H3CA-8H-AC100/110/120 Omron Automation, H3CA-8H-AC100/110/120 Datasheet

no-image

H3CA-8H-AC100/110/120

Manufacturer Part Number
H3CA-8H-AC100/110/120
Description
Relay; SSR; Timing; On Delay; SPDT; Cur-Rtg 3A; Ctrl-V 100/110/120AC; Vol-Rtg 250AC
Manufacturer
Omron Automation
Datasheet

Specifications of H3CA-8H-AC100/110/120

Contact Configuration
SPDT
Contact Form
SPDT
Current, Rating
3 A
Dielectric Strength
1000 VAC, 50⁄60 Hz for 1 Min Between Non-Continuous Contacts, 2000 VAC, 50⁄60 Hz for 1 Min Between Current-Carrying and Non-Current-Carrying Parts and Between Contact and Control Circuit
Function
Timing
Material, Body
Plastic Case
Mounting Type
Socket
Number Of Pins
8
Relay Type
Solid State
Standards
UL, CSA, CE
Temperature, Operating, Minimum
-10
Termination
Plug-In
Timer Type
On Delay
Timing Range
0.1 sec. to 9990 hrs.
Voltage, Control
100⁄110⁄120 VAC
Voltage, Rating
250 VAC
Supply Voltage
100/110/120 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
DIN-sized (48 x 48, 45 x 75 mm) Timer with
Digital Setting and LCD Display
• Dual power supplies for free AC/DC.
• Eight operation modes selectable with one unit.
• Any desired time can be set digitally within a range from 0.1
• Four external signal inputs.
• ON/OFF indicator for control output and bar indicator for
• Conforms to UL, CSA, and CE marking.
Ordering Information
Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8.
■ Accessories (Order Separately)
Note: Track mounted socket can be used as a front connecting socket.
Specifications
■ Time Ranges
A desired time can be set within a range of 0.1 s to 9,990 hrs by combining the three thumbwheel switch modules for time setting and one module
for time unit selection.
Time unit
Time range
Time-limit operation/self-
resetting/external
resetting (see note 2)
Time-limit operation/
self-resetting
H3CA-A
H3CA-8H/H3CA-8
seconds to 9,990 hrs.
remaining time.
Solid-state Timer
H3CA
Operation/resetting
2. The operation/resetting system depends on the selected operation mode. For details, see “Timing Chart”.
3. The 8 operation modes are as follows:
system
Timer
A: ON-delay operation
B: Repeat cycle operation
C: Signal ON/OFF-delay operation (1)
D: Signal OFF-delay operation (1)
1 to 999 (3 digits)
8 operation modes
(selectable)
(see note 3)
ON-delay operation 8-pin round socket DPDT
Operation mode
P2CF-11
P2CF-08
Track mounted socket
0.1 s
11-pin round socket SPDT
Front screw
(See note.)
Terminal
1 s
SPDT
Time-limit
contact
0.1 min
PL11
PL08
Solder terminal
---
---
SPDT
Instantaneous
1 min
contact
E: Interval operation
F: One-shot and flicker operation
G: Signal ON/OFF-delay operation (2)
H: Signal OFF-delay operation (2)
Back connecting socket
0.1 hrs
H3CA-A
H3CA-FA
H3CA-8
H3CA-8H
track mounting
mounting/
P3GA-11
P3G-08
Surface
1 hr
Screw terminal
Mounting
CSM_H3CA_DS_E_2_1
H3CA-A
---
H3CA-8
H3CA-8H
Flush mounting
10 hrs
1

Related parts for H3CA-8H-AC100/110/120

H3CA-8H-AC100/110/120 Summary of contents

Page 1

... ON-delay operation 8-pin round socket DPDT self-resetting Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8. 2. The operation/resetting system depends on the selected operation mode. For details, see “Timing Chart”. 3. The 8 operation modes are as follows: ...

Page 2

... Immunity RF-interference: Immunity Conducted Disturbance: Immunity Burst: Immunity Surge: Immunity Voltage Dip/Interruption Weight H3CA-A: approx. 110 g H3CA-FA: approx. 190 g H3CA-8 100/110/120, 200/220/240 VAC, (50/60 Hz), 24 VDC, 110 VDC (permissible ripple: 20% max.) (See note 1.) AC: approx. 10 VA/1 W DC: approx EN61326 EN55011 Group 1 class A ...

Page 3

... Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.1 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. Note: 1. The H3CA Series has been tested for the following: impulse voltages, noise (via noise simulator, for L loads, and for relay oscillation), and resistance to static electricity. ...

Page 4

... Operation ■ Timing Chart H3CA-A (FA) ON-delay Operation (A Mode) Signal Start t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Flicker Operation (B Mode) Signal Start t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. ...

Page 5

... Set time; t-a: Time within the set time t: Set time Power-ON Start/Power-OFF Reset t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Signal ON/OFF-delay Operation 2 (H Mode) t-a t: Set time; t-a: Time within the set time H3CA 5 ...

Page 6

... Also, while a check signal is being input, the elapsed time measurement of the set time is not performed. ON-delay Operation . 2 Repeat Cycle Operation H3CA t: Set time; t-a: Time within the set time t: Set time; t-a: Time within the set time 6 ...

Page 7

... Terminal Arrangement Mounting Holes (Top View) Note: P2CF-08 can be used as a front connecting socket. H3CA Two,M4 or 4.5 dia. holes Note: When mounting two or more timers in line, dimension L between two adjacent timers should min. Mounting Height of Timer with Socket 108 ...

Page 8

... Terminal Arrangement Mounting Holes (Bottom View) Two, 3.5 dia socket mounting holes Terminal Arrangement Mounting Holes (Bottom View) Two, 3.5 dia socket mounting holes H3CA Mounting Height of Timer with Socket 86.3 10.9 P3G-08 Mounting Height of Timer with Socket Hold-down clip 79.6 ...

Page 9

... Y92A-48B Protective Cover attached, which must be taken into consideration before using the Y92A-48B Protective Cover. When attaching the Y92A-48A to the Timer to be panel-mounted, use the Y92F-30 Mounting Adapter along with the Timer. The Protective Cover cannot be, however, used for the H3CA-FA Series. H3CA 9 ...

Page 10

... Note: 1. *C: Check: 3-4 *G: Gate: 3-5 *S: Start: 3-6 *R: Reset: 3-7 2. Conventional time-limit contacts are symbolized as However, the contacts of H3CA-A are symbolized as because timer has 8 operation modes. ■ Input Connections Signal Inputs Connect the start input contact between terminals C and F, the reset input contact between terminals C and G, the gate input contact between terminals C and E, and the check input contact between terminals C and D ...

Page 11

... Note: Except for the power supply circuitry, avoid the laying of input signal wires in parallel or in the same conduit with high-tension or power lines recommended to use shielded wires or wiring with independent metal conduits for the shortest possible distance. H3CA-8H (-) (+) H3CA-8 (-) (+) H3CA 11 ...

Page 12

... Application Examples Standard type H3CA is used for the following application examples. In the schematic diagrams, each thick the indicates the wiring necessary for selecting the desired operation mode. ON-delay Operation (A Mode) Power-ON Start/Power-OFF Reset (+) or (−) (+) or (−) Flicker Operation (B Mode) Power-ON Start/Power-OFF Reset (+) or (− ...

Page 13

... Interval Operation (E Mode) Power-ON Start/Power-OFF Reset One-shot and Flicker Operation (F Mode) Power-ON Start/Power-OFF Reset Signal Start/Signal Reset (+) or (−) (+) or (−) Signal Start/Signal Reset (+) or (−) (+) or (−) Signal OFF-delay Operation 2 (H Mode) Signal/Instantaneous Operation/Time-limit Reset (+) or (−) (+) or (−) H3CA (+) or (−) (+) or (−) (+) or (−) (+) or (−) (+) or (−) (+) or (−) 13 ...

Page 14

... Although there is a wide range of power connectable to the H3CA-A and H3CA-FA, be sure that there is no inductive voltage or residual voltage applied to the timer power supply terminals (2 and 10 and A2) when the power switch is turned OFF. (Inductive voltage can be generated in the power supply line placed in parallel with high-voltage or power lines ...

Page 15

... Input terminal Circuit Isolation transformer is required. A transformer is not used in the power supplies for the H3CA-A and H3CA-FA. You can therefore receive an electrical shock by touching the input terminals when the power supply voltage is being applied. Take adequate precautions to protect against electrical shock. ...

Page 16

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a ...

Related keywords