 ± 10 Close CA-107-QCV 90 ± 10 Close CA-110 80 ± 10 Close CA-110-PCB 80 ± 10 Close CA-110-QC45 80 ± 10 Close CA-115-QC 100 ± 10 Close CA-120 90 ± 10 Close CA-120-QC 90 ± 10 Close CA-120-QCH 90 ± 10 Close CA-120-QCV 90 ± 7 Close CA-130-QC 110 ± 10 ...

Page 4

... Open OA-175-QCH 175 ± 5 Open OA-175-S2 175 ± 6 Open OA-180 180 ± ’ (714) 917-1333 (800) 257-3526 CA - Close On-Rise (normally open) Close ºF Mounting 170 ± 7 surface 170 ± bracket 175 ± 7 surface 180 ± 7 surface 180 ± 7 rotating 185 ± 7 6-32 stud 190 ± ...

Page 5

... Open OA-300 300 ± 7 Open OA-300-QC 300 ± 7 Open OA-300-QCVR 300 ± ’ (714) 917-1333 (800) 257-3526 CA - Close On-Rise (normally open) Close ºF Mounting 150 ± 10 surface 150 ± 10 surface 150 ± 10 rotating bracket 167 ± 10 rotating bracket 154 ± 10 surface 131 ± ...

Page 6

... Fireplaces Vacuum cleaners This line of highly reliable switches utilize a snap-action bimetal disc, electrically and thermally isolated from the switch. The contacts are normally closed and open on rise when surface or ambient temperature set point is reached. The circuit will remain open until the manual reset button is depressed at approximately 30% below operating temperature. All models are 100% temperature tested which can be calibrated to your specification at the factory ...

Page 7

... ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com Code AU Stainless Fixed Surface Code QL Stainless Fixed Surface Aluminum Cap Stud Mount - Brass Stud Mount Available In Code SO (6-32) Code SM3 (M3) Code ST (8-32) Code SM4 (M4) Code S2 (10-32) FAX (714) 917-1355 E-mail: sales@selcoproducts.com Code BO Aluminum No Bracket Code QF ...

Page 8

... Quick Connects @ 30º ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com Code SV Solder Vertical Code TH .187 Quick Connects Horizontal Code PCB Printed Circuit Board FAX (714) 917-1355 E-mail: sales@selcoproducts.com Code BH .250 Quick Connects Horizontal Code TV .187 Quick Connects Vertical Code T3H .187 Quick Connects Horizontal ...

Page 9

... CR/OR (622A) Series - Standard Case 622P Series - 4 Post Design (pictured above) Models available from stock - subject to availability Open On-Rise Model Number Open OR-222* Open OR-285* Open OR-325** Open OR-350-QC** Open OR-350-QCV** Open OR-365-QC** * 4-Post design ** Standard case ’ (714) 917-1333 ...

Page 10

... These snap-action bimetal discs are housed in a ceramic case to handle extremely high temperatures. The increased factory calibrated set points are available up to 500ºF (260ºC). The contacts can either open or close on temperature rise. All models are 100% temperature tested before leaving the factory. ...

Page 11

... Code BO Aluminum No Bracket Code FF Stainless Moveable Surface Available for 622 Series only ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com Code QL Stainless Moveable Surface Aluminum Cap Code QD Stainless Moveable Surface FAX (714) 917-1355 E-mail: sales@selcoproducts.com Code IO Stainless Fixed Air ...

Page 12

... Code BV .250 Quick Connects Vertical Code TH .187 Quick Connects Horizontal ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com Code BH .250 Quick Connects Horizontal Code SH Solder Tabs Horizontal FAX (714) 917-1355 E-mail: sales@selcoproducts.com Code TV .187 Quick Connects Vertical ...

Page 13

... Function Model 602S CA/OA Series - 1/2” Automatic Reset 603U-H OM Series - 1/2” Manual Reset 622A CR/OR Series - Standard Case - 1/2” Automatic Reset 622P CR/OR - 4-Post Case - 1/2” Automatic Reset 625A CRA/ORA - High Temperature - 1/2” Automatic Reset Contacts ...

Page 14

... ” The Selco hermetically sealed thermostat is a snap-action disc control. Its welded, hermetically sealed construction was designed for applications where maximum shock and vibration resistance is required. The steel case provides protection from dust and moisture. Terminals are a solder type or weld and lead wires are available. ...

Page 15

... Selco’s direct sensing thermostats are larger than our standard thermostats, giving them an even more powerful bimetallic disc and a higher electrical rating. They are ideal for use with heating and air conditioning systems as well as with industrial equipment. These models are designed for maximum airflow around the thermostat to give quick and accurate response ...

Page 16

... Only the temperature of the controlled equipment or its adjacent environment causes the switch to actuate. Switch operation is rapid and positive due to the characteristics of the bimetallic disc and wiping action of the current carrying contacts. Contact chattering is virtually eliminated false cycling and sparking. The thermostats are enclosed in compact, rugged, tamper-proof cases designed for quick and easy installation in the controlled equipment ...

Page 17

... Made to open on temperature rise, these SPST devices are available in a variety of mounting Temperature calibrations are preset and typically built to order. These units are not considered as “M2” trip free devices. Consult Selco for additional models available from stock. Models available from stock - subject to availability Limit Controls ...

Page 18

... Code 0 -0º Code 60 -60º Code 150 -150º ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com Code 30 -30º Code 90 -90º FAX (714) 917-1355 E-mail: sales@selcoproducts.com Code 45 -45º Code 135 -135º ...

Page 19

... SE Series - Airstream Mount - refer to pages 17-19 T11 SES Series - Surface Mount - refer to pages 17-19 Reset 1 Automatic 2 Manual 3 Single operation Electrical Function 1 Open on-rise (normally closed) 2 Close on-rise (normally open) 3 Single pole - double throw Terminal Type 3 .250 quick connects - Faston (6.3mm - male) ...

Page 20

... Models T21 and T22 are available with #14 gauge wire. Numerous types of terminals can be furnished at an extra cost. For use in millivolt applications, the T Series carries a 12Vdc, 250mA rating. T16 Model - Without Bracket Stainless steel cover T17 Model - Auxiliary Clip Mount Stainless steel cover - 3/8” ...

Page 21

... T21 Model - With Bracket Stainless steel cover T22 Model - Auxiliary Clip Mount Stainless steel cover - 3/8” and 1/2” clips T60 Model - Plastic Body ’ (714) 917-1333 (800) 257-3526 FAX (714) 917-1355 www.selcoproducts.com E-mail: sales@selcoproducts.com ...

Page 22

... T17, T22 and T60 models only) 2 1/2” (T22 model only) 3 5/16” (T60 model only) T17 1 Model Electrical Function ’ (714) 917-1333 (800) 257-3526 Build Your Own Part Set Point (ºF) Differential (ºF) Example Part Number 60 20 Set Point (ºF) Differential (º ...

Page 23

... Alarm signal controller The OP6 Series (OP6, OP61, OP62) thermal protectors close an electrical circuit. They are a snap-action device with quick make/quick break, fast sensing and switching action. These self-resetting devices feature a reinforced PBT-enclosure which make additional sleeving unnecessary. Various leads and terminations are available ...

Page 24

... Snap-action bimetal technology The PBT enclosed UI2 Series offers both thermal conductivity and electrical insulation with no need for additional insulation sleeves. With its large current carrying capacity, the UI2 Series is ideal for more demanding applications and solutions. Variation UI2 Temperature range Temperature tolerance ...

Page 25

... Models UB8P (exposed model - shown above) and UB81P (enclosed model) Self-Hold Thermal Cut-Out and Thermal Protectors are designed to provide overheat protection in high voltage applications. With a high 16 Amp capability, the new models are well suited for thermal overload protection in a broad range of applications. ...

Page 26

... Average First Cycle Tripping Time Delta Temperature vs. Current (25ºC Ambient) Approximation used only for selecting samples for verification tests. Note: Delta T is the difference between the zero current calibrated opening temperature (T cal ) and ambient temperature (T ambient ) at the protector location ’ (714) 917-1333 (800) 257-3526 FEATURES ...

Page 27

... Insulation resistance Materials Body housing PBT (Polybutylene Terephtalate) UL-94 VO Terminals Tin plated brass Contacts Gold plated silver Approvals Temperature indicating and regulating UL873, CUL (CSA File No. E145478(S), XAPX2 C-UL File No. E145478(S), XAPX8 VDE File No. E-14713 RoHS Compliant ’ (714) 917-1333 (800) 257-3526 ...

Page 28

... X-ray and visual inspection of the TCO will determine if the fuse body has been damaged. c. Note that the TCO body is electrically live and must be insulated before applying a metal clamp over the TCO body. d. Care should be used when pushing the epoxy end lead to avoid the lead 12 14 16A being forced into the TCO body ...

Page 29

... Hydraulic systems Selco probe thermostats are thermally sensitive bimetallic switches which when reaching a fixed factory set temperature, either opens or closes to break or make an electrical circuit. They reset automatically on cooling. Some devices can be used as controlling thermostats which cycle open and close more rapidly to maintain temperature level. Other devices ...

Page 30

... Room Temperature - 525ºF ± 20ºF S200-A-1325 Room Temperature - 425ºF ± 20ºF S200-A-2051 Room Temperature - 205ºF ± 10ºF S200-F-1 Room Temperature - 575ºF ± 25ºF * Temperature calibration service is available - consult Selco for details ** Turn clockwise to increase temperature setting ’ (714) 917-1333 (800) 257-3526 & The S200 Series thermostats have a base plate with a high coefficient of expansion ...

Page 31

... These bimetal thermostats are available in adjustable or fixed settings. The position of the adjustment shaft determines the desired temperature. Contacts are “snap-action” which extends the electrical life or “creep-action” which carry no built in differential. They are primarily used in irons, grills, small electric ovens, as well as commercial and industrial heating devices ...

Page 32

... The WS Series has a combined function of refrigerator cycling control and manual defrosting with a push button shaft in the center of the adjusting shaft. Defrost starts when the push button is pressed, and it terminates automatically as temperature rises to a pre-set point. Then the unit continues its normal running cycle. ...

Page 33

... SPST or SPDT. There is a narrow differential and a forced off function. Series can be used in DC current with inductive loads. Fixed operating temperatures (without shaft) ar also available. With universal adaptability in mind, the WK and WK-H Series ...

Page 34

... Terminal No and 3 - are the same direction as capillary Terminal No and 7 - are the opposite direction Ground Terminal No and 5 - are in the front of the bracket Ground Terminal No and 7 - are in the rear of the bracket FAX (714) 917-1355 www ...

Page 35

... E-mail: sales@selcoproducts.com 250V, 6 Amps, 50Hz 250V, 6FLA, 36LRA 120V, 10FLA, 40LRA -25ºF to 42ºF (-32ºC to 6º 18K 2.7ºF (1.5ºC) at calibration point 3.6ºF (2.0ºC) at non-calibration point <50m S >100M S AC 50/60Hz, 1500V/1 minute UL, C-UL, VDE Typical Function Chart ...

Page 36

... Version 30K Version 15K Version 14K Version 25K 2.7ºF (1.5ºC) at calibration point 3.6ºF (2.0ºC) at non-calibration point <50m S >100M S AC 50/60Hz, 1500V/1 minute UL, C-UL, VDE 3-4 Main switch closes at temperature rise ...

Page 37

... OFF position and the normal ON/OFF operation of the temperature control is reset. Defrost function can be initiated in any position of the dial shaft. If initiated in error, the defrost function can be cancelled by turning the dial shaft to the OFF position. Terminal 3-4: Closes on temperature rise Electrical ratings ...

Page 38

... Typical Electrical Wiring Diagram 3-4 Main switch closes at temperature rise 3-6 Signal switch closes at temperature rise C Compressor S1 Warning lamp indicates to high temperature FAX (714) 917-1355 E-mail: sales@selcoproducts.com 250V, 50Hz Terminal 3-4: 6 Amps Terminal 3-6: 0.1 Amps -40ºF to 104ºF (-40ºC to 40º 30K ...

Page 39

... WXN005 WKP003 KP006 KP007 WAN002 WXN002B WLD001 BT001 WLD007 WLD008 ’ (714) 917-1333 (800) 257-3526 www.selcoproducts.com WKP004 WKP005 WKB001 XN001A WZJ001 WWZ001 BT001 JT002 JT001 FAX (714) 917-1355 E-mail: sales@selcoproducts.com KP002 XN001 JD702 WDJ001 ...

Page 40

... SPST or DPST. or adjustable temperatures with or without auxiliary switches and/or pilot-duty ratings are available on special order. The SJW model includes a mechanical “positive off” feature in the dial “off” position. A variety of control knobs and bezels are available upon request. ...

Page 41

... Model SJW ’ (714) 917-1333 (800) 257-3526 Model SJQ D.P.S.T. - Normally closed, open on temperature rise Amps, 250 Volts Model SJW D.P.S.T. - Normally closed, open on temperature rise Amps, 250 Volts - Positive off switch available upon request FAX (714) 917-1355 www.selcoproducts.com E-mail: sales@selcoproducts.com ...

Page 42

... Selco’s bulb and capillary thermostats have a fluid filled bulb. When temperature rises, the bulb fluid expands via a capillary tube to an expandable diaphragm within the remote thermostat set point. The thermostats are compact and have ceramic bodies. Accessories include knobs and dials that allow selection of the temperature set point ...

Page 43

... Standard Mechanical Specifications Max. Ambient Max. Working Temperature Exposure of Temperature of Ranges Thermostat Case º ...

Page 44

... The circuit will remain inactive until the thermostat is reactivated by manually depressing the reset button. Selco CAP-MR Series meets the requirement of U.L. trip-free device where the circuit remains open while the manual reset is held depressed. ...

Page 45

... & Selco’s line of Bulb & Capillary thermostats come complete with a variety of brackets, terminals, dial plates, knobs and adjustment shaft options to accommodate a wide range of installation requirements. Custom printing available. 2266A/68-118 CAP-XXX-KNOB-1 (model shown with bezel) 2302L Models available from stock - subject to availability ...

Page 46

... Additionally, with Selco’s volume purchasing of these small speciality items, customers eliminate paying premium prices. Call to today to find out how Selco can eliminate the hassle of assembly and purchasing details that end up costing valuable time and money. ...

Page 47

... Potted with epoxy in a polyimide tube Compatible with YSI 400 and 700 temperature monitor instruments Life Sciences & Micro Temperature Probes (LSMC Series) 0.0185” and 0.0190” maximum diameter - capability to .0175” dia. Fast response accuracy to ±0.1°C Potted with epoxy in a polyimide tube ...

Page 48

... For maximum versatility, users can select from power input options of 115 VAC or 230 VAC, with Class 2 Isolation Transformer. Further flexibility is provided via the onboard POT or connector that can optionally be used with input signals such as humidity, pressure, or other. Model 2699 has all the same features as Model 2698, however, includes up to three outputs and onboard bi-color LED indicator ...

Page 49

... The FCM (Feature Configuration Module) offers original equipment manufacturers the ability to inventory one controller that is capable of controlling different model appliances that they manufacture. The FCM connects to the controller and communicates with the processor to select configuration data from a pre-established list of parameters and parameter values in the software. ...

Page 50

... Five operating modes provide the user with a great degree of flexibility from the time only control or simultaneous temperature and time control ...

Page 51

... Selco/ECC Model 2830 Digital Timer is a One-Shot or Delay On-Make timer with a built-in SSR solid state output. There are two settings allotting timing ranges from minutes, and from seconds. Contact Selco/ECC for further application requirements ’ (714) 917-1333 (800) 257-3526 ...

Page 52

... An optional panel mount LED indicates that dispensing is in progress. The start button can either be connected to the AC line for 110/220 VAC activation or if low voltage is desired, the button can be connected straight to the board. ...

Page 53

... Additionally, using the SST in new product designs eliminates the need for the input voltage range management and can reduce inventory of the finished good. Featuring high energy efficiency, the SST uses much less power at no load than conventional transformers, and provides energy savings and an improved safe-guard against brown-outs ...

Page 54

... Standardizing on this one versatile timer, the user can stock a single part that can handle all time delay control functions. Conversion from a Delay-On-Operate to Interval-On (or any of ...

Page 55

... Interval-On - Upon application of power to the input terminals, the output contacts transfer immediately and the timing period begins. At the completion of the preselected time delay, the output contacts de-energize. Reset is accomplished by removal of the input power ’ ...

Page 56

... Standard DIN cutout (72mm) UL recognized and CSA certified 120 VAC operation; 50/60Hz Remote input with interlock capability Minutes & seconds or hours & minutes Selco/ECC’s CDT Series (part number: 8322-2398-2000) has been designed to be panel mounted through a 72mm-square DIN cutout. All connections are via the back of the unit by way of 1/4” ...

Page 57

... PBT: Polybutylene Terphtalate Phenolic: An insulating thermo-set plastic used for the body of specific thermostats Set point: Operating temperature; temperature at which the disc changes its curvature (snaps) to open or close electrical contacts SPST (Single pole, single throw): One set of terminals to activate or deactivate a circuit SPDT (Single pole, double throw): An electrical switch capable of controlling two different circuits ...

Page 58

... One year on most products. Seller extends the same warranties to buyer as the manufacturer extends to seller. All other warranties, whether expressed or implied, are hereby disclaimed except as set forth herein the buyer’s sole responsibility to specify and determine the suitability of a particular control or component based on their unique individual applications and requirements. ...