MINT1065A2475C01 SL Power ( Ault / Condor ), MINT1065A2475C01 Datasheet

no-image

MINT1065A2475C01

Manufacturer Part Number
MINT1065A2475C01
Description
Power Supply, Medical, Internal, 24V, 65 Watts, 2.70A, 1% Ripple/Noise
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of MINT1065A2475C01

Brand/series
MINT1065A Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 2.7 A
Power, Output
65 W
Primary Type
AC-DC
Voltage, Input
100 to 240 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Total Regulation
Turn-on Time
Hold-up Time
Ripple & Noise
Transient Response
Protection
Voltage
Frequency
Input Current
Input Surge Current 264VAC (Cold start)
Input Fuse
Leakage Current
• Size: 2” x 4” x 1.02”
• <0.5 Watt Standby Power Dissipation
• Meets Energy Star Level IV
• Up to 90% High Efficiency
• Class I Input
• EN60601-1 Medical Approval
MINT1065A
65 Watt Single Output Series
Medical - Universal Input Power Supply
International Safety Standard Approvals
Specifications
Output Specifications
Input Specifications
(Line and Load)
Over Current Protection
Short Circuit Protection
Over Voltage Protection
Over Temperature Protection Option
UL/IEC127
100-240VAC, +/-10%
47-63Hz
1 .5A – 0.7A @ 100VAC
– 240VAC
40A max.
T2.5A, 250V
< 300uA @ 264VAC @ 60Hz,
normal
<500uA @ 264VAC @ 60Hz,
single fault condition
+/- 2%
< 2 sec
>17 msec min. from loss
of AC input at full load,
nominal line (120VAC/60Hz)
1 % p-p max. with 20MHz
BW
5 00 us typical to 0.5% for
50% step, di/dt< 0.2 A/us,
max 3.5% deviation
Hiccup mode
Hiccup mode
Built-in
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
Shock & Vibration
Random Vibration
Shock
Efficiency
Switching Frequency
Isolation voltage
Approvals and
Standards
2 Year Warranty
Environmental Specifications
General Specifications
0%-95%
Operating
Non-Operating
Operating
Non-Operating
Operating
Non-Operating
Input/Output
Input/Earth
Output/Earth
Safety
0 -40° C full load and 40-70° C ac-
cording to the derating curve
-40 to 85° C
-500 to 10,000 ft. MSL
-500 to 40,000 ft. MSL
C onvection - non vented case
0 .003 g2/Hz, 1.5 grms overall,
3 axes, 10 min. / axis
0 .026 g2/Hz, 5.0 grms overall,
3 axes, 1 hr. / axis
H alf-sine, 20 gpk, 10 ms, 3 axes,
6 shocks total
H alf-sine, 40 gpk, 10 ms, 3 axes,
6 shocks total
Up to 90% Typical
Variable 50-75 kHz Typical
4000VAC
1800VAC
500VAC
EN/IEC/UL 60601-1,
CSA 22.2 No. 601-1

Related parts for MINT1065A2475C01

MINT1065A2475C01 Summary of contents

Page 1

MINT1065A 65 Watt Single Output Series Medical - Universal Input Power Supply • Size: 2” x 4” x 1.02” • <0.5 Watt Standby Power Dissipation • Meets Energy Star Level IV • 90% High Efficiency • Class I ...

Page 2

... MINT1065A 65 Watt Single Output Series Medical - Universal Input Power Supply Medical Voltage Model Output MINT1065A1275C01 12V MINT1065A1575C01 15V MINT1065A1875C01 18V MINT1065A2475C01 24V MINT1065A4875C01 48V Condor Part Number Key Medical Internal Standard Factory Location General Specifications (continued from p. 1) MTBF Dimensions Weight ...

Page 3

MINT1065A 65 Watt Single Output Series Medical - Universal Input Power Supply Mechanical Specifications CLASS I Input ...