405A100F2X ATC Diversified Electronics, 405A100F2X Datasheet

no-image

405A100F2X

Manufacturer Part Number
405A100F2X
Description
Relay; E-Mech; Timing; On Delay; SPDT; Cur-Rtg 10A; Ctrl-V 24-240/24AC/DC; Socket Mnt
Manufacturer
ATC Diversified Electronics
Datasheet

Specifications of 405A100F2X

Brand/series
405A Series
Contact Form
SPDT
Current, Rating
10 A
Function
Timing
Mounting Type
Socket
Number Of Pins
8
Power, Rating
240 VA
Relay Type
Electro Mechanical
Standards
cULus, CSA, CE
Termination
Plug-In
Timer Type
On Delay
Timing Range
1 or 10 sec.⁄min.⁄hrs.
Voltage, Control
240⁄24 VAC⁄VDC
Voltage, Rating
250⁄30 VAC⁄VDC
Timing Ranges
1 and 10 Sec, Min., Hours
Universal Power Supply
24-240 VAC and 24 VDC
<
Downloadable Files:
Marsh Bellofram Group of Companies
405A Series
Product Detail:
Instantaneous & Delayed: A version of the 405A is available with one set
of SPDT instantaneous contacts and one set of SPDT delayed contacts. The
instantaneous contacts transfer as soon as the timer is powered. The
delayed contacts transfer at time out. This contact arrangement can be
used to replace many conventional timers.
On Delay/Interval Timing Mode Version: A version of the 405A is available
with selectable On delay or Interval timing modes. This version has a set
of DPDT output contacts. When in the On delay mode, the contacts
transfer at time out. When in the Interval mode, the contacts transfer
when power is applied and release at time out.
Universal Power: All 405A timers can be powered using 24-240 VAC or 24
VDC power, greatly simplifying ordering and inventory management of
replacement units.
1/16 DIN Housing: The 48mm
watertight when panel mounted. The 405A is mounted in an 8-pin round
(octal) socket. With an optional mounting clip, the 405A can be panel
mounted.
The Dial on the 405A is extra large and is easy to read. When fractional
ranges are selected, decimal points are clearly indicated.
The Mode select and Range select switches are located on the side of the
unit, so that when panel mounted, these switches are not accessible to the
operator. This tamper proof feature prevents unauthorized or hazardous
changes to the timing mode and range from being made.
Cycle Progress Indication: The 405A LED indicator provides a unique
and effective method of cycle progress indication. Off before timing, the
LED blinks at an ever increasing rate as the cycle progresses: once every
3-1/2 seconds during the first 10% of the cycle, twice during the second
10%, and so on. At time out, the LED pulses at a high rate. (In the 1, 5,
10 and 50 second ranges, the LED is Off before timing, steady On during
timing, and pulsing On after time-out).
Part Numbers:
<
Automatic Timing & Controls
On-Delay version with instantaneous relay
Selectable On-Delay/Interval Timing Mode version
Output Contacts rated 10A 120/240 VAC and 30VDC
Six Timing Ranges in a single unit
Timing Ranges:
1 and 10 sec., min., and hours
5 and 50 sec., min., and hours
Universal Power Supply: 24-240 VAC and 24 VDC
48mm
Large and easy to read dial shows decimal points
Round (octal) socket mount or mount in panel cutout
Watertight when panel mounted
Range and Mode select are tamper proof when panel mounted
Unique flashing cycle progress indication
2
DIN Standard housing
405A Timer with Instantaneous Relay
2
<
(1/16 DIN) housing is compact and is
Timer
< 405A Series
Purchase Details:
Product Contact:
Specifications:
Models
Contact
Rating
Contact
Material
Temperature
Rating
Noise
Immunity
Mounting
Sales Contact
405A100F1X
405A500F1X
405A100F2X
405A500F2X
Both models available in 6
ranges from 1 sec. to 10
hrs. or 5 sec. to 50 hrs.
Rated 10 AMPS resistive at
30 VDC or 250 VAC (or
less)
1/8 HP @120 VAC
1/4 HP @ 240 VAC
240 VA @ 240 VAC
LIFE: 10 million operation
with no load 100,000
operations with: 10 AMPS
at 30 VDC (or less) or 10
AMPS at 250 VAC (or less)
Silver Cadmium Oxide
0 to 122°F (-18°C to 50°C)
Showering ARC per NEMA
ICS 2-230. In addition, the
405A will withstand a
voltage surge of 4500 volts
for 50 µsec. without
damage.
Plug-in octal base; mounts
in any position with
retaining clip.
Options
Technical Contact
On Delay w/
instantaneous
& delayed
relays (1 or
10 SEC/MIN/
HRS)
ON-Delay w/
instantaneous
& delayed
relays (5 or
50 SEC/MIN/
HRS)
ON-Delay/
Interval with
(1) DPDT
relay (1 or 10
SEC/MIN/
HRS)
ON-Delay/
Interval with
(1) DPDT
relay (5 or 50
SEC/MIN/
HRS)
Surface
mounting
socket
DIN rail
mounting
socket
Panel-
mounting
adapter kit
Plug-on
socket kit

Related parts for 405A100F2X

405A100F2X Summary of contents

Page 1

... SEC/MIN/ HRS) ON-Delay w/ instantaneous & delayed 405A500F1X relays ( SEC/MIN/ HRS) ON-Delay/ Models Interval with (1) DPDT 405A100F2X relay ( SEC/MIN/ HRS) ON-Delay/ Interval with (1) DPDT 405A500F2X relay ( SEC/MIN/ HRS) Both models available in 6 ranges from 1 sec hrs sec hrs. Rated 10 AMPS resistive at ...

Page 2

Options: Accessories 8-Pin surface/DIN rail socket Hold down for above socket Panel mounting bracket Plug-in socket kit (8-pin) 8-Pin panel socket w/rear facing terminals • Bellofram Precision Controls • Marsh Instruments Create Part Number >>>>> 405A Six dial-selected ranges (1 ...

Page 3

ON-Delay version with instantaneous relay • Selectable ON-Delay/Interval Timing Mode version • Output Contacts rated 10A 120/240 VAC and 30 VDC • Six Timing Ranges in a single unit • Timing Ranges: 1 and 10 SEC, MIN, and hours ...

Page 4

... SEC/MIN/HRS) ON-Delay w/instantaneous & delayed 405A500F1X relays ( SEC/MIN/HRS) ON-Delay/Interval with (1) DPDT MODELS 405A100F2X relay ( SEC/MIN/HRS) ON-Delay/Interval with (1) DPDT 405A500F2X relay ( SEC/MIN/HRS) Both models available in 6 ranges from 1 SEC to 10 HRS or 5 SEC to 50 HRS Rated 10 AMPS resistive at 30 VDC or ...

Page 5

DIMENSIONS (INCHES/MILLIMETERS) \\\ TYPICAL CIRCUITS 405A...F1X *Minimum Momentary Switch Closure Time — 50 mSEC BEFORE START TIMING TIMED OUT 405A...F2X * For Interval Operation With A Momentary Start Switch, Jumper 7 & 3 For Repeat Cycle ...

Related keywords