MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 104

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
5-4
3-Phase Voltage Monitor
Model 240T6
FEATURES
Operating Logic: This control continuously
monitors 3-phase power lines for abnormal
conditions. When properly adjusted, the
control will detect:
If none of the above conditions are present,
the control will energize the internal relay
and the indicator light will be green. When
any of the above faults are detected, the
indicator light will turn yellow for approxi-
mately 3 seconds warning that the relay is
about to de-energize. After the delay time
the relay will de-energize and the indicator
light will turn red. When the fault is correct-
ed, the monitor will automatically reset by
energizing the relay and the indicator lamp
will be green. Should the fault be corrected
during the delay time, the monitor will not
de-activate the relay and the indicator will
again be green.
Adjustment: Apply 3-phase power with-
in operating range to the monitor (phase
sequence must be observed). Turn adjust-
ment to maximum clockwise position.
Indicator lamp will be illuminated red after
the delay time. Slowly turn counterclock-
wise until indicator changes to green (relay
will activate). If voltage is nominal, setting
should be correct.
Note: If phase sequence is incorrect, the monitor will not activate.
Reverse any two input leads and readjust as described above.
100% functionally tested
Low cost
Tri-color status LED
3 second fault delay timer
Line voltage setpoint adjustment range:
160 VAC to 240 VAC
50/60 Hz operation
SPDT 10 A relay output
Convenient plug in package
Phase loss on a loaded motor, regard-
less of regenerated voltage
Low voltage on all phases
Very low voltage or loss of any single
phase
Phase reversal
VOLTAGE MONITORS
File #E59090
ORDERING INFORMATION
SPECIFICATIONS
SETPOINT
Adjustment: Single turn potentiometer for adjust-
ing nominal voltage
Range:
160-240 VAC 60 Hz LO to HI
180-240 VAC 50 Hz LO to HI
Accuracy:
Min. Setting (Max. CCW): Must operate (green
light) at 160 VAC, 60 Hz (180 VAC, 50 Hz) line to
line
Max. Setting (Max. CW): Must drop out (red light)
at 240 VAC 50/60 Hz line to line
Hysteresis: 2% typical
Fault Delay Time: 2 to 4 sec.
INPUT
3 Phase Operating Voltage: Three wire connec-
tion, no neutral required
160-240 VAC, 277 VAC max. line to line 60 Hz
180-240 VAC, 277 VAC max. line to line 50 Hz
Power Consumption: 3 W max. at 277 VAC line
to line exclusive of load
Frequency: 50/60 Hz
OUTPUT
Contact Type: Relay SPDT (1 form C)
Rating: 10 A max. resistive, 1/3 hp, 345 VA,
120/240 VAC
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
Display: 1 tricolor LED
Green indicates status OK
Yellow indicates fault condition imminent
Red indicates fault condition
PROTECTION
Transient Voltage: protected by three 30 joule
metal oxide varistors
Dielectric Breakdown: 1500 V RMS minimum at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin plug
Mounting: Socket mount, part number
MSO-0008P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C
8-pin circular socket, DIN rail
mountable
VOLTAGE RANGE
160 to 240 VAC
ACCESSORY
MSO-0008P-012
PART NUMBER
PART NUMBER
PLC-240T6-44T
3 PHASE VOLTAGE MONITOR
PIN CONFIGURATION
MODEL: PLC-240T6-44T
INPUT VOLTAGE: 160-240 VAC
TRICOLOR LED
WEST CHICAGO, IL. 60185
LO
Normal
Green
F
A
R
F
3
2
B
CONTACTS:
10AMP,1/3HP,345VA,
120/240VAC
N
C
VOLTAGE
1.770
(45.0)
ATIONAL CONTROLS
ORPORATION
1
Yellow
Fault
Delay
LINE
2.935
(74.5)
3.650 MAX
4
R
(93.0)
3 , 60 HZ
F
8
5
Fault
Red
F
C
6
7
HI
(13.26)
.522

Related parts for MSO-0008P-012